Product Center

——  Product Center  ——

Product Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

Domestic Ultrasonic Flowmeter SDCSBS Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
Updated time:Mar 06, 2024
  • Domestic Ultrasonic Flowmeter SDCSBS Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter SDCSBS Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter SDCSBS Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter
  • Domestic Ultrasonic Flowmeter SDCSBS Clamp-on Ultrasonic Flowmeter Pipeline Water Flowmeter

Xi'an Shenghongchuang Instrumentation Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Contact Us

The ultrasonic flowmeter utilizes the low voltage, multi-pulse time difference principle, and adopts high-precision and ultra-stable dual-balance signal differential transmission and differential receiving digital detection technology to measure the transmission time of sound waves in the downstream and upstream directions, and calculates the flow velocity according to the time difference. It features good stability, small zero drift, high measurement accuracy, a wide range ratio, and strong anti-interference capability.
 When the ultrasonic wave beam propagates in the liquid, the flow of the liquid will cause a slight change in the propagation time, and the change in propagation time is directly proportional to the flow velocity of the liquid. At zero flow, the time required for the two sensors to transmit and receive sound waves is exactly the same (the only technology that can actually measure zero flow); when the medium flows, the sound wave transmission time in the upstream direction is greater than the sound wave transmission time in the water flow direction.

 

II. Instrument Features

■High-accuracy measurement
 Linearity is better than0.5%,repeatability is better than0.2%,measurement accuracy is better than±1.0%;
 ■Wide measuring range
 By selecting different types of sensors,measurement of pipeline flow for pipe diametersDN15-DN6000mmcan be achieved;
 ■Supports Chinese and English menus
 Different versions of the flowmeter,can support Chinese or English menus,making operation convenient and fast;
 ■High reliability
 Low voltage is adopted,multi-pulse transmitting circuit measurement accuracy,greatly improving service life and reliability;
 ■Strong anti-interference capability
 Adopts dual-balance signal differential transmission,receiving circuit,effectively resisting strong interference sources such as frequency converters,TV towers,and high-voltage lines;
 ■Powerful memory function
 Automatically memorizes the cumulative flow of the previous64days,previous64months,and previous5years,automatically memorizes the power-on and power-off times and flow of the previous64occurrences,and automatically memorizes whether the working status of the flowmeter was normal for the previous64days.

Since its establishment, Xi'an Shenghongchuang Instrument Co., Ltd. has been mainly engaged in the R&D and production of pressure, level, temperature, differential pressure, digital display, weighing, and flow instruments.Main products include Swissmetallux ceramic piezoresistive sensors, and self-developed ceramic capacitive pressure sensors. Diffused silicon, ceramic piezoresistive, strain gauge, metal capacitive, ceramic capacitive pressure transmitters remote pressure transmitters high-temperature pressure transmitters flush diaphragm pressure transmitters anti-corrosion pressure transmitters integrated/split level transmitters anti-corrosion level transmitters lightning-protected level transmitters high-temperature guided-pressure level transmitters straight-rod level transmitters flange level transmitters air pressure transmitters metal capacitive differential pressure transmitters diffused silicon differential pressure transmitters pressure controllers thermocouples/RTDs temperature transmitters ultrasonic level meters


Notes 1.All supplied products are accompanied by a product certificate and instruction manual, including product number, technical parameters, wiring, factory date, etc. Please carefully check them to avoid misuse.2.Wiring should be carried out strictly in accordance with our company's instructions for use.3.This product is a precision instrument. Arbitrary disassembly, collision, dropping, and poking the sensor with sharp tools are prohibited.4.The transmitter can work immediately after power-on, but the output becomes stable after preheating for 30 minutes.5.If any abnormality is found during use, the power should be turned off, use should be stopped, and inspection should be carried out, or contact our company's technical department directly.6.During transportation and storage, restore the original packaging and store it in a cool, dry, and ventilated warehouse.7.The quality warranty period is 12 months (damage caused by improper use such as pressure overload and wiring errors is not covered by the quality warranty).8.Special products are customized products, do not participate in the 7-day no-reason return policy, customized products have a delivery period, and are not returnable or exchangeable.