Pressure Transmitter Manufacturer
Consultation hotline:15529283736
Product Center
—— Product Center ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
Xi'an Shenghongchuang Instrumentation Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
The intelligent electromagnetic flowmeter consists of two parts: a sensor and a converter. It operates based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow of conductive liquids with conductivity greater than 5μS/cm. It is an inductive instrument for measuring the volumetric flow of conductive media. In addition to measuring the volumetric flow of सामान्य conductive liquids, it can also be used to measure the volumetric flow of highly corrosive liquids such as strong acids and strong alkalis, as well as uniform liquid-solid two-phase suspended liquids such as slurry, ore pulp, and paper pulp. It is widely used for flow metering in industrial sectors such as petroleum, chemical, metallurgy, light textile, papermaking, environmental protection, and food, as well as in municipal administration, water conservancy construction, and river dredging.
II,Working Principle
According to the principle of Faraday electromagnetic induction, a pair of detecting electrodes is installed on the pipe wall perpendicular to the axis of the measuring tube and the magnetic field lines. When the conductive liquid moves along the axis of the measuring tube, the conductive liquid cuts the magnetic field lines and generates an induced electromotive force. This induced electromotive force is detected by the two detecting electrodes, and its value is proportional to the flow rate. Its value is:
E=KBVD
Where:
E- induced electromotive force;
K- coefficient related to magnetic field distribution and axial length;
B- magnetic induction intensity;
V- average velocity of conductive liquid;
D- distance between electrodes; (inner diameter of measuring tube)
The sensor uses the induced electromotive force E as the flow signal and transmits it to the converter. After amplification, conversion, filtering, and a series of digital processing, the instantaneous flow and cumulative flow are displayed on a backlit dot-matrix LCD. The converter has 4~20mA output, alarm output, and frequency output, and is equipped with communication interfaces such as RS-485, and supports HART and MODBUS protocols.
III,Instrument Features
Full digital processing, strong anti-interference capability, reliable measurement, high accuracy, and a flow measurement range up to 150:1;
Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage variations, with good EMI resistance;
Adopts a 16-bit embedded microprocessor with fast computing speed and high accuracy, and programmable frequency low-frequency rectangular wave excitation, improving the stability of flow measurement with low power consumption;
Uses SMD components and surface mount (SMT) technology for high circuit reliability;
No movable parts or flow-blocking parts inside the pipeline, resulting in almost no additional pressure loss during measurement;
The range can be modified online on site according to actual user needs;
The measurement result is unrelated to physical parameters such as flow distribution, fluid pressure, temperature, density, and viscosity;
High-definition backlit LCD display, full Chinese menu operation, convenient to use, simple to operate, easy to learn and understand;
Provides digital communication signal outputs such as RS485, RS232, Hart, and Modbus; (optional)
With self-check and self-diagnosis functions;
Hourly total recording function, recording total flow on an hourly basis, suitable for time-of-use metering systems (optional);
Internally equipped with three totalizers to separately display forward total, reverse total, and differential total, and internally equipped with a power-failure-proof clock that can record 16 power failure times. (optional);
Infrared handheld operator, 115KHZ communication rate, remotely operates all functions of the converter without contact over a long distance (optional).
Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Its main products include Swiss metallux ceramic piezoresistive sensors and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protection level transmitters, high-temperature guided-pressure level transmitters, rigid rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level meters
Notes 1. All supplied products are provided with a product certificate and instruction manual, including product number, technical parameters, wiring, ex-factory date, etc. Please check carefully to avoid misuse. 2. Wiring should be carried out strictly in accordance with our company's instructions for use. 3. This product is a precision instrument. Random disassembly, collision, dropping, and poking the sensor with sharp tools are prohibited. 4. The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes. 5. If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly. 6. During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse. 7. The quality warranty period is 12 months (damage caused by improper use such as pressure overload and wiring errors is not covered by the quality warranty). 8. Special products are customized products and do not participate in 7-day no-reason return. Customized products have a delivery lead time and are non-returnable and non-exchangeable.