This intelligent single-flange level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company based on many years of scientific research and practical experience.
This single-flange level transmitter is a new generation of intelligent transmitter manufactured using sensors produced with imported technology, combined with the advanced digital technology developed by our company. In principle, it adopts a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and uses digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The complete transmitter features small size, high reliability, and good long-term stability. This product offers extremely high cost performance, making it a mainstream product in the transmitter market.
This single-flange level transmitter features a novel design principle, complete varieties and specifications, convenient installation and use, safety, and explosion-proof performance. It is especially renowned for its high accuracy, small size, light weight, convenient adjustment, good long-term stability, strong unidirectional overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a very high reputation in both domestic and international markets. This series of 0.1 grade level transmitters can be widely used in electric power, metallurgy, petrochemical, pharmaceutical, instrumentation processing, and other industries.
Product Features
·The use of a microprocessor increases flexibility and enhances functions;
·Strong self-diagnostic capability;
·Wide measuring range coverage 0~200m;
·Accuracy better than 0.1 grade, turndown ratio better than 40:1;
·Zero point and span adjustment do not affect each other;
·Both remote and local range and zero point adjustment available;
·Two-wire system, compliant with HART? protocol
·Built-in non-volatile memory in the sensor;
·Good stability, high accuracy, adjustable damping, and strong unidirectional overload resistance;
·No mechanical transmission parts, low maintenance workload, sturdy and vibration-resistant;
·All universal parts, interchangeability between the sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;
·Optional diaphragm materials for contact with the measured medium, explosion-proof housing structure;
·Industry-proven superiority and reliability.
Performance Parameters
Technical Specifications
Applicable medium: liquid
Measuring range:0-100m
Output signal: linear output: 4~20mA output superimposed with HART? protocol digital signal (two-wire system)
Power supply: external 24V DC power supply (power supply range 14.5V~45V)
Load characteristics: the maximum allowable load resistance in the load resistance circuit is Rmax=(E-10.5)/0.0236(Ω), as shown below:
Installation in hazardous locations: flameproof type Exd Ⅱ CT6
intrinsically safe type Exia Ⅱ CT6
Load characteristics: regardless of the output, after positive and negative migration, the upper and lower limits of the range shall not exceed the limits of the range. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL.
Temperature range: medium temperature -29~149℃ (silicone oil fill);
-18~204℃ (inert liquid fill); 15~315℃ (inert liquid fill);
Storage temperature -40~100℃
Complete unit operating temperature -40~85℃
-20~70℃ (with digital display head);
Relative humidity: 0~100%
Static pressure and overpressure limits: 150lb flange: 41.37kPa (absolute pressure)~1.89MPa (at 37℃, silicone oil fill)
300lb flange: 41.37kPa (absolute pressure)~4.9MPa (at 37℃, silicone oil fill)
Volume change: less than 0.16cm3
Damping: the time constant is adjustable between 0.4~32.0s (silicone oil fill).
Start-up time: 3s, no preheating required.
Performance Indexes
(under standard test conditions of no migration, 316 stainless steel isolation diaphragm, and other standard test conditions.)
Turndown ratio: 40:1
Accuracy: when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated span;
when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range;
Stability: six-month error is ±0.15% of the maximum range;
Temperature effect: zero error is ±0.375%/55℃ of the maximum range.
Including the total error of range and zero point, it is ±0.75%/55℃ of the maximum range.
Power supply effect: less than 0.005%/V of the output range
Vibration effect: on any axis, at a frequency of 200Hz, the error caused is ±0.05%/g of the maximum range span.
Load effect: as long as the voltage input to the transmitter is higher than 12V, there is no load effect within the load working area.
Installation position effect: when the pressure diaphragm is in a vertical position, the maximum zero shift error that may be generated is 0.25kPa; when the pressure diaphragm is in a horizontal position, the maximum zero shift that may be generated is 0.98kPa (for insert-type flanges, the insertion length variation shall be added), but it has no effect on the range, and this error can be corrected and eliminated.
Electromagnetic radiation: complies with IEC801 standard
Structural Materials
Diaphragm in contact with the medium, including gasket and other contact surfaces: 316 stainless steel, Hastelloy C, tantalum;
Inserted part: 316 stainless steel, Hastelloy C;
Vent/drain valve: 316 stainless steel, Hastelloy C;
Flange and connector: 316 stainless steel, Hastelloy C;
“O” ring (in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;
Mounting flange (non-contact) medium: carbon steel cadmium-plated (or 316 stainless steel);
Bolt: carbon steel zinc-plated, 1Cr18Ni9, 0Cr17Ni4CuNb, 42CrMo;
Fill liquid: silicone oil or inert liquid;
Electrical housing: low-copper aluminum alloy;
Coating: polyester epoxy resin.
Pressure connection fittings:
High-pressure side: 3″ or 4″ 150lb flange or 300lb flange;
Low-pressure side: flange connection thread 1/4-18NPT (taper pipe thread);
Connector connection thread 1/2-14NPT (taper pipe thread).
Installation and Use
Before installing and using the single-flange level transmitter, carefully read the product brochure and instruction manual in detail. During installation, the flange must not leak, and the range and wiring must be ensured correct. The housing of the level transmitter generally needs to be grounded, the signal cable must not be laid together with the power cable, and strong electromagnetic interference should be avoided around the transmitter. During use, the transmitter should be periodically verified according to industry regulations.
