Domestic capacitive pressure transmitter SDMB-3151/1151DF flange-mounted digital display transmitter intelligent differential pressure transmitter
Updated time:Feb 19, 2024
  • Domestic capacitive pressure transmitter SDMB-3151/1151DF flange-mounted digital display transmitter intelligent differential pressure transmitter
  • Domestic capacitive pressure transmitter SDMB-3151/1151DF flange-mounted digital display transmitter intelligent differential pressure transmitter
  • Domestic capacitive pressure transmitter SDMB-3151/1151DF flange-mounted digital display transmitter intelligent differential pressure transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us


      This intelligent single-flange level transmitter is a high-precision intelligent instrument product independently researched, developed, and produced by our company on the basis of many years of scientific research and practical experience.

      This single-flange level transmitter is a new generation of intelligent transmitter manufactured by adopting sensors produced with imported technology and integrating the advanced digital technology developed by our company. In principle, it adopts a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers an extremely high performance-to-price ratio, making it a mainstream product in the transmitter market.

      This single-flange level transmitter features a novel design principle, a complete range of models and specifications, convenient installation and use, and safety explosion-proof performance. It is especially well known for high accuracy, small size, light weight, convenient adjustment, good long-term stability, strong one-way overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a high reputation in both domestic and international markets. This series of 0.1-grade level transmitters can be widely used in electric power, metallurgy, petrochemical, pharmaceutical, instrument processing, and other industries.





Product Features


·Due to the use of a microprocessor, flexibility is increased and functions are enhanced;

·Has very strong self-diagnostic capability;

·Wide measuring range coverage 0~200m;

·Accuracy better than 0.1 grade, turndown ratio better than 40:1;

·Zero point and span adjustments do not affect each other;

·Both remote and local range and zero point adjustments are available;

·Two-wire system, compliant with HART? protocol


·Sensor has built-in non-volatile memory;

·Good stability, high accuracy, adjustable damping, and strong resistance to one-way overload;

·No mechanical transmission parts, low maintenance workload, sturdy and vibration-resistant;

·All universal parts, interchangeability between sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact with the medium, explosion-proof housing structure;

·Industry-proven superiority and reliability.


 


Performance Parameters


Technical Specifications   

      Application medium: liquid

      Measuring range:0-100m


      Output signal: linear output: 4~20mA output superimposed with HART? protocol digital signal (two-wire system)

      Power      supply: external 24V DC power supply (power supply range 14.5V~45V)

      Load characteristics: the maximum load resistance allowed in the load resistance loop is Rmax=(E-10.5)/0.0236(Ω), as shown below:

                     


      Installation in hazardous locations: flameproof type Exd Ⅱ CT6

                      intrinsically safe type Exia Ⅱ CT6

      Load characteristics: regardless of the output, after positive and negative migration, the upper and lower range limits shall not exceed the limits of the range. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL.

      Temperature range: medium temperature   -29~149℃ (silicone oil fill);

                                 -18~204℃ (inert liquid fill);15~315℃ (inert liquid fill);

                     Storage temperature           -40~100℃

                   Overall operating temperature  -40~85℃

                                           -20~70℃ (with digital display head);

      Relative humidity: 0~100%

      Static pressure and overpressure limits: 150lb flange: 41.37kPa (absolute pressure)~1.89MPa (at 37℃, silicone oil filled)

                             300lb flange: 41.37kPa (absolute pressure)~4.9MPa (at 37℃, silicone oil filled)

      Volume change: less than 0.16cm3

      Damping: time constant adjustable between 0.4~32.0s (silicone oil fill).

      Startup time: 3s, no preheating required.

Performance Indexes  

      (Under standard test conditions with no migration, 316 stainless steel isolation diaphragm, and other standard test conditions.)

      Turndown ratio: 40:1

      Accuracy: when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated span;

                    when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range;

      Stability: six-month error is ±0.15% of the maximum range;

      Temperature effect: zero error is ±0.375% of the maximum range/55℃.

