Domestic Capacitive Pressure Transmitter CS1151DP Absolute Pressure Sensor Differential Pressure Transmitter
Updated time:Feb 18, 2024
  • Domestic Capacitive Pressure Transmitter CS1151DP Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter CS1151DP Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter CS1151DP Absolute Pressure Sensor Differential Pressure Transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The capacitive intelligent pressure/differential pressure/level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company on the basis of many years of scientific research and practical experience.

The intelligent pressure/differential pressure/level transmitter is a new-generation intelligent transmitter produced using a sensor core manufactured with ROSEMOUNT technology, combined with advanced digital technology developed by our company. In principle, it adopts a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers an excellent performance-to-price ratio and has therefore become a mainstream product in the transmitter market.

This intelligent pressure/differential pressure/level transmitter features a novel design principle, complete varieties and specifications, convenient installation and use, and safety explosion-proof characteristics. It is especially well known for high accuracy, compact size, light weight, convenient adjustment, good long-term stability, strong unidirectional overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a very high reputation in domestic and international markets. This series of 0.1 grade capacitive intelligent transmitters includes pressure, differential pressure, absolute pressure, remote transmission, level, and other types, and is equipped with corresponding optional products. It can be widely used in electric power, metallurgy, petrochemical, instrument processing, and other industries, and complies with the "IEC" standard requirements implemented in China.


                                                                     


Product Features


·The use of a microprocessor provides greater flexibility and enhanced functions;

·Strong self-diagnostic capability;

·Wide measuring range coverage 0~0.2kPa…10MPa;

·Accuracy reaches 0.1 grade, with a turndown ratio better than 40:1;

·Zero point and span adjustment do not affect each other;

·Both remote and local range and zero point are adjustable;

·Two-wire system, compliant with HART protocol, capable of digital communication with ROSEMOUNT275 and MS-H376 handheld communicators without interrupting analog output;

·The sensor is equipped with non-volatile memory;

·Good stability, high accuracy, adjustable damping, and strong resistance to unidirectional overload;

·No mechanical transmission parts, low maintenance workload, sturdy and vibration-resistant;

·All universal parts, and interchangeability between the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact media, explosion-proof housing structure;

·Industry-proven superiority and reliability.


Performance Parameters


Technical Performance

Applicable media: liquid, gas, or steam

Measuring range: Range 3  0-0.2~6.0kPa

Range 4  0-6.0~40.0kPa

Range 5  0-40.0~200kPa

Range 6  0-0.16~1.0MPa

Range 7  0-0.4~2.0MPa

Range 8  0-1.6~10MPa

Output signal: linear output: 4~20mA output superimposed with HART protocol digital signal(two-wire system);

Square root output: between 1.0%~100% input pressure, the output has a square root relationship with differential pressure; between 0%~0.1%, the output has a segmented linear relationship with differential pressure; there is no sudden jump between 4~20mADC output, superimposed with HART? protocol digital signal(two-wire system), and users can choose linear output or square root output according to on-site conditions.

Power      supply: externally supplied 24V DC, (power supply range 14.5V~45V)

Load characteristic: maximum allowable load resistance in the load resistor circuit Rmax=(E-10.5)/0.0236(Ω)


                 


Installation in hazardous locations: flameproof type Exd Ⅱ CT6;

                intrinsically safe type Exia Ⅱ CT6;

Load characteristic: after positive or negative migration, the upper and lower range limits shall not exceed the range limits. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL. During square root output, the positive and negative migration can be adjusted and calibrated to 10% of the flow range.

Temperature range: medium temperature      -40~100℃

         storage temperature      -40~100℃

         complete unit operating temperature   -40~85℃

Relative humidity: 0~100%

Overpressure limit: applying 0(absolute pressure)~13.76MPa pressure to either side of the transmitter will not damage the transmitter; the flange can withstand 68.9MPa pressure; normal operating pressure should be from 3.45kPa(absolute pressure)to the upper limit of the transmitter range.

Volume change: less than 0.16cm3

Damping: adjustable time constant between 0.2~32.0s.

Startup time: 3s, no preheating required.


Performance indicators:

    (Under standard test conditions with no migration, 316 stainless steel isolation diaphragm, and other standard conditions.)

    Turndown ratio: 40:1

    Accuracy: ranges 3, 4, 5

                 when the turndown ratio is 1:1 to 10:1, it is ±0.1% of the calibrated range,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.05(1+0.1URL/range)% range,

                ranges 6, 7, 8

                      when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated range,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range,

    Stability: six-month error is ±0.15% of the maximum range;

    Temperature effect: ranges 4, 5, 6, 7, 8

                    zero error is ±0.25% of the maximum range/55℃.

         total error including range and zero point is ±0.5% of the maximum range/55℃.

    Note: for range 3, the temperature error should be doubled.

    Overpressure effect: after applying pressure of 140kgf/cm2, the error is ±0.25% of the maximum range.

    Static pressure effect: under linear output, zero error: after applying static pressure of 140kgf/cm2, the zero error of ranges 4 and 5 is ±0.25% of the maximum range, and the zero error of ranges 3, 6, 7, and 8 is ±0.5% of the maximum range.

  Range error: the error of ranges 4, 5, 6, 7, and 8 is -1±0.25%/6.89MPa of the maximum range, and the error of range 3 is -1.5±0.25%. This is a system error and can be eliminated by calibrating according to the actual static pressure before installation.

    Power supply effect: less than 0.005%/V of output range

    Vibration effect: on any axis, at a frequency of 200Hz, the resulting error is ±0.05%/g of the maximum range.

    Load effect: as long as the input voltage to the transmitter is higher than 14.5V, there is no load effect within the load operating area.

    Installation position effect: may produce a zero shift error no greater than 0.25 kPa, but it can be corrected, with no effect on the range;

Rotation of the measuring body relative to the flange has no effect.

    Electromagnetic radiation: complies with IEC801 standard


Appearance Structure

 Structural materials:

        Isolation diaphragm and vent/drain valve: 316 stainless steel, Hastelloy C, Monel;

    Flange and connector: 316 stainless steel, Hastelloy C, Monel;

        “O” ring(in contact with measuring medium): fluororubber, nitrile rubber, ethylene-propylene;

    Filling liquid: silicone oil;

    Bolts: carbon steel galvanized, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

        Electrical housing: low-copper aluminum alloy;

        Coating: polyurethane epoxy resin;

        Pressure connection: for ranges 3, 4, and 5, the center hole distance of the threaded holes for the two-flange connection is 54mm;

         Connector 1/2-14NPT or M20X1.5 male thread; when using a ball-cone sealing with connector, the center distances are 50.8, 54, 57.2mm;

        Weight:   3.5kg(excluding options)


                                                                                                       


Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has been mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Its main products include Swiss metallux ceramic piezoresistive sensors and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning protection level transmitters, high-temperature guided pressure level transmitters, rigid rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouple/RTD temperature transmitters, ultrasonic level meters



Notes 1.All supplied products are provided with a product certificate and instruction manual, including product number, technical parameters, wiring, factory date, etc. Please carefully check them to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Arbitrary disassembly, collision, dropping, or poking the sensor with sharp tools is prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after 30 minutes of preheating.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months(damage caused by improper use such as pressure overload or incorrect wiring is not covered by the quality warranty).8.Special products are customized products, do not participate in 7-day no-reason return, customized products have a delivery lead time, and are non-returnable and non-exchangeable.

u=2776578472,2395865860&fm=199&app=68&f=JPEG.jpg

017b2b6174636fa2a680162ff2d3055.jpg

1fb685ae1bbc54f4b2c3b2f1778e130.jpg

Submit

Related Recommendations