Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

Domestic Ultrasonic Level Meter HJK-669 Split Type Level Meter Water Level Meter Liquid Level Meter
Updated time:Mar 08, 2024
  • Domestic Ultrasonic Level Meter HJK-669 Split Type Level Meter Water Level Meter Liquid Level Meter
  • Domestic Ultrasonic Level Meter HJK-669 Split Type Level Meter Water Level Meter Liquid Level Meter
  • Domestic Ultrasonic Level Meter HJK-669 Split Type Level Meter Water Level Meter Liquid Level Meter
  • Domestic Ultrasonic Level Meter HJK-669 Split Type Level Meter Water Level Meter Liquid Level Meter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

Split-type ultrasonic level meter, four-wire system,with built-in4-20mA and RS485 interface diagnostic module,two-line LCD display, temperature compensation available, featuring overvoltage and overcurrent protection, automatic interference suppression and other functions,welcome to purchase.

Split-type ultrasonic level meter,Features of the English four-wire split-type ultrasonic water level meter:

        1, using ABS housing, split-type installation;protection rating IP65;

        2, with the help of a two-line high-contrast LCD display and keypad, on-site operation can be performed.

        3, with built-in 4-20mA current IRS485 interface diagnostic module.

        4, all input and output lines are provided with overvoltage and overcurrent protection.

        5, ABS engineering plastic housing, protection rating IP65.

        6, built-in temperature sensor provides real-time temperature compensation for sound velocity.

        7, automatically detects on-site electrical interference and suppresses it.

        8, four response speeds are available for selection, and even if the liquid surface fluctuates violently, the average level can still be accurately read.

        9, non-contact measurement, long service life.

Content

Type

Four-wire system

Split-type

Measurement range

0-5m,0-10,0-15m,0-20m

Blind zone

0.25m-0.8m(depending on the measurement range)

Measurement accuracy

±0.3%FS*(standard conditions*

Resolution

1mm

Instrument display

English display of level and distance

Supply voltage

DC12V-36V / 80mAorAC85V-265V / 5W

Analog output

4-20mA / bit12current output load less than500Ω

Digital output

RS485interface / ModBus-RTUprotocol

Switch output

4 channels

Contact rating3A 250VAC / 5A 30VDC

Transmitter material

ABS

Probe material

Standard waterproofABS /corrosion-resistantETFE/customizedPTFE polytetrafluoroethylene probe

Electrical interface

PG11interface

Process connection

G2(customizableG1  1/2

Ambient temperature

-20℃ ~ +60 *

Process temperature

-20℃ ~ +90 *(if exceeding+60℃, please specify in remarks before ordering)

Waterproof rating

IP65

If used in a humid environment all year round, it is recommended to apply glass glue at the waterproof connector and the seam of the instrument cover

Explosion-proof rating

Exd [ia] II BT4

Process pressure

0.8  3bar / altitude less than2000m

 *FS: full scale. *Standard conditions: temperature 20℃ ± 5℃, humidity 45%75%, surrounding air still, in 1bar air.

        *When the ambient temperature is between -40℃ ~ - 20℃, the LCD cannot display and the instrument operates slowly. When the temperature is higher than -20℃, the instrument operation and LCD display return to normal.

*FS: full scale. *Standard conditions: temperature 20℃ ± 5℃, humidity 45%75%, surrounding air still, in 1bar air.

        *When the ambient temperature is between -40℃ ~ - 20℃, the LCD cannot display and the instrument operates slowly. When the temperature is higher than -20℃, the instrument operation and LCD display return to normal.

Selection and installation notes for ultrasonic water level meter:

      1, the ultrasonic level meter comes with a plastic nut. Flanges of various specifications can be customized according to user requirements.

      2, in order to prevent bracket vibration, the bracket should be thick and firm. Shock absorption measures should be considered at the fixing point between the bracket and the tank wall.

      3, recommended bracket arm length 30-50cm.

Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments.Main products include Swiss metallux ceramic pressure sensors, and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split-type level transmitters, anti-corrosion level transmitters, lightning-proof level transmitters, high-temperature guided-pressure level transmitters, rigid rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level meters


Precautions 1.All supplied products are provided with product certificates and instruction manuals, including product number, technical parameters, wiring, date of manufacture, etc. Please check carefully to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, collision, dropping, or poking the sensor with sharp tools is prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months (damage caused by improper use such as pressure overload and incorrect wiring is not covered by the quality warranty).8.Special products are customized products and do not participate in the 7-day no-reason return policy. Customized products have a delivery lead time and are not returnable or exchangeable.