This intelligent single-flange level transmitter is a high-precision intelligent instrument product independently researched, developed, and manufactured by our company on the basis of many years of scientific research and practical experience.
This single-flange level transmitter is a new generation of intelligent transmitter produced by adopting sensors manufactured with imported technology and integrating the advanced digital technology developed by our company. In principle, it uses a direct digital capacitance circuit to replace the analog signal amplification circuit and A/D conversion circuit, and applies digital compensation technology to compensate for temperature and static pressure, thereby improving measurement accuracy and reducing temperature drift. The transmitter features compact size, high reliability, and good long-term stability. This product offers extremely high cost performance, making it a mainstream product in the transmitter market.
This single-flange level transmitter features a novel design principle, complete varieties and specifications, easy installation and use, and safety explosion-proof performance. It is especially known for high accuracy, compact size, light weight, convenient adjustment, good long-term stability, strong unilateral overload protection capability, and suitability for use in harsh environments. Therefore, it enjoys a very high reputation in domestic and international markets. This series of 0.1-grade level transmitters can be widely used in electric power, metallurgy, petrochemical, pharmaceutical, instrument processing, and other industries.
Product Features
·Due to the use of a microprocessor, flexibility is increased and functions are enhanced;
·Has very strong self-diagnostic capability;
·Wide measuring range coverage 0~200m;
·Accuracy better than 0.1 grade, turndown ratio better than 40:1;
·Zero point and span adjustment do not affect each other;
·Supports both remote and local adjustment of range and zero point;
·Two-wire system, compliant with HART? protocol
·Sensor built-in non-volatile memory;
·Good stability, high accuracy, adjustable damping, and strong resistance to unilateral overload;
·No mechanical transmission parts, less maintenance workload, sturdy and vibration-resistant;
·All universal parts, interchangeability of sensor and electronic circuit board does not affect transmitter performance, making maintenance more convenient;
·Optional diaphragm materials for wetted parts, explosion-proof housing structure;
·Industry-proven superiority and reliability.
Performance Parameters
Technical Specifications
Applicable medium: liquid
Measuring range:0-100m
Output signal: linear output: 4~20mA output superimposed with HART? protocol digital signal (two-wire system)
Power supply: externally supplied 24V DC(power supply range 14.5V~45V)
Load characteristics: the maximum load resistance allowed in the load resistor circuit is Rmax=(E-10.5)/0.0236(Ω), as shown in the figure below:
Installation in hazardous locations: flameproof type Exd Ⅱ CT6
intrinsically safe type Exia Ⅱ CT6
Load characteristics: regardless of the output, after positive and negative migration, the upper and lower limits of its range shall not exceed the limits of the range. At the minimum range, the maximum positive migration is 0.975URL; the maximum negative migration is -URL.
Temperature range: medium temperature -29~149℃(silicone oil filled);
-18~204℃(inert liquid filled);15~315℃(inert liquid filled);
Storage temperature -40~100℃
Operating temperature of the whole unit -40~85℃
-20~70℃(with digital display head);
Relative humidity: 0~100%
Static pressure and overpressure limits: 150lb flange: 41.37kPa(absolute pressure)~1.89MPa(at 37℃, silicone oil filled)
300lb flange: 41.37kPa(absolute pressure)~4.9MPa(at 37℃, silicone oil filled)
Volume change: less than 0.16cm3
Damping: adjustable time constant between 0.4~32.0s(silicone oil filled).
Startup time: 3s, no preheating required.
Performance Indexes
(under standard test conditions with no migration, 316 stainless steel isolation diaphragm, and other standard test conditions.)
Turndown ratio: 40:1
Accuracy: when the turndown ratio is 1:1 to 10:1, it is ±0.15% of the calibrated span;
when the turndown ratio is 10:1 to 40:1, it is ±0.075(1+0.1URL/range)% range;
Stability: the six-month error is ±0.15% of the maximum span;
Temperature effect: zero error is ±0.375%/55℃ of the maximum span.
The total error including span and zero point is ±0.75%/55℃ of the maximum span.
