Product Center

——  Product Center  ——

Product Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

Domestic Capacitive Pressure Transmitter HR-1151GP Absolute Pressure Sensor Differential Pressure Transmitter
Updated time:Feb 01, 2024
  • Domestic Capacitive Pressure Transmitter HR-1151GP Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter HR-1151GP Absolute Pressure Sensor Differential Pressure Transmitter
  • Domestic Capacitive Pressure Transmitter HR-1151GP Absolute Pressure Sensor Differential Pressure Transmitter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The capacitive intelligent pressure/differential pressure/level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company based on many years of scientific research and practical experience.

The intelligent pressure/differential pressure/level transmitter is a new-generation intelligent transmitter produced by adopting a sensor core manufactured with ROSEMOUNT technology and integrating the advanced digital technology developed by our company. In principle, it uses a direct digital capacitive circuit to replace the analog signal amplification circuit and A/D conversion circuit, and applies digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. With an extremely high cost-performance ratio, this product has become a mainstream product in the transmitter market.

This intelligent pressure/differential pressure/level transmitter features a novel design principle, a complete range of models and specifications, convenient installation and use, and safety explosion-proof performance. It is especially renowned for high accuracy, compact size, light weight, easy adjustment, good long-term stability, strong one-way overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a high reputation in domestic and overseas markets. This series of 0.1 class capacitive intelligent transmitters includes pressure, differential pressure, absolute pressure, remote transmission, level, and many other types, and is equipped with corresponding optional products. It can be widely used in industries such as electric power, metallurgy, petrochemical, and instrument processing, and complies with the "IEC" standard requirements promoted in China.


                                                                     


Product Features


·Due to the use of a microprocessor, flexibility is increased and functions are enhanced;

·Has strong self-diagnostic capability;

·Wide range coverage 0~0.2kPa…10MPa;

·Accuracy reaches 0.1 class, and the range ratio is better than 40:1;

·Zero point and range adjustment do not affect each other;

·Supports both remote and local adjustment of range and zero point;

·Two-wire system, compliant with HART protocol, capable of digital communication with ROSEMOUNT275 and MS-H376 handheld communicators without interrupting analog output;

·Built-in non-volatile memory in the sensor;

·Good stability, high accuracy, adjustable damping, and strong resistance to one-way overload;

·No mechanical transmission parts, less maintenance work, robust and vibration-resistant;

·All universal parts; interchange of the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;

·Optional diaphragm materials for contact media, explosion-proof housing structure;

·Industry-proven superiority and reliability.


Performance Parameters


Technical Performance

Applicable media: liquid, gas, or steam

Measurement range: range 3  0-0.2~6.0kPa

Range 4  0-6.0~40.0kPa

Range 5  0-40.0~200kPa

Range 6  0-0.16~1.0MPa

Range 7  0-0.4~2.0MPa

Range 8  0-1.6~10MPa

Output signal: linear output: 4~20mA output superimposed with HART protocol digital signal(two-wire system);

Square root output: within 1.0%~100% input pressure, the output has a square root relationship with differential pressure; within 0%~0.1%, the output has a segmented linear relationship with differential pressure; there is no step change between 4~20mADC output, superimposed with HART? protocol digital signal(two-wire system), and users may select linear output or square root output according to on-site conditions.

Power      supply: externally supplied 24V DC, (power supply range 14.5V~45V)

Load characteristics: maximum allowable load resistance in the load resistor circuit Rmax=(E-10.5)/0.0236(Ω)


                 


Installation in hazardous locations: flameproof type Exd Ⅱ CT6;

                intrinsically safe type Exia Ⅱ CT6;

Load characteristics: after positive and negative shift, the upper and lower limits of the range shall not exceed the range limits. At the minimum range, the maximum positive shift is 0.975URL; the maximum negative shift is -URL. Under square root output, positive and negative shift can calibrate 10% of the flow range.

