Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
As a core component in industrial automation control, the specification parameters of the CR-YM2 pressure transmitter directly affect the measurement accuracy and stability of the system. This article focuses on the selection needs of technical evaluators and provides a detailed analysis of the key indicators of the CR-YM2 diffused silicon liquid and gas pressure sensor, including core parameters such as measurement range, output signal, and accuracy class, helping you avoid selection pitfalls and ensure compatibility matching with transmitters such as DG1300-PJ-1-CJ/GK/GK.
The standard measurement range of the CR-YM2 pressure transmitter covers 0-0.1MPa to 0-60MPa, and special customization can reach 100MPa. Compared with the MPM489E22B1C2G pressure transmitter, it adopts diffused silicon sensing technology and offers broader adaptability to liquid and gas media. During selection, key considerations include: medium corrosiveness (requiring an optional 316L stainless steel isolation diaphragm), operating temperature (-40℃~125℃ compensation range), and long-term stability indicators (annual drift <±0.1%FS). For models with alarm control such as the CLG-D pressure transmitter, it is also necessary to additionally verify the matching degree between the range and the alarm threshold.
This model provides both 4-20mA analog signal (two-wire) and RS485 digital output (Modbus protocol) versions, forming a complementary solution with the remote transmission signal scheme of the PX-BACHX pressure transmitter. During technical evaluation, attention should be paid to: signal transmission distance (analog signal recommended <500 meters), anti-interference capability (EMC compliant with EN 61326 standard), and power supply voltage range (12-36VDC). In scenarios involving transmitters such as the FST800-211P341I-10B pressure transmitter that require calibration, digital signals are more convenient for remote calibration.
According to the industry experience in the installation instructions for the KYB-C1 pressure transmitter, the CR-YM2 provides standard threaded interfaces such as G1/4 and M20×1.5, while flange connections can be customized for special requirements. During installation, note the following: avoid transmission of mechanical stress (flexible connecting pipes are recommended), install vibration-damping brackets in vibration environments, and waterproof the cable entry. For scenarios such as the JM-2010-5M pressure transmitter that require long-distance wiring, construction should be carried out in accordance with the IEC 60079-14 explosion-proof standard.
The maintenance solution for the MBS4701-060G5811 pressure transmitter is also applicable to this model: it is recommended to check the condition of sealing components every 6 months, perform zero-point calibration annually (magnetic rod operation available on site), and return it to the factory for comprehensive inspection every 3 years. Common faults include: diaphragm fouling (can be cleaned with alcohol cotton), circuit moisture ingress (IP65 protection rating verification), and signal drift (check grounding resistance <4Ω). Diagnostic experience with the BP-H pressure transmitter shows that 90% of faults originate from improper installation.
As a national high-tech enterprise in Xixian New Area, we provide: ① an ultra-long 18-month warranty (industry standard 12 months); ② free 3D installation drawings for models such as DG1300 and CR-YM2; ③ 48-hour emergency response service. For complex calibration requirements such as the FST800 series, the laboratory is equipped with a 0.05-class standard pressure source to ensure that every CLG-D pressure transmitter leaving the factory comes with an NIST traceable certificate.
Related Recommendations