Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
In the field of industrial flow control,the DMK457 pressure transmitter,as the core component of a diffused silicon sensor system,has its measurement accuracy and long-term stability directly affected by the selection and configuration of its supporting equipment。This article provides an in-depth analysis of the technical characteristics of key components such as YM-1001 and PT-507,and offers full-process guidance from calibration methods to installation and commissioning。
The calibration of the YM-1001 pressure transmitter requires a focus on turndown ratio and media compatibility。This model adopts the diffused silicon principle,achieving an accuracy of ±0.1%FS within the range of 0-40kPa to 0-10MPa,making it especially suitable for high-pressure gas measurement in the petrochemical industry。During calibration,a standard instrument with an accuracy grade 3 times higher than that of the device under test must be used,and five-point calibration should be performed according to the IEC 60770 standard(0%,25%,50%,75%,100% range points)。
For applications requiring a wide turndown ratio,it is recommended to consider the Domestic Capacitive Pressure Transmitter XX-1151 Absolute Pressure Sensor Differential Pressure Transmitter,whose 40:1 turndown ratio and ±0.05% accuracy performance can meet the requirements of extreme operating conditions in the metallurgical industry。This product adopts a Hastelloy diaphragm and polyester epoxy resin encapsulation,maintaining stable output even in high-temperature corrosive media。
The wiring diagram of the YM-109 pressure transmitter must strictly follow the two-wire standard:the red lead is connected to the positive terminal of the 24V DC power supply,and the black lead is connected to the signal input terminal while also serving as the negative terminal of the current loop。In environments with strong electromagnetic interference,twisted-pair shielded cable(AWG18 specification recommended)should be used,with the shield grounded at one end to the grounding busbar of the control cabinet。When the signal transmission distance exceeds 300 meters,it is necessary to verify whether the line resistance meets the load formula Rmax=(E-10.5)/0.0236。
Attention should be paid to the installation of the PMP131-A1B01A73 supporting instrument:
Maintaining the accuracy of the FY-FY211 pressure sensor requires the regular implementation of three key maintenance tasks:zero drift calibration every 6 months(the use of the 8472.25-5717 dedicated calibration accessory is recommended),annual diaphragm sealing inspection(determined through volume change testing),and replacement of the filled silicone oil every 3 years。In environments with strong vibration,it is recommended to add a damper and set the time constant to 8-10 seconds,which can reduce the ±0.05%/g error caused by vibration。
For applications with high requirements for long-term stable operation,it is recommended that the supporting equipment for the DMK457 use the original YM-110 sensor,which adopts a military-grade diffused silicon chip and can achieve a temperature compensation accuracy of ±0.25%/55℃ within the temperature range of -40~100℃。Combined with the installation position correction function,it can eliminate zero-position errors of no more than 0.25kPa。
A complete diffused silicon sensor system should include four major modules:a pressure transmitter,a three-valve manifold,a pulsation damper,and a signal isolator。Taking steam flow measurement in the power industry as an example,a typical configuration is:PT-507 transmitter(range 0-2.0MPa)→ 316L stainless steel three-valve manifold → PMP131 display instrument → HART modem。During system commissioning,special attention must be paid to the influence of static pressure。Models with a range of 6 or above will generate a system error of -1±0.25%/6.89MPa under a static pressure of 13.76MPa,which needs to be eliminated through online calibration。
When output signal fluctuation occurs,it is recommended to troubleshoot according to the following steps:
For the DMP335 model used in explosion-proof locations,the power supply must be cut off before maintenance,and the operating procedures required by ExiaⅡCT6 certification must be strictly followed。In petrochemical units,it is recommended to conduct a full set of explosion-proof performance tests every 2 years,including housing sealing tests and verification of intrinsic safety parameters。
The DMK457 pressure transmitter supporting system construction solution detailed in this article has been successfully applied in many large metallurgical enterprises in China。Practice shows that using original YM series sensors together with a standardized calibration cycle can keep the long-term stability of the system within ±0.15%/6 months。It is recommended that users focus on key parameters such as turndown ratio,media compatibility,and explosion-proof rating during model selection,and contact the technical support team of Xi'an Shenghongchuang Instrument Co.,Ltd. for customized solutions when necessary。
Visit our technical documentation library now to obtain the complete YM-1001 pressure transmitter calibration procedure and DMK457 system wiring diagrams,or call our professional engineering team to consult on the optimal configuration solution for specific operating conditions。
Related Recommendations