Product Center

——  Product Center  ——

Product Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

Domestic Ultrasonic Flowmeter ZRN-2000 Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
Updated time:Mar 06, 2024
  • Domestic Ultrasonic Flowmeter ZRN-2000 Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter ZRN-2000 Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter ZRN-2000 Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter ZRN-2000 Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The ultrasonic flowmeter uses the low-voltage, multi-pulse time difference principle, and adopts high-precision and ultra-stable dual-balance signal differential transmission and differential reception digital detection technology to measure the transmission time of sound waves in the downstream and upstream directions, and calculates the flow velocity according to the time difference. It features good stability, small zero drift, high measurement accuracy, a wide range ratio, and strong anti-interference capability.
 When the ultrasonic beam propagates in the liquid, the flow of the liquid will cause a slight change in the propagation time, and the change in propagation time is proportional to the flow velocity of the liquid. At zero flow, the time required for the two sensors to transmit and receive sound waves is exactly the same (the only technology that can actually measure zero flow); when the medium flows, the sound wave transmission time in the upstream direction is greater than the sound wave transmission time in the water flow direction.

 

II. Instrument Features

■ High-precision measurement
 Linearity is better than0.5%,repeatability is better than0.2%,measurement accuracy is better than±1.0%;
 ■ Wide measuring range
 By selecting different sensor models,measurement of pipeline flow for pipe diametersDN15-DN6000mmcan be achieved;
 ■ Supports Chinese and English menus
 Different versions of flowmeters,can support Chinese or English menus,making operation convenient and fast;
 ■ High reliability
 Low-voltage,multi-pulse transmission circuits are used for measurement accuracy,greatly improving service life and reliability;
 ■ Strong anti-interference capability
 Dual-balance signal differential transmission,receiving circuits are adopted,effectively resisting strong interference sources such as frequency converters,TV towers,and high-voltage lines;
 ■ Powerful memory function
 Automatically stores the cumulative flow of the previous64days,previous64months,and previous5years,automatically stores the power-on and power-off times and flow rates of the previous64events,and automatically stores whether the working status of the flowmeter was normal during the previous64days.

Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has been mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments.Main products include Swissmetallux ceramic piezoresistive sensors, and independently developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters, remote pressure transmitters, high-temperature pressure transmitters, flush diaphragm pressure transmitters, anti-corrosion pressure transmitters, integrated/split level transmitters, anti-corrosion level transmitters, lightning-protection level transmitters, high-temperature guided-pressure level transmitters, rigid rod level transmitters, flange level transmitters, air pressure transmitters, metal capacitive differential pressure transmitters, diffused silicon differential pressure transmitters, pressure controllers, thermocouples/RTDs, temperature transmitters, ultrasonic level gauges


Precautions 1.All supplied products are provided with product certificates and instruction manuals, including product model, technical parameters, wiring, factory date, etc. Please carefully check them to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Random disassembly, collision, dropping, and probing the sensor with sharp tools are prohibited.4.The transmitter can work immediately after power-on, but the output will stabilize after preheating for 30 minutes.5.If any abnormality is found during use, the power supply should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months (damage caused by improper use such as pressure overload and wiring errors is not covered by the quality warranty).8.Special products are customized products, do not participate in the 7-day no-reason return policy, have a customization lead time, and are non-returnable and non-exchangeable.



u=2776578472,2395865860&fm=199&app=68&f=JPEG.jpg

017b2b6174636fa2a680162ff2d3055.jpg

1fb685ae1bbc54f4b2c3b2f1778e130.jpg

Submit

Related Recommendations