Domestic capacitive pressure transmitter P400DP digital display transmitter intelligent differential pressure transmitter
Updated time:Feb 18, 2024
  • Domestic capacitive pressure transmitter P400DP digital display transmitter intelligent differential pressure transmitter
  • Domestic capacitive pressure transmitter P400DP digital display transmitter intelligent differential pressure transmitter
  • Domestic capacitive pressure transmitter P400DP digital display transmitter intelligent differential pressure transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The capacitive intelligent pressure/differential pressure/level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company based on many years of scientific research and practical experience.

The intelligent pressure/differential pressure/level transmitter is a new-generation intelligent transmitter produced by adopting a sensor core manufactured with ROSEMOUNT technology and combining it with advanced digital technology developed by our company. In principle, it uses a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers extremely high cost performance and has thus become a mainstream product in the transmitter market.

This intelligent pressure/differential pressure/level transmitter features a novel design principle, a complete range of models and specifications, convenient installation and use, and safety explosion-proof performance. It is especially renowned for high accuracy, compact size, light weight, easy adjustment, good long-term stability, strong one-way overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a high reputation in both domestic and international markets. This series of 0.1-grade capacitive intelligent transmitters includes multiple types such as pressure, differential pressure, absolute pressure, remote transmission, and level, and is equipped with corresponding optional products. It can be widely used in industries such as electric power, metallurgy, petrochemical, and instrument processing, and complies with the "IEC" standard requirements implemented in China.


                                                                     


Product Features


·The use of a microprocessor provides greater flexibility and enhanced functions;

·Strong self-diagnostic capability;

·Wide measuring range coverage from 0~0.2kPa…10MPa;

·Accuracy up to 0.1 grade, with a turndown ratio better than 40:1;

·Zero point and span adjustment do not affect each other;

·Both remote and local span and zero point are adjustable;

·Two-wire system, compliant with the HART protocol, capable of digital communication with ROSEMOUNT275 and MS-H376 handheld communicators without interrupting analog output;

·The sensor has built-in non-volatile memory;

·Good stability, high accuracy, adjustable damping, and strong resistance to one-way overload;

·No mechanical transmission parts, low maintenance workload, sturdy and vibration-resistant;

·All universal parts; interchange of the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact media, explosion-proof housing structure;

·Industry-proven superiority and reliability.


Performance Parameters


Technical Performance

Applicable media: liquid, gas, or steam

Measurement range: Range 3  0-0.2~6.0kPa

Range 4  0-6.0~40.0kPa

Range 5  0-40.0~200kPa

Range 6  0-0.16~1.0MPa

Range 7  0-0.4~2.0MPa

Range 8  0-1.6~10MPa

Output signal: linear output: 4~20mA output superimposed with HART protocol digital signal(two-wire system);

Square root output: when the input pressure is between 1.0%~100%, the output has a square root relationship with differential pressure; between 0%~0.1%, the output has a segmented linear relationship with differential pressure; there is no jump in the output between 4~20mADC, superimposed with HART? protocol digital signal(two-wire system), and users may choose linear output or square root output according to on-site conditions.

Power supply: externally supplied 24V DC,(power supply range 14.5V~45V)

Load characteristics: Maximum allowable load resistance in the load resistance loop Rmax=(E-10.5)/0.0236(Ω)


                 


Installation in hazardous locations: flameproof type Exd Ⅱ CT6;

                intrinsically safe type Exia Ⅱ CT6;

Load characteristics: After positive and negative migration, the upper and lower range limits shall not exceed the limits of the range. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL. Under square root output, positive and negative migration can be adjusted to 10% of the flow range.

Temperature range: medium temperature  -40~100℃

         storage temperature  -40~100℃

         operating temperature of the whole unit  -40~85℃

Relative humidity: 0~100%

Overpressure limit: applying 0(absolute pressure)~13.76MPa pressure to either side of the transmitter will not damage the transmitter; the flange can withstand 68.9MPa pressure; normal operating pressure should be from 3.45kPa(absolute pressure)to the upper range limit of the transmitter.

