Domestic Capacitive Pressure Transmitter MDM3051S-GP-AP Digital Display Transmitter Smart Differential Pressure Transmitter
Updated time:Feb 18, 2024
  • Domestic Capacitive Pressure Transmitter MDM3051S-GP-AP Digital Display Transmitter Smart Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter MDM3051S-GP-AP Digital Display Transmitter Smart Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter MDM3051S-GP-AP Digital Display Transmitter Smart Differential Pressure Transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The capacitive smart pressure/differential pressure/level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company based on many years of scientific research and practical experience.

The smart pressure/differential pressure/level transmitter is a new generation of intelligent transmitter manufactured using a sensor core produced with ROSEMOUNT technology and integrated with the advanced digital technology developed by our company. In principle, it adopts a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate temperature static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers extremely high cost performance, making it a mainstream product in the transmitter market.

This smart pressure/differential pressure/level transmitter features a novel design principle, complete varieties and specifications, convenient installation and use, and safety explosion-proof performance. It is especially renowned for high accuracy, small size, light weight, convenient adjustment, good long-term stability, strong one-way overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a very high reputation in both domestic and international markets. This series of 0.1-grade capacitive smart transmitters includes multiple types such as pressure, differential pressure, absolute pressure, remote transmission, and level, and is equipped with corresponding optional products. It can be widely used in industries such as electric power, metallurgy, petrochemical, and instrument processing, and complies with the requirements of the “IEC” standards promoted in China.


                                                                     


Product Features


·The use of a microprocessor provides greater flexibility and enhanced functions;

·Strong self-diagnosis capability;

·Wide measuring range coverage 0~0.2kPa…10MPa;

·Accuracy reaches 0.1 grade, with a turndown ratio better than 40:1;

·Zero point and span adjustment do not affect each other;

·Both remote and local span and zero point are adjustable;

·Two-wire system, compliant with HART protocol, capable of digital communication with ROSEMOUNT275 and MS-H376 handheld communicators without interrupting analog output;

·The sensor has built-in non-volatile memory;

·Good stability, high accuracy, adjustable damping, and strong one-way overload resistance;

·No mechanical moving parts, low maintenance workload, sturdy and vibration-resistant;

·All parts are universal, and interchangeability between the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact with the measured medium, explosion-proof housing structure;

·Proven superiority and reliability in the industry.


Performance Parameters


Technical Performance

Applicable media: liquid, gas, or steam

Measurement range: Range 3  0-0.2~6.0kPa

Range 4  0-6.0~40.0kPa

Range 5  0-40.0~200kPa

Range 6  0-0.16~1.0MPa

Range 7  0-0.4~2.0MPa

Range 8  0-1.6~10MPa

Output signal: linear output: 4~20mA output superimposed with HART protocol digital signal(two-wire system);

Square root output: when the input pressure is between 1.0%~100%, the output has a square root relationship with differential pressure; between 0%~0.1%, the output has a segmented linear relationship with differential pressure; there is no jump in the output between 4~20mADC, superimposed with HART? protocol digital signal(two-wire system), and users can choose linear output or square root output according to on-site conditions.

Power      supply: externally supplied 24V DC, (power supply range 14.5V~45V)

Load characteristics: maximum allowable load resistance in the load circuit Rmax=(E-10.5)/0.0236(Ω)


                 


Installation in hazardous areas: flameproof type Exd Ⅱ CT6;

               intrinsically safe type Exia Ⅱ CT6;

Load characteristics: after positive/negative shift, the upper and lower limits of its range shall not exceed the limits of the measuring range. At the minimum range, the maximum positive shift is 0.975URL; the maximum negative shift is -URL. Under square root output, the positive/negative shift can be adjusted and calibrated to 10% of the flow range.

Temperature range: medium temperature  -40~100℃

         storage temperature  -40~100℃

         complete unit operating temperature  -40~85℃

Relative humidity: 0~100%

Overpressure limit: apply 0(absolute pressure)~13.76MPa pressure to either side of the transmitter without damage; the flange can withstand 68.9MPa pressure; normal operating pressure should be from 3.45kPa(absolute pressure)to the upper limit of the transmitter range.