Power supply effect: less than 0.005%/V of output span
Vibration effect: on any axis, at a frequency of 200Hz, the induced error is ±0.05%/g of the maximum span range.
Load effect: as long as the voltage input to the transmitter is higher than 12V, there is no load effect within the load operating area.
Installation position effect: when the pressure diaphragm is in a vertical position, it may produce a zero shift error of up to 0.25kPa; when the pressure diaphragm is in a horizontal position, it may produce a zero shift of up to 0.98kPa(for insertion-type flanges, the insertion length variation should be added), but it has no effect on the span, and this error can be corrected and eliminated.
Electromagnetic radiation: compliant with IEC801 standard
Structural Materials
Diaphragm in contact with the medium, including gasket and other contact surfaces: 316 stainless steel, Hastelloy C, tantalum;
Insertion part: 316 stainless steel, Hastelloy C;
Vent/drain valve: 316 stainless steel, Hastelloy C;
Flange and adapter: 316 stainless steel, Hastelloy C;
“O” ring (in contact with the measured medium): fluororubber, nitrile rubber, ethylene-propylene;
Mounting flange (non-contact) medium: cadmium-plated carbon steel(or 316 stainless steel);
Bolt: cadmium-plated carbon steel、1Cr18Ni9、0Cr17Ni4CuNb、42CrMo;
Filling liquid: silicone oil or inert liquid;
Electrical housing: low-copper aluminum alloy;
Coating: epoxy resin.
Pressure connection fittings:
High-pressure side: 3″or 4″150lb flange or 300lb flange;
Low-pressure side: flange connection thread 1/4-18NPT(taper pipe thread);
Adapter connection thread 1/2-14NPT(taper pipe thread)。
Installation and Use
Before installing and using the single-flange level transmitter, carefully read the product catalog and instruction manual in detail. During installation, the flange must not leak, and the measuring range and wiring must be correct. The housing of the level transmitter generally needs to be grounded, the signal cable must not be laid together with the power cable, and strong electromagnetic interference should be avoided around the transmitter. During use, the transmitter should be periodically verified according to industry regulations.
On-site fault inspection Most faults occurring at construction sites are caused by improper use and installation methods of the level transmitter. In summary, there are several aspects. 1. Pipeline blockage or incorrect installation form, unreasonable pressure tapping point. 2. Leakage or blockage of the pressure guide tube, residual gas in the liquid-filled tube or residual liquid in the gas-filled tube, and sediment in the process flange of the transmitter, forming a measurement dead zone. 3. Incorrect transmitter wiring, excessively high or low power supply voltage, and poor contact at the connection between the indicator head and the instrument wiring terminals. 4. Failure to install strictly in accordance with technical requirements, and the installation method and on-site environment do not meet technical requirements.
Any of the above faults in the level transmitter will cause abnormal transmitter output or inaccurate measurement, but through careful inspection, strict use and installation in accordance with technical requirements, and timely effective measures, the problems can all be eliminated. For faults that cannot be handled, the transmitter should be sent to the laboratory or manufacturer for further inspection.
Installation of Additional Devices
(1) In order to prevent the level transmitter from being affected by corrosion, excessive viscosity, or crystallization of the measured medium, an isolation device should be installed;
(2) In order to ensure that the level transmitter is not affected by sudden changes or pulsating pressure of the measured medium, a buffer should be installed. Especially during sharp pressure increase and decrease, the level transmitter is most likely to be damaged and scrapped, and even the isolation diaphragm may rupture, causing leakage;
(3) In order to ensure that the level transmitter is not affected by the high temperature of the measured medium, a bent tube device filled with liquid should be installed;
(5) Dedicated level transmitters are strictly prohibited from other uses, and it is also strictly prohibited to measure on devices without special reliable arrangements, and it is even more strictly prohibited to use ordinary level transmitters for level measurement of special media;
(6) For newly purchased level transmitters, metrological verification must be carried out before installation and use to prevent vibration, damage, or other factors during transportation of the level instrument from damaging the accuracy.