On-site fault inspection Most faults occurring at construction sites are caused by improper use and installation methods of the level transmitter, which can be summarized in several aspects. 1. Pipeline blockage or improper installation form, unreasonable pressure tapping point. 2. Leakage or blockage of the pressure guide pipe, residual gas in the liquid-filled pipe or residual liquid in the gas-filled pipe, and sediment in the process flange of the transmitter, forming a measurement dead zone. 3. Incorrect transmitter wiring, excessively high or low power supply voltage, and poor contact at the connection between the indicator head and the instrument wiring terminal. 4. Failure to install strictly according to technical requirements, and the installation method and site environment do not meet the technical requirements.
All of the above faults occurring in the level transmitter will cause abnormal transmitter output or inaccurate measurement. However, through careful inspection, strict use and installation according to technical requirements, and timely effective measures, the problems can be eliminated. For faults that cannot be handled, the transmitter should be sent to the laboratory or the manufacturer for further inspection.
Installation of Additional Devices
(1) In order to prevent the level transmitter from being affected by corrosion of the measured medium, or by excessive viscosity and crystallization, an isolation device should be installed;
(2) In order to ensure that the level transmitter is not affected by sudden changes in the measured medium or pulsating pressure, a buffer should be installed. Especially during sharp pressure increase and pressure drop, the level transmitter is most likely to be damaged and scrapped, and even the isolation diaphragm may rupture, causing leakage;
(3) In order to ensure that the level transmitter is not affected by the high temperature of the measured medium, a bent tube device filled with liquid should be installed;
(5) Dedicated level transmitters are strictly prohibited from other uses, and it is also strictly prohibited to perform measurement on devices without special and reliable equipment, and it is even more strictly prohibited to use ordinary level transmitters for level measurement of special media;
(6) For newly purchased level transmitters, metrological verification must be carried out before installation and use to prevent vibration, damage, or other factors during transportation from affecting the accuracy of the level instrument.
Routine Maintenance
1、Check dimensions. Only appropriate dimensions can avoid wear
2、Keep the flange clean
3、Select an appropriate location
4、Clean carefully
5、Keep dry
6、Avoid low-temperature interference
7、Prevent pressure overload
Solutions for Errors
1) The impulse pipe should be as short as possible;
2) When measuring liquid or steam, the impulse pipe should be connected upward to the process pipeline, and its slope should not be less than 1/12;
3) For gas measurement, the impulse pipe should be connected downward to the process pipeline, and its slope should not be less than 1/12;
4) The layout of liquid impulse pipelines should avoid high points in the middle, and the layout of gas impulse pipelines should avoid low points in the middle;
5) The two impulse pipes should maintain the same temperature;
6) To avoid friction effects, the diameter of the impulse pipe should be large enough;
7) There should be no gas in the liquid-filled impulse pipe;
8) When using isolation liquid, the liquids in the impulse pipes on both sides should be the same;
9) When using detergent, the detergent connection should be close to the pressure tapping port of the process pipeline, and the pipelines through which the detergent passes should have the same length and diameter, and the detergent should be prevented from passing through the transmitter.
Selection Steps
The selection of a single-flange level transmitter is very important. Below, based on my work experience, I will discuss the selection of a single-flange level transmitter.
1、The use environment of the single-flange level transmitter.
2、Range. (For details, see level transmitter parameters - range)
3、Overload pressure. (Generally, differential pressure also requires the parameter of static pressure)
4、Accuracy.
5、Medium.
6、Supply voltage.
7、Output signal.
8、Shock and vibration.
9、Pressure response.
10、Flange size.
11、Electrical interface.
12、Safety certification.
13、Other additional functions
That is mainly all. However, different transmitters may have different accessories, etc., so pay attention during selection.
After-sales Service
I. Quality Assurance Service
(I) Product quality implements the three guarantees
The product warranty period is calculated from the delivery date and is one year. During the warranty period, if there are product quality problems, our company provides free repair, replacement, and return services.
1、If general parts of the product fail and can be restored to use requirements after replacement, we are responsible for free timely repair;
2、If major parts of the product fail and cannot be repaired on time, a qualified product of the same model and specification will be replaced;
(II) Scope of exemption
During the warranty period, product failures caused by the following human factors and force majeure are not covered by free repair, replacement, and return services:
1、The use occasion is inconsistent with the parameters in the order contract;
2、Improper use by the customer causes product failure;
3、The customer repairs and modifies the product without authorization;
4、The product appearance is seriously damaged and deformed, the product identification is lost, and the product source cannot be identified;
5、Product damage caused by natural disasters such as earthquakes, floods, fires;
6、Human factors.
II. Lifetime Product Maintenance Service
For faulty products beyond the warranty period and within the exemption scope, our company will provide lifetime maintenance for your product, only charging maintenance cost and product transportation cost.
Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Main products include Swiss metallux ceramic piezoresistive sensors, self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-proof level transmitters, high-temperature guided pressure level transmitters, straight rod level transmitters, flange level transmitters, wind pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level gauges
Precautions 1.All supplied products are accompanied by product certificates and instructions, including product number, technical parameters, wiring, factory date, etc. Please carefully check them to avoid misuse. 2.Wiring should be carried out strictly in accordance with our company's instructions for use. 3.This product is a precision instrument. Random disassembly, collision, dropping, or poking the sensor with sharp tools is prohibited. 4.The transmitter can work immediately after being powered on, but the output will be stable after preheating for 30 minutes. 5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly. 6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse. 7.The quality warranty period is 12 months (damage caused by improper use such as pressure overload and wiring errors is not covered by the quality warranty). 8.Special products are customized products, do not participate in 7-day no-reason return, customization has a delivery period, no return and no exchange.