Application Case Sharing of the RSL15 Coin-Type Sensor in Medical Devices
Added to Favorites:125

In the precision measurement field of medical devices, the RSL15 coin-type sensor, with its miniaturized design and compact size advantages, provides high-precision force monitoring solutions for key equipment such as infusion pumps and ventilators. This article will share innovative application cases of this sensor in medical scenarios, helping technical evaluators understand its performance characteristics and selection value.


I. Sensor Requirements Under the Trend of Medical Device Miniaturization


As medical devices develop toward portable and wearable directions, traditional sensors are difficult to meet the needs of new devices due to their excessive size. The RSL15 coin-type sensor features a miniature structure with a diameter of only 15mm and a thickness of 6.5mm, making it perfectly suitable for space-constrained scenarios such as infusion pump pressure monitoring modules and ventilator airflow control units. Its 316L stainless steel material has passed ISO 13485 medical device quality management system certification, demonstrating outstanding biocompatibility and corrosion resistance, and is particularly suitable for ICU equipment environments with long-term contact with medical fluids.


II. Comparison of Core Performance Parameters and Industry Standards


ParameterRSL15Industry Average
Measuring Range0-50N0-30N
Non-linearity≤±0.3%FS≤±0.5%FS
Operating Temperature-20℃~80℃0℃~70℃

This sensor uses MEMS technology to achieve a resolution of 0.1mN, enabling accurate identification of 0.5% flow fluctuations in neonatal ventilator pressure monitoring. Compared with similar RSW series products, its IP68 protection rating is more suitable for medical scenarios requiring frequent disinfection, and it has passed electromagnetic compatibility testing for FDA 510(k) premarket notification.


III. Analysis of Typical Medical Application Scenarios


In smart infusion pump projects, the RSL15 is integrated into the peristaltic pump head pressure monitoring module to detect pipeline blockage conditions in real time. When the pressure value exceeds the preset threshold, the system can trigger an alarm and suspend infusion within 50ms. Its compact size allows 3 sensors to be arranged within a single pump head to form a redundant detection network, reducing the false alarm rate caused by failures by 72% compared with traditional solutions. Another innovative case is its use in the weighing module of portable dialysis machines, where a circular array composed of 6 RSL15 sensors can achieve liquid metering accuracy of ±2g, meeting the requirements of the EN 60601-1-11 standard for home-use medical equipment.


IV. Guide to Key Dimensions for Technical Evaluation


  • Environmental adaptability: It is necessary to verify the sealing performance after 1000 wipes with 75% alcohol
  • Signal stability: It is recommended to conduct a continuous 72-hour drift test, with a requirement of ≤±0.05%FS/8h
  • Dynamic response: For ventilator applications, the step response time should be <10ms
  • Installation compatibility: Two mounting solutions are provided: M3×0.5 threaded mounting and epoxy resin bonding

V. Why Choose Shenghongchuang Sensors


As a national high-tech enterprise, Xi'an Shenghongchuang Instrumentation Co., Ltd. has 10 years of experience in the R&D of medical-grade sensors. Our production base in Xixian New Area is equipped with a Class 10000 cleanroom, and all RSL15 series products have passed 5 million-cycle fatigue life testing conducted by third-party institutions. In response to the special needs of medical device manufacturers, we provide:

  1. Free sample testing and customized calibration services
  2. A complete set of technical documentation compliant with ISO 14971 risk management requirements
  3. 24-hour-response fault diagnosis support for clinical environments

Contact our medical industry technical consultants now to obtain the performance verification report and OEM cooperation solution for the RSL15 in your specific application.