Volume change: less than 0.16cm3

Damping: time constant adjustable between 0.2~32.0s.

Start-up time: 3s, no preheating required.


Performance indicators:

    (under standard test conditions with no shift, 316 stainless steel isolation diaphragm, and other standard conditions.)

    Turndown ratio: 40:1

    Accuracy: for ranges 3, 4, 5

                when the turndown ratio is 1:1 to 10:1, it is ±0.1% of the calibrated range,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.05(1+0.1URL/range)% range,

                for ranges 6, 7, 8

                      when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated range,

                      when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range,

    Stability: six-month error is ±0.15% of the maximum range;

    Temperature effect: for ranges 4, 5, 6, 7, 8

                   zero error is ±0.25%/55℃ of the maximum range.

          total error including range and zero point is ±0.5%/55℃ of the maximum range.

  Note: for range 3, the temperature error should be doubled.

    Overpressure effect: after applying pressure of 140kgf/cm2, the error is ±0.25% of the maximum measuring range.

    Static pressure effect: under linear output, zero error: after applying static pressure of 140kgf/cm2, the zero error for ranges 4 and 5 is ±0.25% of the maximum measuring range, and for ranges 3, 6, 7, and 8 the zero error is ±0.5% of the maximum measuring range.

  Range error: for ranges 4, 5, 6, 7, and 8, the error is -1±0.25%/6.89MPa of the maximum measuring range, and for range 3 the error is -1.5±0.25%. This is a system error and can be eliminated by calibrating according to the actual static pressure before installation.

    Power supply effect: less than 0.005%/V of output range

    Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum measuring range.

    Load effect: as long as the voltage input to the transmitter is higher than 14.5V, there is no load effect within the load operating area.

    Installation position effect: the maximum zero error generated is not greater than 0.25 kPa, but it can be corrected and has no effect on the range;

Rotation of the measuring body relative to the flange has no effect.

    Electromagnetic radiation: complies with IEC801 standard


Appearance Structure

 Structural materials:

        Isolation diaphragm and vent/drain valve: 316 stainless steel, Hastelloy C, Monel;

    Flange and fittings: 316 stainless steel, Hastelloy C, Monel;

        “O” ring(in contact with measured medium): fluororubber, nitrile rubber, ethylene-propylene;

    Fill fluid: silicone oil;

    Bolt: carbon steel zinc-plated, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

        Electrical housing: low-copper aluminum alloy;

        Coating: polyurethane epoxy resin;

        Pressure guide connection: for ranges 3, 4, 5, thread of two-flange connection 1/4-18NPT with center hole spacing of 54mm;

          Fitting 1/2-14NPT or M20X1.5 male thread; with ball-cone sealing and fitting, center spacing is 50.8, 54, 57.2mm;

        Weight:   3.5kg(excluding options)


                                                                                                       


Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Main products include Swiss metallux ceramic piezoresistive sensors, self-developed ceramic capacitive pressure sensors, diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protected level transmitters, high-temperature pressure-guided level transmitters, rigid rod level transmitters, flange level transmitters, wind pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, and ultrasonic level gauges.



Precautions 1.All supplied products are provided with product certificates and instructions, including product numbers, technical parameters, wiring, date of manufacture, etc. Please carefully check them to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, impact, dropping, or poking the sensor with sharp tools is prohibited.4.The transmitter can work immediately after being powered on, but the output becomes stable after preheating for 30 minutes.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months(damage caused by improper use such as pressure overload or incorrect wiring is not covered by the quality warranty).8.Special products are customized products and do not participate in the 7-day no-reason return policy. Customized products have a delivery time and are non-returnable and non-exchangeable.

u=2776578472,2395865860&fm=199&app=68&f=JPEG.jpg

017b2b6174636fa2a680162ff2d3055.jpg

1fb685ae1bbc54f4b2c3b2f1778e130.jpg

Submit

Related Recommendations