News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

What Requirements Should Be Considered When Selecting a Food-Grade Sealed Level Sensor?
Added to Favorites:125

Food-Grade Sealed Level Sensors: Key Selection Factors from Hygiene Compliance to Stable Operation

In the storage and transportation of beverages, dairy products, condiments, fermented products, and food raw materials, level measurement equipment not only performs inventory measurement and process control tasks, but also directly affects cleaning efficiency, cross-contamination risks, and batch quality traceability. Media used in food production are often adhesive, corrosive, prone to foaming, or subject to high-temperature cleaning. Even if ordinary industrial level sensors provide normal initial readings, seal aging, material leaching, or hygienic dead zones may create long-term risks.

A food-grade sealed level sensor is not simply a product labeled “stainless steel” on its housing. Its core lies in the wetted materials, structural smoothness, seal resistance, hygienic grade of the connection, and the compatibility between the measurement principle and operating conditions. For quality control and safety management personnel, selection should be based on the actual cleaning procedures of the production line, medium temperature, tank pressure, and control accuracy to establish verifiable and traceable technical standards.

Xi'an Shenghongchuang Instrumentation Co., Ltd., supported by the production base of Shaanxi Qinkong Sensor Technology Co., Ltd., can provide level transmitters and supporting intelligent digital display control instruments for standard storage tanks, hygienic vessels, and complex automation systems. For food industry applications, project discussions should first clarify wetted-part requirements, output signals, installation dimensions, and cleaning conditions, rather than making single-factor comparisons based only on measuring range or price.

I. Food-Grade Sealing Should Not Be Judged by Appearance Alone

Wetted Materials Determine Corrosion Resistance and the Foundation for Cleanliness

Acids, salts, sugars, and proteins in food liquids affect materials differently. For standard media such as water and beverage bases, 316L stainless steel generally offers good corrosion resistance; for salty seasoning liquids, acidic juices, or chlorine-containing cleaning environments, the material composition, surface condition, and media contact time require further confirmation. 304 and 316L must not be treated as simply equivalent, nor should a coated housing be used as a substitute for genuine wetted materials.

The roughness of the sensor's wetted surface affects residue adhesion. The smoother the surface, the more easily cleaning solutions can cover it, and the less likely microorganisms and protein residues are to accumulate. For positions with high hygiene requirements, attention should be paid to the continuity of diaphragms, weld seams, process connections, and seal grooves to avoid steps, blind holes, and gaps that are difficult to rinse.

In addition to metal components, sealing rings are also critical wetted parts. Common materials such as EPDM, FKM, and silicone rubber differ in temperature resistance, acid and alkali resistance, oil and grease resistance, and steam resistance. For example, processes involving frequent hot-water or steam cleaning should verify the compression set of seals after high-temperature cycles, rather than considering only room-temperature conditions.

Material Items Recommended for Specification in the Technical Agreement

Item to ConfirmKey Considerations for Food ProductionAcceptance Recommendations
Wetted Metal PartsCorrosion-resistant, cleanable, and free from abnormal leachingSpecify 304 or 316L requirements and material certification
SealsTemperature-resistant, media-resistant, and CIP-cleaning-resistantConfirm the seal material and applicable temperature range
Welding and DiaphragmMinimize liquid retention, cracks, and hygienic dead zonesVerify structural drawings and wetted surface process specifications

II. The Sealing Structure Must Accommodate Cleaning, Temperature, and Pressure

CIP and SIP Conditions Amplify Structural Differences

Food factories commonly use CIP cleaning, while some processes also involve SIP steam sterilization. Thermal expansion and contraction, chemical cleaning agent flushing, and pressure fluctuations during cleaning continuously test sensor diaphragms, sealing rings, and cable outlets. If equipment is suitable only for media at ambient temperature and pressure, installation on tanks subject to frequent cleaning often results in issues such as zero drift, liquid ingress, or seal cracking.

When selecting a model, the maximum operating temperature and cleaning temperature should be confirmed separately. The normal medium temperature may be only 20°C to 60°C, while short-term hot-water cleaning may exceed 80°C, and steam sterilization conditions are even higher. The sensor's temperature resistance rating must cover the actual peak temperature and include a reasonable margin; orders must not be based solely on daily production temperatures.

Pressure conditions are also easily overlooked. Sealed storage tanks may have gas-phase pressures from 0.1MPa to 0.6MPa, and both liquid hydrostatic pressure and tank pressure act on the measuring element. Before using a submersible level transmitter, hydrostatic level transmitter, or differential pressure measurement solution, confirm whether tank pressure compensation is required to prevent significant display fluctuations when the level changes only slightly.

For hygienic connections installed from the top, priority should be given to clamp dimensions, flange standards, and sealing gasket compatibility. When the process connection does not match the tank opening, temporary adapters may create liquid accumulation areas, and the subsequent cleaning and validation costs are usually much higher than the cost of proper initial selection.

