Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
During the wastewater treatment process, the LY-LDE-B electromagnetic flowmeter becomes a key device thanks to its high-precision measurement and stable performance. This article will share practical application cases of this model and the LY-LDE series (including LY-LDE-A, LY-LDE-C, etc.) in wastewater flow monitoring, and analyze how its corrosion-resistant design and no-pressure-loss advantages help technical evaluators optimize process flows.
Flow monitoring in wastewater treatment plants directly affects process control and discharge compliance. Traditional mechanical flowmeters are easily worn by impurities in wastewater, while the LY-LDE-B electromagnetic flowmeter adopts a non-contact measurement principle, with a PTFE or rubber lining that can withstand corrosive media with a pH value of 2-12. After a wastewater treatment plant in a coastal city adopted the XFC electromagnetic flowmeter to replace the turbine flowmeter, annual maintenance costs decreased by 62%, and the data fluctuation rate dropped from ±5% to ±0.8%.
In a wastewater plant renovation project in an industrial park in Shaanxi, the technical team faced difficulties in measuring high-concentration organic wastewater. Xi'an Shenghongchuang customized the LY-LDE-WS electromagnetic flowmeter for the project, equipped with 316L electrodes and a double-layer PTFE lining, and integrated the data into the central control system through the MODBUS-RTU protocol. After project implementation, the dosing accuracy of chemical agents increased by 40%, saving more than 800,000 yuan in annual treatment costs.
Technical evaluators often fall into the misunderstanding that "the higher the accuracy, the better". In fact, although the 0.2-class accuracy of the HPLDE electromagnetic flowmeter is better than the 0.5-class accuracy of the JCLDBE, it requires a higher-cost excitation system and signal processor. We recommend prioritizing actual operating condition parameters such as medium conductivity (>5μS/cm) and flow velocity range (0.3-10m/s) according to the ISO 9104 standard.
With the implementation of the "Water Pollution Prevention and Control Action Plan", the intelligent LY-LDE-A electromagnetic flowmeter is integrating AI diagnostic functions. Its equipped XFE series sensors independently developed by Shenghongchuang can predict pipeline sedimentation through vibration spectrum analysis and trigger the flushing program in advance. The 2023 industry report shows that the market share of electromagnetic flowmeters with predictive maintenance functions increased by 27% annually.
As a national high-tech enterprise, we have 23 patents related to electromagnetic flowmeters, and all products have passed CE and SIL2 certification. The production base in Xixian New Area is equipped with German KROHNE calibration devices, ensuring that the factory accuracy of each LY-LDE electromagnetic flowmeter is better than ±0.3%. Technical evaluators are welcome to call 400-XXX-XXXX to obtain the "White Paper on Wastewater Treatment Flow Monitoring Solutions".
Related Recommendations