I. Product Overview
The digital display instrument works with various sensors and transmitters featuring analog output to complete the measurement, conversion, display, and control of physical quantities such as temperature, pressure, liquid level, and composition
II. Functional Features
◆Error is less than 0.5%F.S, and it is equipped with calibration and digital filtering functions
◆Suitable for signal types such as standard voltage, current, RTD, and thermocouple
◆2-point alarm output, with optional high-limit alarm or low-limit alarm modes. Alarm sensitivity can be set independently
◆Transmitting output (optional), capable of outputting the measured and converted display value in the form of standard current or voltage for use by other devices
III. Technical Specifications
◆Power Supply: 85V AC~265V AC, 100VDC~380VDC, power consumption less than 6W
10VDC~36VDC, power consumption less than 6W
Note: A certain power margin should be reserved for DC power supply. Please configure the power supply according to 24VDC/0.5A, 12VDC/2A for each unit. Also pay attention to the power cable length and wire diameter.
◆Working environment: 0℃~50℃, humidity below 90%R.H, non-condensing.
◆Display range: -1999~9999, decimal point position can be set
◆Input signal type: universal input, selectable through parameter settings
◆Basic error: less than 0.5%F.S
◆Measurement control cycle: 0.2 seconds
◆Alarm output: 2-point relay output, contact capacity 220V AC, 3A
◆Transmitting output:
Photoelectric isolation, output resolution 1/3000, error less than ±0.2% F.S
For DC current or DC voltage output, please specify when ordering, load capacity greater than 600Ω.
For DC current output, 4mA~20mA, 0mA~10mA, 0mA~20mA can be selected through settings; for DC voltage output, 1V~5V, 0V~5V can be selected through settings.
0V~10V transmitting output, please specify when ordering
Transmitting output is an optional function and must be specified when ordering, otherwise the instrument does not have this function.
When externally supplying 12V and simultaneously having A1 or A2 model transmitting output function, the load capacity of the transmitting output is 450Ω
◆External power supply
Used to supply power to the transmitter, the deviation between the output value and the nominal value is less than ±5%
For other specifications, please specify when ordering
The external power supply of the instrument can only be used in conjunction with sensors or transmitters connected to the instrument