News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

FUGI-1883GC vs 1883G: Which one is better suited to your flow monitoring needs?
Added to Favorites:125

FUGI-1883GC and 1883G Core Parameter Comparison


In industrial flow monitoring scenarios, technical evaluators often need to accurately compare equipment performance parameters. As ultrasonic flow sensors in the same series, the core differences between FUGI-1883GC and 1883G are mainly reflected in three aspects: measurement accuracy, signal processing capability, and environmental adaptability.


1.1 Measurement Accuracy and Range


1883GC adopts a fourth-generation DSP digital signal processor, achieving a ±0.5% indication error (under standard operating conditions), which is a significant improvement over the ±1.0% accuracy of 1883G. In terms of range, 1883GC supports a flow velocity range of 0.01-12m/s, covering pipe diameters from DN15-DN6000, while the upper limit of applicable pipe diameter for 1883G is DN3000. For fields such as petrochemicals that require large-diameter pipe monitoring, the advantages of 1883GC are more prominent.


1.2 Signal Processing System Upgrade


The dual-channel adaptive filtering technology equipped in 1883GC can effectively suppress noise interference caused by pump valve vibration, and its signal-to-noise ratio reaches 75dB, which is 15dB higher than 1883G. Measured data shows that in an environment with level 3 mechanical vibration, the reading stability of 1883GC is improved by 40% compared with 1883G.


ParameterFUGI-1883GCFUGI-1883G
Repeatability error±0.2%±0.5%
Operating Temperature Range-40℃~+80℃-30℃~+70℃
Protection RatingIP68(Submersible)IP67

In-Depth Analysis of Application Scenarios


According to on-site application data from Xi'an Shenghongchuang Instrument Co., Ltd., the performance of the two devices differs significantly under different operating conditions.


2.1 Cost-Effective Solution of 1883G


In scenarios such as water treatment plants and HVAC systems, where the medium is stable and vibration is low, 1883G, with its high cost-performance advantage, can reduce annual maintenance costs by 25%. Its built-in temperature compensation module can effectively cope with environmental fluctuations of ±15℃, meeting the requirements of the GB/T 18604-2014 standard.


2.2 Industrial-Grade Application of 1883GC


For harsh environments such as cooling water systems in steel plants and corrosive media transmission in chemical plants, the 316L stainless steel sensor body and PTFE sealing material of 1883GC demonstrate stronger adaptability. Its unique bidirectional flow measurement function can accurately identify backflow phenomena in pipeline networks, avoiding energy waste.


System Integration and Expansion Capabilities


Modern flow monitoring systems often require deep integration with platforms such as SCADA and DCS, and the two devices each have their own strengths in communication protocol support.


  • 1883GC: Standard with dual Modbus RTU/TCP protocols, supports 4-20mA+HART output, and can be seamlessly integrated into mainstream control systems such as Siemens PCS7
  • 1883G: Provides an RS485 interface and pulse output, suitable for use with cost-effective data loggers such as SK-TUF-2000S
  • Shared Advantages: Both are compatible with ZC-TUF series converters and support on-site calibration via handheld terminals

Maintenance Cost and Life Cycle Analysis


According to 500-hour accelerated aging test data, the MTBF (mean time between failures) of 1883GC reaches 58,000 hours, which is 29% longer than the 45,000 hours of 1883G. Although the procurement cost of 1883GC is about 18% higher, in scenarios requiring 7×24-hour continuous monitoring, its total cost of ownership over 5 years is instead reduced by 12-15%.


Procurement Decision Guide


It is recommended that technical evaluators make their selection from the following dimensions:


  1. Accuracy Requirements: Give priority to 1883GC when trade settlement or compliance auditing is involved
  2. Environmental Severity: Choose 1883GC when strong vibration, corrosive media, or wide temperature fluctuation ranges are present
  3. Budget Constraints: For routine monitoring with low accuracy requirements, 1883G may be considered

Professional Recommendations and Service Support


Xi'an Shenghongchuang Instrument Co., Ltd. provides free technical selection consulting services. The engineering team can provide customized solutions based on your specific operating conditions (such as medium type, pipe material, installation conditions, etc.). At the same time, horizontal comparison data for upgraded models such as FUGI-1884G is also provided to help you establish a complete flow monitoring system.


Contact our technical consultants now: Obtain the detailed technical white paper for FUGI-1883GC and 1883G, or schedule an on-site demonstration test. Our SIN-2000H and other series products have been successfully applied to key process control nodes of large enterprises such as PetroChina and Baosteel, and their quality has undergone rigorous verification.

Submit