       Including the total error of span and zero point, it is ±0.75% of the maximum range/55℃.

      Power supply effect: less than 0.005%/V of the output range


      Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum range.

      Load effect: as long as the voltage input to the transmitter is higher than 12V, there is no load effect within the load operating area.

      Installation position effect: when the pressure diaphragm is in the vertical position, a zero shift error of up to 0.25kPa may occur; when the pressure diaphragm is in the horizontal position, a zero shift of up to 0.98kPa may occur (for insertion-type flanges, the insertion length variation should be added), but it has no effect on the span, and this error can be corrected and eliminated. 

      Electromagnetic radiation: compliant with IEC801 standard 


 


Structural Materials

    Diaphragm in contact with the medium, including gasket and other contact surfaces: 316 stainless steel, Hastelloy C, tantalum;

    Insertion part: 316 stainless steel, Hastelloy C;

    Vent/drain valve: 316 stainless steel, Hastelloy C;

    Flange and connector: 316 stainless steel, Hastelloy C;

      “O” ring (in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;

    Mounting flange (non-contact) medium: cadmium-plated carbon steel (or 316 stainless steel);

    Bolt: carbon steel zinc-plated, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

    Fill liquid: silicone oil or inert liquid;

    Electrical housing: low-copper aluminum alloy;

    Coating: polyurethane epoxy resin.

    Pressure connection fitting:

                      High-pressure side: 3″ or 4″ 150lb flange or 300lb flange;

                      Low-pressure side: flange connection thread 1/4-18NPT (taper pipe thread);

    Connector connection thread 1/2-14NPT (taper pipe thread).  


 


Installation and Use


Before installing and using the single-flange level transmitter, carefully read the product catalog and instruction manual in detail. During installation, the flange must not leak, and the measuring range and wiring must be ensured to be correct. The housing of the level transmitter generally needs to be grounded, and the signal cable must not be laid together with the power cable. Strong electromagnetic interference should be avoided around the transmitter. During use, the transmitter should be periodically verified in accordance with industry regulations.


On-site fault inspection Most faults occurring at construction sites are caused by improper use and installation methods of the level transmitter. They can be summarized in several aspects. 1. Pipeline blockage or incorrect installation form, unreasonable pressure tapping point. 2. Leakage or blockage of the impulse pipe, residual gas in the liquid-filled pipe or residual liquid in the gas-filled pipe, and deposits in the process flange of the transmitter, forming a measurement dead zone. 3. Incorrect transmitter wiring, excessively high or low power supply voltage, and poor contact at the connection between the indicator head and the instrument wiring terminal. 4. Installation not carried out strictly according to technical requirements, and the installation method and on-site environment do not meet the technical requirements.


Any of the above faults in the level transmitter will cause abnormal transmitter output or inaccurate measurement. However, through careful inspection, strict use and installation in accordance with technical requirements, and timely effective measures, the problems can be eliminated. For faults that cannot be handled, the transmitter should be sent to the laboratory or manufacturer for further inspection.


Additional Device Installation


(1) In order to prevent the level transmitter from being affected by corrosion, excessive viscosity, or crystallization of the measured medium, an isolation device should be installed;


(2) In order to ensure that the level transmitter is not affected by sudden changes or pulsating pressure of the measured medium, a buffer should be installed. Especially during sharp pressure increases and decreases, it is most likely to damage and scrap the level transmitter, and even rupture the isolation diaphragm, causing leakage;


(3) In order to ensure that the level transmitter is not affected by the high temperature of the measured medium, a bent tube device filled with liquid should be installed;


(5) Dedicated level transmitters are strictly prohibited from other uses, and it is also strictly prohibited to perform measurement on devices without special reliable equipment, and it is even more strictly prohibited to use ordinary level transmitters for level measurement of special media;


(6) For newly purchased level transmitters, metrological verification must be carried out before installation and use, in order to prevent accuracy damage caused by vibration, damage, or other factors during transportation of the level instrument.