Routine Maintenance
1、Check dimensions. Only appropriate dimensions can avoid wear
2、Keep the flange clean
3、Select an appropriate location
4、Clean carefully
5、Keep dry
6、Avoid low-temperature interference
7、Prevent pressure overload
Solutions for Errors
1) The impulse tube should be as short as possible;
2) When measuring liquid or steam, the impulse tube should be connected upward to the process pipeline, and its slope should not be less than 1/12;
3) For gas measurement, the impulse tube should be connected downward to the process pipeline, and its slope should not be less than 1/12;
4) The layout of the liquid impulse pipeline should avoid high points in the middle, and the layout of the gas impulse pipeline should avoid low points in the middle;
5) The two impulse tubes should maintain the same temperature;
6) To avoid friction effects, the diameter of the impulse tube should be large enough;
7) There should be no gas in the liquid-filled impulse tube;
8) When using isolation liquid, the liquid in the impulse tubes on both sides should be the same;
9) When using a cleaning agent, the cleaning agent connection should be close to the pressure tapping port of the process pipeline, and the pipelines through which the cleaning agent passes should have the same length and diameter, and the cleaning agent should be prevented from passing through the transmitter.
Selection Steps
The selection of a single-flange level transmitter is very important. Below, based on my work experience, I will talk about the selection of a single-flange level transmitter.
1、The operating environment of the single-flange level transmitter.
2、Range.(For details, refer to level transmitter parameters - range)
3、Overload pressure.(Generally, differential pressure also requires the parameter of static pressure)
4、Accuracy.
5、Medium.
6、Supply voltage.
7、Output signal.
8、Shock and vibration.
9、Pressure response.
10、Flange size.
11、Electrical interface.
12、Safety certification.
13、Other additional functions
These are the main ones, however, different transmitters may have different accessories, etc., so pay attention during selection.
After-sales Service
I. Quality Assurance Service
(I) Product quality implements the three guarantees
The product warranty period is calculated from the date of delivery and lasts for one year. During the warranty period, if there are quality problems with the product itself, our company provides free repair, replacement, and return services.
1、If general parts of the product fail and can be restored to use requirements after replacement, free scheduled repair shall be provided;
2、If major parts of the product fail and cannot be repaired on schedule, a qualified product of the same model and specification shall be replaced;
(II) Scope of exemption
During the warranty period, product failures caused by the following human and force majeure factors are not covered by free repair, replacement, and return services:
1、The usage occasion is inconsistent with the parameters of the order contract;
2、Product failure caused by improper use by the customer;
3、Customer's self-repair and modification of the product;
4、The product appearance is severely damaged and deformed, the product identification is lost, and the source of the product cannot be identified;
5、Product damage caused by natural disasters such as earthquakes, floods, fires;
6、Human factors.
II. Lifetime Product Repair Service
For faulty products beyond the warranty period and within the scope of exemption, our company will provide lifetime repair service for your product, only charging repair cost fees and product transportation fees.
Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has mainly been engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments. Main products include Swiss metallux ceramic piezoresistive sensors and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning protection level transmitters, high-temperature guided pressure level transmitters, rigid rod level transmitters, flange level transmitters, wind pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level gauges
Notes 1. All supplied products are accompanied by product certificates and instructions, including product number, technical parameters, wiring, factory date, etc. Please check carefully to avoid misuse. 2. Wiring should be carried out strictly in accordance with our company's instructions for use. 3. This product is a precision instrument. Random disassembly, collision, dropping, and poking the sensor with sharp tools are prohibited. 4. The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes. 5. If any abnormality is found during use, the power should be turned off, use should be stopped, inspection should be carried out, or contact our company's technical department directly. 6. During transportation and storage, restore the original packaging and store it in a cool, dry, ventilated warehouse. 7. The quality warranty period is 12 months(damage caused by improper use such as pressure overload and incorrect wiring is not covered by the quality warranty). 8. Special products are customized products and do not participate in the 7-day no-reason return policy. Customized products have a delivery period and are non-returnable and non-exchangeable.