Temperature range: medium temperature    -40~100℃

         storage temperature    -40~100℃

         complete unit operating temperature  -40~85℃

Relative humidity: 0~100%

Overpressure limit: applying 0(absolute pressure)~13.76MPa pressure to either side of the transmitter will not damage the transmitter; the flange can withstand 68.9MPa pressure; normal operating pressure should be from 3.45kPa(absolute pressure)to the upper limit of the transmitter range.

Volume change: less than 0.16cm3

Damping: adjustable time constant between 0.2~32.0s.

Startup time: 3s, no preheating required.


Performance indicators:

   (Under standard test conditions with no shift, 316 stainless steel isolation diaphragm, and other standard test conditions.)

    Range ratio: 40:1

    Accuracy: ranges 3, 4, 5

                  when the range ratio is 1:1 to 10:1, it is ±0.1% of the calibrated range,

                      when the range ratio is 10:1 to 40:1, it is ±0.05(1+0.1URL/range)% range,

                ranges 6, 7, 8

                      when the range ratio is 1:1 to 10:1, it is ±0.15% of the calibrated range,

                      when the range ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range,

    Stability: six-month error is ±0.15% of the maximum range;

    Temperature effect: for ranges 4, 5, 6, 7, 8

                   zero error is ±0.25%/55℃ of the maximum range.

         total error including range and zero point is ±0.5%/55℃ of the maximum range.

    Note: for range 3, the temperature error should be doubled.

    Overpressure effect: after applying pressure of 140kgf/cm2, the error is ±0.25% of the maximum range span.

    Static pressure effect: under linear output, zero error: after applying static pressure of 140kgf/cm2, zero error for ranges 4 and 5 is ±0.25% of the maximum range span, and zero error for ranges 3, 6, 7, 8 is ±0.5% of the maximum range span.

  Range error: error for ranges 4, 5, 6, 7, 8 is -1±0.25%/6.89MPa of the maximum range span, and error for range 3 is -1.5±0.25%. This is a system error and can be eliminated by calibration according to the actual static pressure before installation.

    Power supply effect: less than 0.005%/V of the output range

    Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum range span.

    Load effect: as long as the input voltage to the transmitter is higher than 14.5V, there is no load effect within the load operating area.

    Installation position effect: the maximum zero shift error generated is no greater than 0.25 kPa, but it can be corrected and has no effect on the range;

Rotation of the measuring body relative to the flange has no effect.

    Electromagnetic radiation: complies with IEC801 standard


Appearance Structure

 Structural materials:

        Isolation diaphragm and vent/drain valve: 316 stainless steel, Hastelloy C, Monel;

    Flange and joints: 316 stainless steel, Hastelloy C, Monel;

        “O” ring(in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;

    Filling liquid: silicone oil;

    Bolts: carbon steel zinc-plated, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;

        Electrical housing: low-copper aluminum alloy;

        Coating: polyurethane epoxy resin;

        Pressure connection fitting: for ranges 3, 4, 5, the screw thread of the two-flange connection is 1/4-18NPT and the center hole spacing is 54mm;

         Joint 1/2-14NPT or M20X1.5 male thread; when equipped with a ball cone sealing joint, the center spacing is 50.8, 54, 57.2mm;

        Weight:   3.5kg(excluding options)


                                                                                                       


Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Its main products include Swiss metallux ceramic piezoresistive sensors and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protected level transmitters, high-temperature guided pressure level transmitters, rigid rod level transmitters, flange level transmitters, wind pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouple/RTD temperature transmitters, ultrasonic level gauges



Notes 1.All supplied products come with a product certificate and instruction manual, including product number, technical parameters, wiring, date of manufacture, etc. Please carefully check them to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, collision, dropping, or poking the sensor with sharp tools is prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after 30 minutes of preheating.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months(damage caused by improper use such as pressure overload or wiring errors is not covered by the quality warranty).8.Special products are customized products, do not participate in the 7-day no-reason return policy, have a customization lead time, and are not returnable or exchangeable.