News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

RH-TUF-2000S Ultrasonic Flow Sensor:An Energy-Saving Tool for Municipal Water Supply Systems
Added to Favorites:125

A New Energy-Saving Choice for Municipal Water Supply Systems:RH-TUF-2000S Ultrasonic Flow Sensor


In municipal water supply systems,the RH-TUF-2000S ultrasonic flow sensor has become an ideal choice for flow control with its high-precision measurement and energy-saving features。This wall-mounted ultrasonic transmitter professionally developed by Xi'an Shenghongchuang Instrument Co., Ltd. can not only effectively reduce energy consumption,but also offers the advantages of convenient installation and simple maintenance,providing business evaluators with a cost-effective solution。


1. Breakthrough in High-Precision Measurement Technology


RH-TUF-2000S adopts the advanced ultrasonic transit-time measurement principle,with measurement accuracy up to ±1%,far higher than that of traditional mechanical flowmeters。This technology calculates flow velocity through the time difference of ultrasonic wave propagation in the fluid,with no mechanical moving parts at all,avoiding wear and pressure loss。This non-contact measurement method is especially suitable for municipal water supply systems,accurately monitoring flow changes in the pipeline network and providing reliable data support for water resource management。


Compared with products in the same series such as ZFD-100FB and HZ-100A,RH-TUF-2000S has optimized and upgraded its signal processing algorithm,adopting digital signal processing(DSP)technology to effectively suppress measurement interference caused by pipeline vibration and fluid turbulence。Its wide turndown ratio reaches 1000:1,meeting full-range accurate measurement requirements from tiny flow rates to large flow rates。


2. Analysis of Significant Energy-Saving Benefits


As an energy-saving tool in municipal water supply systems,the direct energy-saving effect of RH-TUF-2000S is mainly reflected in two aspects:First,the device itself produces almost no pressure loss,reducing pumping energy consumption by about 3-8% compared with traditional flowmeters;Second,through accurate flow monitoring,pipeline network operating parameters can be optimized,achieving overall system energy savings of 5-15%。


Practical application cases show that in a DN200 diameter water supply pipeline,a comparative test between BST-100A and RH-TUF-2000S shows that the latter can save about 4500kWh of electricity annually。If promoted across the entire water supply network,the energy-saving benefits will be highly considerable。When calculating the return on investment,business evaluators should take this long-term energy-saving benefit into account。


3. Convenient Installation and Intelligent Maintenance


RH-TUF-2000S adopts a wall-mounted design,requiring no pipe cutting or water supply shutdown during installation,and installation can be completed through external clamp-on mounting。This non-invasive installation method greatly reduces project difficulty and cost,making it especially suitable for renovation projects of existing pipeline networks。The product provides multiple installation options,including TOP-UFB standard clamp installation and TOP-UFH86 dedicated bracket installation,adapting to different pipe diameters and site conditions。


Intelligent maintenance functionality is another major highlight of this product。The device has a built-in self-diagnostic system,which can monitor sensor status in real time and output diagnostic information through HART or MODBUS protocols。The data logging function of the LT-GDUF2000 series can store operating data for up to 1 year,facilitating fault analysis and performance evaluation。These features significantly reduce operation and maintenance costs and extend the service life of the equipment。


4. Comprehensive Performance Parameter Comparison


ModelMeasurement AccuracyTurndown RatioCommunication protocolProtection Rating
RH-TUF-2000S±1%1000:1HART/MODBUSIP67
MTPCL-5B±1.5%500:1RS485IP65
HZ-100B±2%300:14-20mAIP65

5. Industry Applications and Value Demonstration


In the field of municipal water supply,the RH-TUF-2000S wall-mounted ultrasonic flow sensor has been successfully applied in multiple large-scale projects。Its core value is reflected in three aspects:First,improving the accuracy of water supply metering and reducing economic losses caused by "leakage";Second,optimizing the operating efficiency of pipeline networks and reducing energy consumption costs;Third,realizing intelligent data management and providing basic support for smart water utility construction。


As a professional high-tech enterprise,Xi'an Shenghongchuang Instrument Co., Ltd. has a complete R&D system and strict quality control standards。All types of flow sensor and transmitter products produced by the company have passed ISO9001 certification and comply with relevant national industry standards。When selecting suppliers,business evaluators can fully consider these qualification guarantees。


Conclusion:A Wise Investment Choice


The RH-TUF-2000S ultrasonic flow sensor integrates high-precision measurement,significant energy-saving performance,and convenient maintenance,making it an ideal solution for flow monitoring in municipal water supply systems。Its excellent cost performance and reliable performance provide business evaluators with a highly competitive choice。


Xi'an Shenghongchuang Instrument Co., Ltd. sincerely invites municipal organizations,water utility companies,and related enterprises to gain an in-depth understanding of our product solutions。Whether it is RH-TUF-2000S or other models such as HZ-100A and BST-100,we can provide you with professional technical support and customized services。Contact our sales engineers now to obtain detailed product information and technical solutions,and jointly promote the intelligent upgrade of the water utility industry。

Submit