News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

How many models are available for the HR-M2 pressure transmitter? Selection strategies for different application scenarios
Added to Favorites:125

HR-M2 Pressure Transmitter Model Analysis and Selection Guide

As a core component in industrial automation control, the model selection of the HR-M2 pressure transmitter directly affects system accuracy and stability. This article provides a detailed analysis of the technical parameters and selection points of mainstream models such as KYBX, DET-131, and HK-613 for different application scenarios, helping engineering procurement personnel quickly match project requirements and ensure precise and efficient equipment selection.


I. Comparison of Technical Parameters of Mainstream Models

In the field of industrial automation, pressure transmitter selection requires comprehensive consideration of measuring range, accuracy class, and media compatibility. The following is a comparison of typical models of diffused silicon Hirschmann pressure sensors:

  • KYBX Series: Specially designed for corrosive media measurement, using a 316L stainless steel diaphragm, with a measuring range covering 0-10MPa and accuracy up to 0.25%FS
  • Model DET-131: Suitable for high-temperature hydraulic systems, with medium temperature up to 400℃, standard Hirschmann connector, protection rating IP67
  • HK-613 Model: An economical solution with basic accuracy of 0.5%, suitable for non-corrosive gas measurement
  • PPM-T132F: Domestic general-purpose pressure transmitter, compatible with hydraulic/oil pressure/air pressure measurement, providing dual outputs of 4-20mA/0-10V
ModelMeasuring RangeOutput SignalTypical Applications
KYBX-KYBX0-60MPa4-20mAChemical Reactor
DET-131-0.1-25MPa0-5VHydraulic System
PPM-T132F0-100MPa4-20mA/0-10VMulti-medium measurement

II. Selection Strategies for Industrial Scenarios

According to ISO 9001:2015 equipment selection standards, the following matching factors need special attention:

1. Petrochemical Industry

Models such as ND-1 or KD-KD201 should be selected, featuring:

  • Fully welded 316L stainless steel structure, resistant to hydrogen sulfide corrosion
  • Intrinsic safety explosion-proof certification (ATEX/IECEx)
  • Medium temperature compensation range -40~400℃

2. Power and Energy Systems

The ST-ST950 or CY-CY3018 series is recommended:

  • 0.1% high accuracy class
  • Electromagnetic interference resistance design (EMC Directive 2014/30/EU)
  • Flange-mounted structure

III. Key Indicators for Procurement Decision-Making

As the contract executor, the following core parameters must be verified:

  1. Long-term Stability: Annual drift should be <±0.1%/year, for example, the BP-BP200 model has passed a 2000-hour aging test
  2. Media Compatibility: Confirm that the diaphragm material matches the chemical properties of the medium; acidic media require a Hastelloy version
  3. Environmental Adaptability: Outdoor installation requires IP68 protection rating, and models with damping adjustment should be selected for vibration scenarios

Taking PPM-T132F as an example, its wide-voltage 12-36VDC power supply characteristic is particularly suitable for mobile equipment installation, while the G1/2 threaded connection complies with the DIN 3852 standard.


IV. Industry Application Solutions

Customized selection recommendations are provided for different industry characteristics:

Aerospace Industry

Ultra-compact transmitters such as the LED-900 (weight <200g) should be selected, featuring:

  • MIL-STD-810G shock resistance certification
  • Titanium alloy diaphragm option
  • 100ms fast response

Environmental Monitoring Scenarios

The HR-M2 series with a ceramic diaphragm can measure:

  • Sludge concentration in wastewater treatment plants
  • Pressure differential in flue gas desulfurization systems
  • Corrosive chemical wastewater

V. Technical Verification and Quality Assurance

Xi'an Shenghongchuang Instrumentation Co., Ltd. ensures product reliability through the following methods:

  • Each transmitter undergoes a 72-hour temperature cycle test before leaving the factory
  • Providing third-party metrology institute calibration certificates (CNAS accredited)
  • Key components use imported diffused silicon sensor chips (original German HERTH)

Summary and Procurement Recommendations

When selecting a diffused silicon Hirschmann pressure sensor, it is recommended to follow a step-by-step verification process: first confirm the medium characteristics and range requirements, then evaluate the environmental protection rating, and finally compare the cost performance of each model. For general-purpose scenarios requiring the measurement of multiple media, Domestic general-purpose pressure transmitter PPM-T132F has become a preferred solution in industries such as petroleum and chemicals due to its wide range coverage and dual signal output characteristics.

As a high-tech enterprise in Xixian New Area, we provide full-process support from selection consultation to installation and commissioning. Contact our engineering team now to obtain customized pressure measurement solutions.

Submit