News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

How to identify whether the PT124B-210-25MPa-R1/4 pressure transmitter is an original genuine product? A must-read guide for purchasers
Added to Favorites:125

When purchasing the PT124B-210-25MPa-R1/4 pressure transmitter, how to identify an original genuine product has become the issue of greatest concern for procurement personnel. As a professional supplier of flow control equipment, Xi'an Shenghongchuang Instrument Co., Ltd. reveals the core identification points of diffused silicon liquid and gas pressure sensors for you, providing a comprehensive analysis from origin traceability and technical performance to manufacturer qualifications, helping you avoid procurement risks and ensure equipment quality.

I. Core Identification Indicators of Original Pressure Transmitters

For high-precision pressure transmitters such as PT124B-210-25MPa-R1/4, the core characteristics of original products are reflected in three aspects: first, the packaging process of the diffused silicon chip must reach a protection rating of IP67 or above, and the weld joints should present uniform fish-scale patterns; second, the R1/4 thread of the pressure interface should comply with the ISO 1179-2 standard, with no burrs at the thread root; finally, the product nameplate must include a complete serial number and anti-counterfeiting QR code, which can be verified through the manufacturer's database. Taking the MPM489(0-6mH2O)E22B2C1G model as an example, its diffused silicon sensing element should have temperature compensation function, with an accuracy deviation not exceeding ±0.1%FS within the range of -20℃~85℃.


II. Verification Methods for Technical Performance Parameters

1.Accuracy test: use a standard pressure source to calibrate at three points: 25%FS, 50%FS, and 75%FS. The measurement error of the PS6000-BZ-A1-A-40/CD10/D transmitter should be ≤±0.075%FS
2. Temperature influence: in high-temperature 85℃ and low-temperature -40℃ environments, the zero drift of model DMP331-130-4003-1-9-999 must be <0.03%FS/℃
3. Long-term stability: after 5000 hours of continuous operation, the signal output attenuation of the original M514X-C2484E-250BG product should not exceed 0.1% of the initial value


III. Supply Chain Traceability and Qualification Review

Formal manufacturers will provide a complete chain of qualification documents, including:
• ISO 9001:2015 quality management system certification certificate
• Explosion-proof certification issued by the National Supervision and Inspection Center for Explosion-Protected Electrical Product Quality (applicable to models used in hazardous locations)
• Raw material procurement vouchers (such as procurement batch records for diffused silicon chips from GE NovaSensor, USA)
Taking the domestic ultrasonic flowmeter YSD100Y as an example, its manufacturer must possess the Pattern Approval Certificate for Measuring Instruments (CPA) for the domestic ultrasonic flowmeter YSD100Y clamp-on ultrasonic pipeline water flowmeter, and the product measurement accuracy must reach the technical index of ±1.0%.


IV. Analysis of Common Counterfeiting Methods in the Market

Procurement personnel need to be alert to the following traps:
1. Refurbished units: the casing is original, but low-cost components are replaced inside, which can be identified by checking the consistency of PCB solder joints through X-ray inspection
2. False parameter labeling: for example, falsely labeling the 25MPa range of PT124B-210 as 30MPa; a full-scale test with a piston pressure gauge is required
3. Cloned nameplates: the serial numbers of counterfeit products often cannot be verified on the manufacturer's official website, or show that they have been queried multiple times


V. Recommended Standards for Selecting Preferred Industry Suppliers

According to the 2023 evaluation by the China Instrument and Control Industry Association, high-quality pressure transmitter suppliers should meet the following requirements:
• Have more than 10 years of experience in pressure sensor R&D
• Have an independent calibration laboratory (CNAS accredited)
• Provide at least a 36-month quality warranty
• Typical cases include applications in high-end fields such as petrochemicals and power energy
For scenarios requiring simultaneous flow monitoring, it is recommended to use an ultrasonic flowmeter with accuracy better than 0.5%, such as the YSD100Y model, which supports pipe diameter measurement from DN15-DN6000mm, and its automatic memory function can trace 64 days of historical data.


VI. Final Checklist for Procurement Decision-Making

Before signing the contract, please confirm item by item:
□ The product model fully matches the required specifications (for example, whether the sealing material of the R1/4 interface is 316L stainless steel)
□ The documents included in the package contain the Chinese version of the operation manual, factory inspection report, and metrology certificate
□ A complete after-sales service network list is provided (covering at least major industrial cities in China)
□ The payment method adopts the secure model of 30% advance payment + 70% payment after goods inspection


As a pressure measurement expert with 15 years of industry experience, Xi'an Shenghongchuang Instrument Co., Ltd. reminds you that an original PT124B-210-25MPa-R1/4 pressure transmitter should demonstrate a consistent level of workmanship, and any difference in details may indicate a counterfeit product. It is recommended to purchase through officially authorized channels and request a complete performance test report. If you need more information about the technical parameters of diffused silicon sensors or high-precision flow measurement solutions, please feel free to contact our engineering technical team for one-on-one consultation.

Submit