News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

What material should be used for sodium hypochlorite level sensors?
Added to Favorites:125

For sodium hypochlorite level measurement, first consider the corrosive properties of the medium

Why ordinary level sensors are prone to failure

Sodium hypochlorite solution has strong oxidizing properties and is commonly used in tap water disinfection, wastewater treatment, food cleaning, swimming pool chemical dosing, and chemical processes. Its available chlorine concentration, solution temperature, and tank ventilation conditions all affect the rate of corrosion. In particular, conventional industrial chemical solutions with concentrations of 5% to 12% can easily cause pitting corrosion, crevice corrosion, and stress corrosion when in long-term contact with metal wetted components.

For level sensors, it is not enough to consider whether the probe housing is corrosion-resistant. The materials of the diaphragm, sealing rings, pressure ports, cable sheath, and installation fittings must also be confirmed. In actual applications, some sensors use stainless steel for the main body but have unsuitable sealing materials around the diaphragm. Once the chemical solution penetrates through gaps, it can cause zero drift, unstable output, or even moisture damage to internal circuits.

Sodium hypochlorite gradually decomposes under high temperatures, light exposure, and long-term storage conditions, and may release corrosive gases. Therefore, non-contact level instruments installed at the tank top must not overlook vapor-phase corrosion. During technical evaluation, “liquid-phase contact” and “vapor-phase exposure” should be assessed separately rather than selecting materials solely based on the corrosion grade of the liquid itself.

On-Site FactorsImpact on SensorsSelection Considerations
Available Chlorine ConcentrationAs concentration increases, the risk of aging and corrosion of wetted materials increases.Specify the commonly used concentration, maximum concentration and replenishment frequency.
Medium TemperatureAs temperature rises, the rate of chemical reactions generally increases accordingly.Confirm the long-term operating temperature and the maximum short-term temperature.
Tank VaporMay corrode the instrument housing, wiring terminals and cable connectors.Pay attention to vapor-phase corrosion protection and junction box sealing.
Crystallization and DepositsMay clog pressure ports or affect hydrostatic measurement response.Give priority to flush diaphragm structures or non-contact measurement methods.

How to compare commonly used wetted materials

Application limits of PTFE, PVDF, and 316L

For level sensors in direct contact with sodium hypochlorite, PTFE is usually the preferred corrosion-resistant material. It offers good resistance to most strongly oxidizing media and high chemical stability, making it suitable for diaphragms, seals, linings, and probe protective components. However, PTFE has relatively limited mechanical strength. For high-pressure conditions, frequent vibration, or complex assembly structures, the support method and sealing design must be evaluated comprehensively.

PVDF combines corrosion resistance with mechanical strength and is also commonly used for level measurement in sodium hypochlorite storage tanks, dosing tanks, and pipelines. It is more resistant to chemical media than some common plastics and is suitable for submersible probe housings, flange linings, and pressure-guiding structures. Where site temperature is stable, concentration is defined, and pressure is low, PVDF solutions generally offer good practicality and cost-effectiveness.

316L stainless steel is widely used in ordinary water media, but it should not simply be regarded as a universal corrosion-resistant choice for sodium hypochlorite environments. Chlorine-containing oxidizing media can adversely affect stainless steel, particularly under high concentrations, elevated temperatures, retained liquid accumulation, or insufficient weld treatment, where the risk increases significantly. If the instrument includes 316L components, they should be prevented from directly contacting the liquid or protected by reliable isolation layers such as PTFE or PVDF.

MaterialSuitability for Sodium HypochloriteTypical Application LocationSelection Notes
PTFEExcellentDiaphragms, seals and liningsPay attention to structural support and installation stress.
PVDFGoodProbe housings, flange linings and pipe fittingsVerify the temperature, pressure and concentration ranges.
CeramicDepends on the specific formulation.Flush diaphragm pressure sensing elementsConfirm the diaphragm and seal combination as a priority.
316L Stainless SteelNot suitable for long-term direct contact with the liquid.Non-wetted structural components and external mounting partsAvoid use in direct-contact applications with high chlorine concentrations and high temperatures.

Select the level sensor type according to tank structure

Contact and non-contact types each have applicable operating conditions

For open or atmospheric sodium hypochlorite storage tanks, if the tank depth is relatively fixed and there is little foam, a corrosion-resistant submersible hydrostatic level sensor can be used. Its advantages include stable output and direct installation. Its commonly used 4-20mA signal can be connected to PLC, DCS, or intelligent digital display control instruments. The wetted probe should preferably use a PVDF housing with a PTFE sealing structure, and the cable sheath should also be corrosion-resistant.