Volume change: less than 0.16cm3

Damping: time constant adjustable between 0.2~32.0s.

Start-up time: 3s, no preheating required.


Performance indicators:

    (Under standard test conditions with no migration, 316 stainless steel isolation diaphragm, and other standard conditions.)

    Turndown ratio: 40:1

    Accuracy: ranges 3, 4, 5

                when the turndown ratio is 1:1 to 10:1, it is ±0.1% of the calibrated span,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.05(1+0.1URL/span)% span,

                ranges 6, 7, 8

                      when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated span,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/span)% span,

    Stability: six-month error is ±0.15% of the maximum span;

    Temperature effect: ranges 4, 5, 6, 7, 8

                   zero error is ±0.25% of the maximum span/55℃.

         total error including span and zero point is ±0.5% of the maximum span/55℃.

    Note: for range 3, the temperature error should be doubled.

    Overpressure effect: after applying pressure of 140kgf/cm2, the error is ±0.25% of the maximum span range.

    Static pressure effect: under linear output, zero error: after applying static pressure of 140kgf/cm2, the zero error for ranges 4 and 5 is ±0.25% of the maximum span range, while the zero error for ranges 3, 6, 7, and 8 is ±0.5% of the maximum span range.

  Span error: the error for ranges 4, 5, 6, 7, and 8 is -1±0.25%/6.89MPa of the maximum span range, and the error for range 3 is -1.5±0.25%. This is a system error and can be eliminated by calibrating according to the actual static pressure before installation.

    Power supply effect: less than 0.005%/V of output span

    Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum span range.

    Load effect: as long as the voltage input to the transmitter is higher than 14.5V, there is no load effect within the load operating area.

    Installation position effect: may produce a zero position error not greater than 0.25 kPa, but it can be corrected and has no effect on the span;

Rotation of the measuring body relative to the flange has no effect.

    Electromagnetic radiation: complies with IEC801 standard


External Structure

 Structural materials:

        Isolation diaphragm and vent/drain valve: 316 stainless steel, Hastelloy C, Monel;

    Flange and joint: 316 stainless steel, Hastelloy C, Monel;

        “O” ring(in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;

    Fill fluid: silicone oil;

    Bolts: zinc-plated carbon steel, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

        Electrical housing: low-copper aluminum alloy;

        Coating: polyester epoxy resin;

        Pressure connection fitting: for ranges 3, 4, and 5, the center hole distance of the two-flange connection thread 1/4-18NPT is 54mm;

          Joint 1/2-14NPT or M20X1.5 male thread; with ball-cone sealing and joint, the center distance is 50.8, 54, 57.2mm;

        Weight: 3.5kg(excluding options)


                                                                                                       


Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has been mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Main products include Swiss metallux ceramic piezoresistive sensors, self-developed ceramic capacitive pressure sensors, diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning protection level transmitters, high-temperature guided pressure level transmitters, rigid rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouple/RTD temperature transmitters, and ultrasonic level gauges



Notes 1. All supplied products are provided with a product certificate and instruction manual, including product number, technical parameters, wiring, date of manufacture, etc. Please check carefully to avoid misuse. 2. Wiring should be carried out strictly in accordance with our company's instructions for use. 3. This product is a precision instrument. Random disassembly, collision, dropping, or poking the sensor with sharp tools is prohibited. 4. The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes. 5. If any abnormality is found during use, the power supply should be turned off, use should be stopped, inspection should be carried out, or our company's technical department should be contacted directly. 6. During transportation and storage, restore the original packaging and store in a cool, dry, and ventilated warehouse. 7. The quality warranty period is 12 months(damage caused by improper use such as pressure overload or wiring errors is not covered by the quality warranty). 8. Special products are customized products and do not participate in the 7-day no-reason return policy. Customized products have a lead time and are non-returnable and non-exchangeable.

u=2776578472,2395865860&fm=199&app=68&f=JPEG.jpg

017b2b6174636fa2a680162ff2d3055.jpg

1fb685ae1bbc54f4b2c3b2f1778e130.jpg

Submit

Related Recommendations