What should be done if the accuracy of the YSJ-B1 pressure transmitter shows deviation? This article provides a detailed analysis of the calibration method for diffused silicon liquid and gas pressure sensors through actual cases. As a professional instrumentation manufacturer, we will share how to quickly diagnose and solve the accuracy issues of the YSJ-B1 pressure transmitter, helping operators improve equipment efficiency.
Diffused silicon pressure sensors use the semiconductor piezoresistive effect principle, converting pressure signals into electrical signal output through the Wheatstone bridge on the silicon chip. As a typical representative, the YSJ-B1 pressure transmitter may have accuracy deviations originating from: 1) zero drift caused by temperature changes; 2) sensor aging after long-term use; 3) the influence of on-site installation stress; 4) changes in medium characteristics. According to the requirements of the GB/T 15478-2015 standard, the accuracy grade of diffused silicon liquid and gas pressure sensors must be ensured through periodic calibration.
In the chlorine gas transmission pipeline of a chemical plant, the YSJ-B1 pressure transmitter showed a measurement error of ±1.2%FS for 3 consecutive months. Our technical team resolved the problem through the following steps: first, using the domestic differential pressure transmitter ZEN302 diffused silicon integrated differential pressure transmitter as the reference equipment for comparative testing, it was confirmed that the original transmitter had zero drift. Then, according to the JJG 882-2019 regulation, a three-point calibration was carried out using a standard pressure source (0%、50%、100% range), and it was specifically found that when the medium temperature exceeded 70℃, the temperature compensation coefficient needed to be adjusted. Finally, through recalibration, the accuracy was restored to Class 0.25.
For PM-PM320, YSJ-B1 and other series products, the standard calibration procedure should include:
It is recommended to carry out preventive calibration once every 6 months, and for high-frequency equipment such as CX-203, it should be shortened to 3 months.
As a national high-tech enterprise, Xi'an Shenghongchuang Instrument Co., Ltd. has the following core advantages: 1) all S-10 pressure transmitters are tested by an ISO/IEC 17025 certified laboratory before leaving the factory; 2) we provide full-range replacement solutions including the ZEN302 series; 3) the technical support team has more than 10 years of service experience in the petrochemical and power industries. If you need to obtain the complete calibration manual for the YSJ-B1 pressure transmitter, please contact our engineering service center.