LDD electromagnetic flowmeter under high-temperature conditions performance test report,the results were beyond expectations!
Added to Favorites:125

Flow Measurement Challenges Under High-Temperature Conditions


In industries such as petroleum and petrochemical,metallurgy and other sectors,the proportion of operating conditions with medium temperature exceeding 150℃ is as high as 32%(according to the SGS 2023 industry report)。Traditional electromagnetic flowmeters such as the HQLDE-C series often have problems such as electrode polarization and weld deformation in this environment,causing measurement error to increase to ±5%FS。The Xi'an Shenghongchuang technical team improved the molecular structure of the PTFE weld lining,enabling the LDD electromagnetic flowmeter to still maintain ±0.5% accuracy during continuous operation at 200℃,and this breakthrough has obtained a national invention patent(ZL202310256789.X)。


Core Technical Innovation Analysis


Comparative testing shows that the triple-protection system adopted by the LDD series is significantly better than similar products:① Nanocrystalline alloy electrodes reduce the electrochemical corrosion rate by 83%;② The patented cooling wire design(patent no. ZL202210458632.1)keeps coil temperature rise within 45K;③ The dynamic compensation algorithm corrects in real time the impact caused by viscosity variation。In the 180℃ high-viscosity acidic medium test,the drift of the LDD electromagnetic flowmeter after continuous operation for 2000 hours is only 0.2%,while the same-series HQLDJ model drifts to 1.8%。


Key Performance Parameter Comparison


ModelTemperature limit(°C)High-temperature accuracyMTBF(hours)
LDD electromagnetic flowmeter200±0.5%50,000+
HQLDE-DC150±1.2%28,000
LDW electromagnetic flowmeter180±0.8%35,000

Typical Application Scenario Validation


In a tar metering project at a coking plant in Shaanxi,the LDD electromagnetic flowmeter successfully replaced the existing HQLDG model:① Under pipeline temperature 195℃ conditions,annual maintenance frequency dropped from 6 times to 1;② Downtime cost caused by metering disputes was reduced by 72%;③ Together with Shenghongchuang's SC-8000 control system,energy consumption was optimized by 11.6%。This case was selected as an excellent application case of the China Automation Association in 2023。


Selection Decision Guide


Technical evaluation personnel need to focus on:① Whether the process medium temperature exceeds the 120℃ critical point;② Whether there is a highly corrosive combination(such as high temperature+high-concentration dissolved ions);③ Whether HART / Profibus communication protocol is required。For choosing between the LDC and LDD series,when the temperature>160℃ it must be the D series special cooling version。


Why Choose Shenghongchuang


As a high-tech enterprise that is a key development focus in Xixian New Area,we have:① a CNAS-certified laboratory capable of simulating extreme-condition tests;② a 24-hour responsive technical expert team;③ 3-year extended warranty service。By consultation,you can obtain the complete test report and the《High-Temperature Flow Measurement Solution White Paper》,call 029-8856XXXX or visit www.sensor-tech.cn to get an exclusive selection solution。