In chemical processing, energy, water treatment, food equipment, and automated production lines, pressure transmitters often need to remain in long-term contact with liquids, gases, steam, or media containing particulate matter. Even when housings, process connections, and diaphragms are made of stainless steel, this does not mean they can remain stable over the long term in all environments. Surface roughness, the integrity of oxide films, welding heat-affected zones, and residual contaminants can all alter the metal's resistance to corrosive media.
The core purpose of surface treatment for stainless steel pressure transmitters is to reduce surface defects and deposits, restore or strengthen the passive film, and improve cleanability and corrosion resistance. For pressure measurement equipment, surface condition is not only related to appearance; it may also affect process connection sealing, hygienic cleaning, zero stability after diaphragm erosion by media, and subsequent maintenance frequency.
Taking common industrial operating conditions as an example, ordinary circulating water environments have relatively low requirements for surface processing; media containing chloride ions, acid and alkali solutions, humid salt spray environments, and high-temperature steam environments increase the risks of pitting corrosion, crevice corrosion, and stress corrosion. Focusing only on grades such as 304 or 316 during procurement while overlooking surface treatment quality can easily result in rust spots, connection corrosion, or measurement drift after several months of operation.
Xi'an Shenghongchuang Instrumentation Co., Ltd. and its production base, Shaanxi Qinkong Sensor Technology Co., Ltd., provide products including pressure, level, differential pressure, temperature and humidity, weighing, displacement, and flow measurement products for industrial automation measurement and control applications. For different media and installation environments, the material, diaphragm structure, sealing method, and surface treatment method of a pressure transmitter should be jointly confirmed as part of a complete selection solution.
Mechanical polishing removes machining marks, burrs, and localized oxide layers through abrasive belts, polishing wheels, or grinding materials, making the stainless steel surface smoother. When used on pressure transmitter housings, flanges, threaded fittings, and similar parts, appropriate polishing can reduce dirt accumulation, improve appearance consistency, and facilitate the timely identification of leakage and corrosion marks during routine inspections.
Brushed finishes usually retain fine, consistently oriented textures, providing a stable visual effect and making them suitable for instrument housings and control cabinet installation applications. However, brushing is not a corrosion-resistance enhancement process. If the texture is too deep, iron filings are introduced during processing, or subsequent cleaning is inadequate, localized rusting may still occur in humid environments. Therefore, whether cleaning and passivation are performed after brushing is more important than simply pursuing appearance.
For media-contact parts with sanitary-grade or high-cleanliness requirements, surface roughness is generally of greater concern. In engineering, the Ra value is commonly used to assess surface smoothness. The lower the Ra value, the less likely residual liquid, particles, and scale deposits are to adhere. General industrial process connection areas can be controlled according to actual requirements, while food, pharmaceutical, or high-purity media piping should confirm lower roughness requirements for diaphragms and wetted structures.
Inspection should focus on areas near welds, thread roots, flange sealing faces, and diaphragm edges. Due to concentrated machining stress, uneven polishing, or insufficient cleaning, these areas can easily become starting points for corrosion. For diaphragm seal pressure transmitters, it should also be confirmed that the diaphragm surface has no scratches, indentations, or abnormal abrasion marks.
It should be noted that a mirror finish does not necessarily mean higher corrosion resistance. If unsuitable abrasives are used during polishing, or if tools are shared among workpieces of different materials and cause iron ion residues, “flash rust” may occur during subsequent use even if the surface is bright. Therefore, mechanical treatment must be combined with degreasing, cleaning, and necessary passivation processes.
For bulk procurement projects, the technical agreement can specify the surface condition of wetted parts, roughness requirements, weld treatment requirements, and appearance acceptance standards. Defining these requirements at the order stage is more conducive to quality control than relying solely on visual inspection after equipment delivery, and it can also reduce rework and downtime risks.
Pickling is mainly used to remove oxide scale, weld discoloration, oil residues, and contaminants such as free iron from stainless steel surfaces. Passivation promotes the formation of a stable, dense chromium-rich oxide film on the surface through chemical action. For stainless steel components that have undergone welding, cutting, sandblasting, or thermal processing, pickling and passivation are usually important processes for restoring corrosion resistance.
For pressure transmitter process connections, impulse pressure fittings, flange structures, and housing components used in high-humidity, high-salt-spray, or chemically corrosive environments, standardized pickling and passivation can significantly reduce the likelihood of early surface rusting. However, diaphragms, electrical connectors, and internal sensing elements cannot simply use the same treatment method and must be controlled separately according to component structure and process limits.
Thorough rinsing and drying after pickling and passivation cannot be omitted. If acid solution remains in threads, crevices, or weld depressions, it may instead cause subsequent corrosion. During acceptance, customers can check for obvious color differences, residual liquid marks, spots, and odors on the surface, and request the supplier to provide corresponding material and process quality records.
Electropolishing uses electrochemical principles to preferentially remove microscopic protrusions from metal surfaces, making the surface more uniform and smooth. Compared with mechanical polishing alone, it provides more noticeable improvement in fine burrs, machining textures, and localized defects. It is therefore commonly used for instrument wetted parts with high requirements for cleanliness, corrosion resistance, and media residue control.