 


Routine Maintenance


1、Check dimensions. Only appropriate dimensions can avoid wear


2、Keep the flange clean


3、Select an appropriate location


4、Clean carefully


5、Keep dry


6、Avoid low-temperature interference


7、Prevent pressure overload


 


 


Solutions for Errors


1) The impulse pipe should be as short as possible;


2) When measuring liquid or steam, the impulse pipe should be connected upward to the process pipeline, and its slope should not be less than 1/12;


3) For gas measurement, the impulse pipe should be connected downward to the process pipeline, and its slope should not be less than 1/12;


4) The layout of the liquid impulse pipeline should avoid high points in the middle, and the layout of the gas impulse pipeline should avoid low points in the middle;


5) The same temperature should be maintained between the two impulse pipes;


6) In order to avoid friction effects, the diameter of the impulse pipe should be large enough;


7) There should be no gas in the liquid-filled impulse pipe;


8) When using isolation liquid, the liquid in the impulse pipes on both sides should be the same;


9) When using a cleaning agent, the connection point of the cleaning agent should be close to the pressure tapping port of the process pipeline, and the pipelines through which the cleaning agent passes should have the same length and diameter, and the cleaning agent should be prevented from passing through the transmitter.


 


Selection Steps


 


The selection of a single-flange level transmitter is very important. Below, based on my work experience, I will talk about the selection of a single-flange level transmitter.


1、The operating environment of the single-flange level transmitter.


2、Range. (For details, refer to level transmitter parameters - range)


3、Overload pressure. (Generally, differential pressure also requires the parameter of static pressure)


4、Accuracy.


5、Medium.


6、Supply voltage.


7、Output signal.


8、Shock and vibration.


9、Pressure response.


10、Flange size.


11、Electrical interface.


12、Safety certification.


13、Other additional functions


These are basically the main points. However, different transmitters may have different accessories, etc., so pay attention during selection.


 


After-Sales Service


I. Quality Assurance Service 


(I) Product quality is subject to the three guarantees 


  The product warranty period is one year from the date of delivery. During the warranty period, if there is a product quality problem caused by the product itself, our company provides free repair, replacement, and return services. 


   1、If general parts of the product fail and can be restored to use requirements after replacement, free scheduled repair shall be provided; 


   2、If major parts of the product fail and cannot be repaired on schedule, a qualified product of the same model and specification shall be replaced; 


 


(II) Scope of exemption 


  During the warranty period, product failures caused by the following human factors and force majeure are not covered by free repair, replacement, and return services:


   1、The application occasion is inconsistent with the parameters of the order contract;


   2、Product failure caused by improper use by the customer; 


   3、Customer's self-repair and modification of the product; 


   4、Serious external damage and deformation of the product, loss of product identification, and inability to identify the source of the product; 


   5、Product damage caused by natural disasters such as earthquakes, floods, fires; 


   6、Human factors. 


II. Lifetime Product Repair Service 


For faulty products beyond the warranty period and within the scope of exemption, our company will provide lifetime repair service for your products, and only charge the repair cost and product transportation cost. 




   

Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Main products include Swiss metallux ceramic piezoresistive sensors, self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protection level transmitters, high-temperature guided-pressure level transmitters, rigid rod level transmitters, flange level transmitters, wind pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level meters



Precautions 1.All supplied products are accompanied by product certificates and instruction manuals, including product number, technical parameters, wiring, factory date, etc. Please check carefully to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, collision, dropping, and poking the sensor with sharp tools are prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes.5.If any abnormality is found during use, the power should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months (damage caused by improper use such as pressure overload and wiring errors is not within the scope of the quality warranty).8.Special products are customized products, do not participate in the 7-day no-reason return policy, custom products have a lead time, no return and no exchange.

u=2776578472,2395865860&fm=199&app=68&f=JPEG.jpg

017b2b6174636fa2a680162ff2d3055.jpg

1fb685ae1bbc54f4b2c3b2f1778e130.jpg

Submit

Related Recommendations