Domestic Capacitive Pressure Transmitter JS-3051 Absolute Pressure Sensor Differential Pressure Transmitter
Updated time:Feb 01, 2024
  • Domestic Capacitive Pressure Transmitter JS-3051 Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter JS-3051 Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter JS-3051 Absolute Pressure Sensor Differential Pressure Transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The capacitive intelligent pressure/differential pressure/level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company based on many years of scientific research and practical experience.

The intelligent pressure/differential pressure/level transmitter is a new-generation intelligent transmitter manufactured using a sensor core produced with ROSEMOUNT technology, combined with advanced digital technology developed by our company. In principle, it adopts a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers extremely high cost performance, making it a mainstream product in the transmitter market.

This intelligent pressure/differential pressure/level transmitter features a novel design principle, complete varieties and specifications, easy installation and use, and safety explosion-proof performance. It is especially renowned for high accuracy, small size, light weight, convenient adjustment, good long-term stability, strong one-way overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a high reputation in domestic and international markets. This series of 0.1 grade capacitive intelligent transmitters includes pressure, differential pressure, absolute pressure, remote transmission, level, and many other types, and is equipped with corresponding optional products. It can be widely used in electric power, metallurgy, petrochemical, instrument processing, and other industries, and complies with the "IEC" standard requirements promoted in China.


                                                                     


Product Features


·The use of a microprocessor increases flexibility and enhances functions;

·It has very strong self-diagnosis capability;

·Wide range coverage 0~0.2kPa…10MPa;

·Accuracy up to 0.1 grade, turndown ratio better than 40:1;

·Zero point and span adjustments do not affect each other;

·Both remote and local span and zero point are adjustable;

·Two-wire system, compliant with HART protocol, capable of digital communication with ROSEMOUNT275 and MS-H376 handheld communicators without interrupting analog output;

·The sensor has built-in non-volatile memory;

·Good stability, high accuracy, adjustable damping, and strong resistance to one-way overload;

·No mechanical transmission parts, low maintenance workload, sturdy and vibration-resistant;

·All universal parts; interchangeability between the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact with the measured medium, explosion-proof housing structure;

·Industry-proven superiority and reliability.


Performance Parameters


Technical Performance

Applicable media: liquid, gas, or vapor

Measurement range: Range 3  0-0.2~6.0kPa

Range 4  0-6.0~40.0kPa

Range 5  0-40.0~200kPa

Range 6  0-0.16~1.0MPa

Range 7  0-0.4~2.0MPa

Range 8  0-1.6~10MPa

Output signal: linear output: 4~20mA output superimposed with HART protocol digital signal(two-wire system);

Square root output: within 1.0%~100% input pressure, the output has a square root relationship with differential pressure; within 0%~0.1%, the output has a segmented linear relationship with differential pressure; there is no jump change within 4~20mADC output, superimposed with HART? protocol digital signal(two-wire system), and users can choose linear output or square root output according to on-site conditions.

Power      supply: externally supplied 24V DC, (power supply range 14.5V~45V)

Load characteristics: the maximum allowable load resistance in the load resistor circuit is Rmax=(E-10.5)/0.0236(Ω)


                 


Installation in hazardous locations: flameproof type Exd Ⅱ CT6;

               intrinsically safe type Exia Ⅱ CT6;

Load characteristics: after positive and negative migration, the upper and lower limits of the range must not exceed the limits of the range. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL. During square root output, positive and negative migration can be adjusted and calibrated to 10% of the flow range.

Temperature range: medium temperature  -40~100℃

         storage temperature  -40~100℃

         overall operating temperature  -40~85℃

Relative humidity: 0~100%

Overpressure limit: applying 0(absolute pressure)~13.76MPa pressure to either side of the transmitter will not damage the transmitter; the flange can withstand 68.9MPa pressure; normal operating pressure should be from 3.45kPa(absolute pressure)to the upper limit of the transmitter range.

Volume change: less than 0.16cm3

Damping: the time constant is adjustable between 0.2~32.0s.

Start-up time: 3s, no preheating required.


Performance indicators:

   (Under standard test conditions without migration, with 316 stainless steel isolation diaphragm and other standard test conditions.)

    Range ratio: 40:1

    Accuracy: ranges 3, 4, 5

                  when the range ratio is 1:1 to 10:1, it is ±0.1% of the calibrated range,

                      when the range ratio is 10:1 to 40:1, it is ±0.05(1+0.1URL/range)% range,

                ranges 6, 7, 8

                      when the range ratio is 1:1 to 10:1, it is ±0.15% of the calibrated range,

                      when the range ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range,

    Stability: six-month error is ±0.15% of the maximum range;

    Temperature effect: ranges 4, 5, 6, 7, 8

                   zero point error is ±0.25%/55℃ of the maximum range.

        total error including range and zero point is ±0.5%/55℃ of the maximum range.

    Note: for range 3, the temperature error should be doubled.

    Overpressure effect: after applying 140kgf/cm2 pressure, the error is ±0.25% of the maximum range.

    Static pressure effect: during linear output, zero point error: after applying static pressure of 140kgf/cm2, the zero point error for ranges 4 and 5 is ±0.25% of the maximum range, and the zero point error for ranges 3, 6, 7, and 8 is ±0.5% of the maximum range.

  Range error: the error for ranges 4, 5, 6, 7, and 8 is -1±0.25%/6.89MPa of the maximum range, and the error for range 3 is -1.5±0.25%. This is a system error and can be eliminated by calibration according to the actual static pressure before installation.

    Power supply effect: less than 0.005%/V of output range

    Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum range.

    Load effect: as long as the input voltage to the transmitter is higher than 14.5V, there is no load effect within the load operating area.

    Installation position effect: the maximum zero position error produced is no greater than 0.25 kPa, but it can be corrected and has no effect on the range;

Rotation of the measuring body relative to the flange has no effect.

    Electromagnetic radiation: compliant with IEC801 standard


Appearance and Structure

 Structural materials:

        Isolation diaphragm and vent/drain valve: 316 stainless steel, Hastelloy C, Monel;

    Flange and joints: 316 stainless steel, Hastelloy C, Monel;

        “O” ring(in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;

    Filling liquid: silicone oil;

    Bolts: zinc-plated carbon steel, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

        Electrical housing: low-copper aluminum alloy;

        Coating: polyurethane epoxy resin;

        Pressure connection fittings: for ranges 3, 4, and 5, the center hole distance of the two-flange connection thread 1/4-18NPT is 54mm;

         joint 1/2-14NPT or M20X1.5 male thread; when using cone seal with joint, the center distance is 50.8, 54, 57.2mm;

        Weight:   3.5kg(excluding options)


                                                                                                       


Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Its main products include Swiss metallux ceramic piezoresistive sensors and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protected level transmitters, high-temperature guided-pressure level transmitters, straight-rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouple/RTD temperature transmitters, ultrasonic level gauges



Notes 1.All supplied products are provided with product certificates and instruction manuals, including product numbers, technical parameters, wiring, factory date, etc. Please carefully check them to avoid incorrect use.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, collision, dropping, or probing the sensor with sharp tools is prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months(damage caused by improper use such as pressure overload and incorrect wiring is not covered by the quality warranty).8.Special products are customized products and do not participate in the 7-day no-reason return policy. Customized products have a delivery period and are non-returnable and non-exchangeable.