In food and beverage, pharmaceutical purified water, fine chemical, and certain semiconductor auxiliary systems, deep grooves on media-contact surfaces can easily retain residues during cleaning. Electropolished 316L diaphragms or sanitary process connection structures are generally more conducive to CIP cleaning and long-term hygienic management, but actual media temperature, concentration, and cleaning agent composition must still be considered.
Electropolishing is not a necessary configuration for all pressure transmitters. For ordinary pump outlets, air compressor pipelines, building water supply systems, and general mechanical equipment, appropriate conventional surface treatment can usually meet application requirements. Matching the treatment grade to actual risk is necessary to achieve a reasonable balance between corrosion protection reliability and procurement cost.
Sandblasting can remove oxide layers, old coatings, and surface deposits while creating a uniform matte texture. In the manufacture of pressure transmitter housings, metal brackets, or protective covers, a sandblasted surface is beneficial for subsequent coating or marking adhesion. However, for diaphragms and sanitary sealing surfaces in direct contact with media, rough sandblasted surfaces are generally not the preferred option.
The cleanliness of blasting media is crucial. If abrasives containing iron impurities are used, or if equipment is not isolated from carbon steel processing areas, contaminant particles may remain on stainless steel surfaces and subsequently form rust spots in humid environments. Therefore, after sandblasting, cleaning, passivation, or other post-treatment should be performed according to the component's intended use. Sandblasting must not be regarded as the final corrosion-protection process.
For pressure transmitters installed outdoors, in coastal areas, or in chemical plant zones, housing surface processing must also be considered together with the protection rating, wiring method, and installation location. Even if the housing is made of stainless steel, issues such as water accumulation at cable entries, dissimilar metal contact at brackets, and aging sealing rings can weaken overall weather resistance.
304 stainless steel offers good general corrosion resistance and is suitable for most dry environments, ordinary water media, and conventional industrial equipment. For projects sensitive to budget and with low corrosion risk, 304 pressure transmitters provide good cost performance. However, in salt spray, chlorinated water, acid pickling wastewater, or humid coastal areas, conventional surface polishing alone cannot compensate for differences in material corrosion resistance.
Because it contains molybdenum, 316 stainless steel offers better resistance to certain chloride environments and chemical media. Combined with standardized pickling and passivation treatment, 316 pressure transmitters are generally more suitable for chemical equipment, outdoor installations near the sea, circulating water systems, and moderately corrosive media. However, when temperature rises or chloride ion concentration increases, pitting corrosion risk should still be evaluated rather than simply assuming that 316 can cover all corrosive operating conditions.
The main difference between 316L and 316 is its lower carbon content. For diaphragm structures, flange connections, and customized impulse pressure components requiring welding, 316L generally offers greater resistance to intergranular corrosion after welding. During technical evaluation, the question of “what is the difference between 316 and 316L pressure transmitters” should be addressed based on specific conditions, including whether wetted parts are welded, whether they undergo high-temperature processing, whether sanitary-grade surfaces are required, and long-term corrosion risks.
From a cost perspective, higher material grades, electropolishing, sanitary connections, and special sealing components all increase the unit purchase price of equipment. However, if a single site shutdown could result in production line losses, media leakage risks, or frequent disassembly and maintenance, higher-grade wetted materials and surface treatments often deliver better total lifecycle cost performance. Procurement approval should compare initial price, maintenance intervals, and failure costs at the same time.
During incoming acceptance, first verify the nameplate measuring range, output signal, power supply method, process connection, and protection rating, then inspect whether the stainless steel surface is uniform. Pay particular attention to diaphragms, threads, welds, flange sealing faces, and areas around cable connectors to avoid obvious scratches, pits, rust spots, residual polishing compound, or chemical cleaning marks.
During on-site maintenance, it is not recommended to use chlorine-containing bleach, strongly corrosive cleaning agents, or carbon steel wire brushes directly on stainless steel pressure transmitters. For routine maintenance, cleaning methods compatible with the medium and sealing materials may be used. After cleaning, promptly wipe or blow dry the equipment, especially to prevent long-term water accumulation in process connections, cable entries, and installation bracket gaps.
For high-speed pressure fluctuation applications, surface treatment cannot replace proper dynamic performance selection. Response time requirements for high-speed pressure transmitters should be confirmed together with pressure pulsation frequency, acquisition cycle, control system refresh rate, and the installation impulse pressure path. Excessively long impulse lines, blocked damping structures, or improper damping settings can all cause delayed actual response.
Before finalizing a project, it is recommended to provide Xi'an Shenghongchuang with the medium name, concentration range, operating temperature, maximum pressure, connection specifications, installation location, output signal, and explosion-proof or protection requirements. Confirmation by technical personnel based on 304, 316, and 316L material selection, surface treatment processes, diaphragm structure, and sealing solutions can enable a pressure transmitter configuration that better meets on-site requirements in terms of accuracy, stability, corrosion resistance, and procurement cost.