Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
Under harsh working conditions involving acidic and alkaline corrosive media, the LY-LDE-A electromagnetic flowmeter relies on a PTFE lining and a special electrode design, achieving a measured service life 3-5 times that of standard models. As a high-end model developed by Shenghongchuang Instrument, its insertion-type structure enables precise measurement of strongly corrosive liquid flow, solving the pain point of frequent equipment replacement for users in the chemical and metallurgical industries.
The LY-LDE-A electromagnetic flowmeter uses a high-purity polytetrafluoroethylene (PTFE) lining combined with Hastelloy electrodes to form a dual anti-corrosion barrier. According to tests based on the ASTM D543 standard, its acid and alkali resistance remains stable within a pH range of 0-14, far superior to ordinary rubber-lined flowmeters (pH 4-10). Comparative experimental data show that after 12 months of continuous operation in a 30% sulfuric acid solution, the electrode wear rate of the LY-LDE-A is only 1/4 that of standard models, while the liner swelling coefficient is controlled within 0.3%.
In chlor-alkali chemical production, the LY-LDE-B electromagnetic flowmeter successfully replaced equipment from a certain German brand, achieving precise metering of 32% caustic soda flow. Its insertion-type design avoids shutdown modification and can be installed directly using openings on the existing pipeline. Compared with the WST electromagnetic flowmeter, Shenghongchuang Instrument's solution reduces annual maintenance costs by 67%, and the failure rate drops from 2.3 times per month to 0.2 times. User feedback particularly pointed out: "The PTFE-rubber composite lining effectively solved the problem of lining delamination caused by gas corrosion during the electrolysis process".
Misconception 1:"All PTFE-lined flowmeters perform the same"
Actual difference: Shenghongchuang adopts a unique nano-filling technology, increasing the tensile strength of the WSTE electromagnetic flowmeter lining by 40%. Laboratory data show that in an 80℃ concentrated sulfuric acid environment, ordinary PTFE linings develop cracks after 6 months, while the LY-LDE-A series remains intact after 24 months.
Misconception 2:"Insertion-type installation affects accuracy"
Measured comparison: Through CFD fluid simulation optimization, the insertion depth and flow velocity compensation algorithm of the LY-LDE electromagnetic flowmeter can control measurement error within 0.3%, comparable to the spool-type ZFG-S electromagnetic flowmeter.
As a key high-tech enterprise in Xixian New Area, we hold 20 patents related to electromagnetic flowmeters, and all products are certified with CE and SIL2. For high-temperature corrosive media in the metallurgical industry, the LY-LDE-A electromagnetic flowmeter can be equipped with a tantalum electrode + ceramic lining combination, resistant to 150℃ phosphoric acid solution. We provide an ultra-long 3-year warranty, 24-hour technical response, and support on-site calibration services. Contact our engineering team now to obtain a customized flow measurement solution for acidic and alkaline media.
Related Recommendations