For closed tanks, chemical tanks with high volatility, or applications where the sensor should not contact the medium, non-contact solutions such as radar level meters and ultrasonic level meters can be evaluated. Radar measurement is relatively less affected by vapor and pressure changes, making it suitable for enclosed storage tanks with high stability requirements. Ultrasonic solutions have lower costs, but the effects of foam, condensation, moisture, and internal tank obstructions on echo signals must be considered.

If the level is used only for high- and low-level alarms or dosing pump interlocks, a continuous level transmitter may not be necessary. Corrosion-resistant float level switches, capacitive level switches, or externally mounted level switches can be used in such applications. Key selection factors include switch contact capacity, installation position, risk of false operation, and compatibility with the control cabinet's 24VDC power supply system.

Measuring range and accuracy must be considered in relation to installation height

The measuring range of a hydrostatic level sensor should be close to the actual liquid column height while allowing an appropriate margin. For example, when the actual liquid level height is 3 meters, a 0-5 meter water column range can be selected to avoid long-term full-scale operation. The range should also not be expanded to 0-20 meters water column, otherwise the effective resolution will decrease and low-level changes will be difficult to identify.

For continuous measurement in conventional chemical storage tanks, an accuracy of 0.5%FS can generally meet control requirements. For chemical preparation metering, inventory accounting, or proportional dosing control, the 0.25%FS grade can be further considered. Accuracy parameters should also be understood in conjunction with temperature drift, long-term stability, and installation errors. Factory accuracy alone does not represent the final on-site performance.

Sediment at the tank bottom, agitated liquid flow, and dosing impact can cause force fluctuations on hydrostatic probes. The probe should not be placed directly against the tank bottom or directly opposite the liquid inlet. An installation distance of 100 to 300 mm from the tank bottom can generally be maintained, and a guide tube or protective cover can be used to reduce direct liquid impact. This both reduces signal fluctuations and facilitates subsequent maintenance and cleaning.

After selecting the right corrosion-resistant materials, installation and maintenance must also be properly implemented

A complete sealing design determines long-term reliability

Failure points of sodium hypochlorite level sensors often occur at cable entries, fitting threads, and sealing rings. When purchasing, the list of wetted parts should be clearly specified; it is not sufficient merely to confirm that the “probe is corrosion-resistant.” For instruments installed at the tank top, it is recommended to check the protection rating of the junction box. IP65 or higher is commonly selected for typical sites, while cable fitting sealing should be enhanced in humid areas or areas subject to frequent washdown.

After a submersible sensor is installed, the empty-tank zero point, full-tank displayed value, and actual liquid level height should be recorded during initial commissioning as a reference for future inspections. If the signal fluctuates over a long period, the zero point gradually shifts, or the difference between the displayed value and a manual level gauge continues to increase, check for deposits on the probe surface, blockage of pressure ports, cable damage, and seal aging rather than repeatedly adjusting parameters only in the control system.

It is recommended to establish a maintenance cycle based on chemical consumption and on-site operating intensity. Under general operating conditions, appearance, wiring, and output signals can be checked every 3 to 6 months. The inspection cycle should be shortened for high-temperature, high-concentration, or continuous dosing applications. When replacing seals, ensure that the new material is compatible with sodium hypochlorite and avoid mixing different materials, which may create new weak points.

Selection data should be confirmed clearly at one time

When submitting selection requirements, provide the sodium hypochlorite concentration, medium temperature, tank height, whether the tank is closed, whether agitation and foam are present, installation method, power supply voltage, and control system interface. For projects with an existing PLC system, also specify whether 4-20mA, RS485, or relay output is required to determine the matching level sensor and supporting instruments.

Where functions such as high- and low-level interlocks, pump start/stop control, and chemical remaining-level alarms are required, it is recommended to review the control logic at the same time. Continuous level transmitters are responsible for trend monitoring and analog control, while level switches provide independent alarms or protective interlocks. Their combined use can improve system redundancy and reduce downtime risks caused by abnormalities in a single measuring element.

For sodium hypochlorite level measurement, first confirm corrosion-resistant wetted materials such as PTFE or PVDF, then select hydrostatic, radar, ultrasonic, or level switch solutions according to the tank structure. Site medium parameters, tank drawings, and control requirements can be reviewed by professional technical personnel. Purchase and installation should be carried out after targeted confirmation of wetted materials, measuring range, signal output, and installation structure.

Submit