III. Select the Measurement Principle According to the Medium and Vessel

Accuracy, Foam, and Adhesion Require Comprehensive Evaluation

The nominal accuracy of a level sensor is not the only evaluation criterion. For batching tanks, level error affects dosing ratios; for storage tanks, stability and repeatability are more important; for foam-rich fermentation liquids or carbonated beverages, the impact of the foam layer on non-contact measurement must be assessed. A suitable solution should first define the control objective and then determine the measurement principle.

Hydrostatic level transmitters are suitable for liquids with relatively stable density, and their level calculation is directly related to medium density. With water as the reference, approximately 10 meters of water column corresponds to 0.1MPa pressure; when medium density varies significantly, corrections are required in range conversion and calibration. For oils, syrups, or mixed liquids, it is recommended to provide a density range rather than a single theoretical value.

For small water tanks, clean-water storage tanks, or applications requiring continuous analog output, 4mA to 20mA signals remain a well-established configuration in automation control. They offer strong interference resistance, and their transmission distance can meet the wiring requirements of most plants; when connected to a PLC or host computer, the supply voltage, load resistance, and shield grounding method should also be confirmed.

Selection Reference for Common Food Level Measurement Conditions

Application ConditionsKey RisksKey Selection Considerations
Drinking Water or Purified Water TanksLow-range fluctuations and limited installation spaceThe measuring range should cover 1.2 to 1.5 times the actual liquid level
Syrup and High-Viscosity MaterialsMaterial buildup, density variations, and difficult cleaningFlush diaphragm structure, cleanable seals, and density correction
Sealed Fermentation or Batching TanksTank pressure, foam, and temperature cyclesPressure rating, maximum temperature, and pressure compensation solution
Edible Oil Storage TanksDensity lower than water and oil residue adhesionCalibrate according to actual density and verify the oil resistance of wetted seals

IV. From Datasheets to On-Site Verification

Installation and Commissioning Determine Long-Term Measurement Quality

Before installation, the actual measurement height, minimum level, maximum level, and alarm points should be confirmed. The sensor range should not be excessively oversized. For example, when the actual level is 0 meters to 2 meters, selecting a 0 meters to 20 meters range reduces effective resolution; generally, a range closer to site conditions can be selected by considering the upper level limit and pressure margin while meeting safety requirements.

For electrical connections, a three-wire 4mA to 20mA level transmitter generally includes a positive power terminal, signal output terminal, and common terminal. Specific definitions must follow the product wiring diagram. Signal cables should be kept away from frequency converters, high-power motors, and high-voltage lines; when shielded cables are used in areas with strong interference, single-end or compliant grounding should be applied according to system requirements to avoid ground loops.

During commissioning, it is recommended to verify at least the empty-tank point, an intermediate level point, and a point near full scale, recording the corresponding display value, current output, and actual level. For equipment with a 0 meters to 5 meters range, linearity can be checked in sections using standard levels or known heights; if continuous fluctuations occur, first investigate bubbles, installation vibration, power supply fluctuations, and signal grounding before determining whether instrument parameters need adjustment.

Establishing a regular inspection system is equally necessary. Connection sealing, diaphragm cleanliness, zero-point trends, and cable sheath condition can be checked according to the production cycle; after replacing cleaning agents, increasing sterilization temperature, or adjusting tank pressure, sensor compatibility should be reassessed. Stable operation is not achieved through a one-time selection, but through a closed loop formed by equipment, process, and maintenance.

V. Food-Grade Level Sensor Procurement Checklist

Clearly Specify All Key Boundary Conditions at One Time

During procurement discussions, it is recommended to provide the medium name, concentration, density, viscosity, temperature range, maximum pressure, tank dimensions, and installation orientation. For media containing particles, prone to crystallization, or with high foam levels, the agitation condition and foam height should also be specified. This information directly affects the sensor range, diaphragm structure, sealing material, and measurement method.

Technical documents should specify the accuracy class, power supply range, output type, protection rating, process connection, and cable length. For example, when on-site connection to a standard control system is required, 24VDC power supply and 4mA to 20mA output can be confirmed; when local monitoring is required, an intelligent digital display control instrument can be used to provide level display, upper and lower limit alarms, or interlocked control.

For batch projects, it is recommended to first use 1 to 2 prototype units to complete verification with the actual medium, cleaning cycles, and continuous operation before determining the configuration for the entire line. Acceptance should not be limited to checking the powered display; it should also verify materials, connections, range, output, sealing condition, and calibration records, ensuring traceable correspondence between product parameters and project requirements.

If sealed level sensors are required for food storage tanks, batching tanks, oil tanks, or cleaning systems, on-site operating condition forms, installation photos, and control requirements can be provided to Xi'an Shenghongchuang. Technical personnel will confirm suitable models based on hygiene grade, measuring range, and cleaning conditions, and prepare clear selection and wiring solutions.

Submit