Warning! 4 common situations where improper installation of the YM-204FL leads to measurement errors
Added to Favorites:125

In the field of industrial liquid level measurement, the YM-204FL high-temperature guided pressure type level transmitter is a key device, and its installation accuracy directly affects measurement results. This article reveals 4 common cases in which improper installation leads to measurement errors, helping technical evaluators avoid risks, ensure the accuracy of water level measurement in high-temperature environments, and provide assurance for the stable operation of flow control systems.


I. Industry Background and Market Analysis


With the improvement of industrial automation levels, the demand for high-temperature liquid level measurement is growing day by day. As a professional high-tech enterprise, Xi'an Shenghongchuang Instrumentation Co., Ltd. has been deeply engaged in the field of flow control equipment for many years. Its self-developed YM-204FL high-temperature guided pressure type level transmitter is widely used in industries such as petrochemicals, electric power, and metallurgy, and performs particularly well in water level measurement under ultra-high-temperature environments. However, market feedback shows that about 30% of measurement errors originate from improper installation, which directly affects equipment performance and system stability.


II. 4 Common Cases of Improper YM-204FL Installation


1. Deviation in pressure guide tube installation angle: The YM-204FL achieves pressure guiding through a stainless steel cable-cylinder structure. If the angle between the pressure guide tube and the horizontal plane exceeds ±5°, it will cause uneven transmission of medium pressure. A typical case showed that, due to a 7° incline of the pressure guide tube in a chemical plant, the measurement error reached 12%. It is recommended to use a level for calibration during installation and refer to the ISO 5167-2 standard for pipeline layout.


2. Seal failure in high-temperature environments: Under operating conditions exceeding 300℃, ordinary sealing materials are prone to aging. A customer once used a non-original sealing ring, causing leakage of the YM-204FL in a high-temperature steam environment, with error fluctuation reaching ±8%. The special fluororubber sealing assembly provided by Xi'an Shenghongchuang can withstand a continuous high temperature of 400℃ and is fully matched to the extreme operating condition requirements of products in the same series such as YM-GWYW and YM-BWGYW.


3. Incorrect grounding of the cable shielding layer: Electromagnetic interference is the invisible killer of precision measurement. Technicians often overlook the principle that the shielding layer of the YM-204FL should be grounded at a single point. In one power plant, multi-point grounding introduced 50Hz power frequency interference, causing the signal output to drift by 0.5mA (equivalent to 5% of the range). The correct approach should refer to the IEC 60770-3 standard and implement equipotential grounding at the control cabinet end.


4. Medium density not calibrated: The measurement principle of the high-temperature guided pressure type level transmitter is based on the hydrostatic pressure of the medium. When the medium density deviates from the calibrated value due to temperature changes, recalibration through the HART protocol is required. In a refinery project, no density compensation was carried out for 380℃ heavy oil, resulting in a 15cm deviation in level indication. Our PT3023 series transmitters have a built-in temperature-density compensation algorithm, which can automatically correct such errors.


III. Technical Performance Comparison and Optimization Solutions


ParameterYM-204FLDB101G1EE202ZPCM262
Temperature Resistance Range-40~400℃-20~350℃-10~300℃
Accuracy Class0.25%FS0.5%FS0.35%FS
Protection RatingIP68IP67IP66

Through comparison, it can be seen that the YM-204FL has obvious performance advantages under extreme operating conditions. For customers who require higher cost performance, the UDTB series transmitters may be considered, which adopt the same pressure guiding principle but reduce cost by 20%.


IV. Standard Certifications and Installation Specifications


All Shenghongchuang level transmitters have passed the following certifications:

  • GB/T 17614-2018 Transmitters for industrial process control systems
  • ISO 9001:2015 Quality management system
  • ATEX explosion-proof certification (applicable to flammable environments)

The following must be noted during installation: the pressure guide tube length must not exceed 15 meters; avoid installation within 3 meters of vibration sources; a 72-hour aging test must be carried out before commissioning. We provide an installation guide manual compliant with the API RP 551 standard, covering the special requirements of the full product series including HSBG-E7100A2K1W2.


V. Why Choose Xi'an Shenghongchuang


As a leading sensor manufacturer in Northwest China, we have:

  1. A production base in a national-level new area, equipped with a fully automatic calibration system
  2. A 24-hour technical response team, providing full-process support from model selection to installation
  3. A ten-year warranty commitment, with all YM-FBYW series products enjoying free calibration services

Contact our engineering team now to obtain customized level measurement solutions. Visit our official website or call 029-XXXXXXX to get the white paper "Selection Guide for Level Sensors Under High-Temperature Operating Conditions" for free (including detailed comparative data of YM-204FL and PT3023).

Submit