Did a sudden failure of the CHLET-1 sensor cause abnormal tension and compression measurement? As the core monitoring equipment of a reaction copper mixing station, the accuracy of the column-type force sensor directly affects production safety. In this article, Xi'an Shenghongchuang technical experts share a 3-step rapid diagnosis method, covering key troubleshooting points for common models such as CKY-118 and EX302B, helping you quickly restore the measurement accuracy of load cells such as ET-2 and BLR-ZSA.
In industrial scenarios such as reaction copper mixing stations, column-type force sensors such as CHLET-1, ET-2, and CKY-118 undertake critical tension and compression measurement tasks. The accuracy of these sensors is directly related to the stability and safety of the production process. Once a sensor fails, it may lead to the following problems:
According to industry statistics, about 35% of industrial accidents are related to sensor failures, among which abnormal tension and compression measurement accounts for the highest proportion. Therefore, rapidly and accurately diagnosing sensor failures is of vital importance.
For column-type force sensors such as CHLET-1 and EX302B, a visual inspection should first be carried out:
For models such as BLR-ZSA and YY-L103, special attention should also be paid to the waterproof performance of cable connections. According to the GB/T 7551-2008 standard, the enclosure protection rating of the sensor should reach IP65 or above.
Use a multimeter to perform basic electrical tests:
For models such as NR-LB2 and CZL-3, it is also necessary to check whether the excitation voltage is stable(usually 10V DC). If any abnormality is found, it is recommended to stop using it immediately and contact professional technicians.
Conduct load testing using standard weights or a force testing machine:
According to the JJG 391-2009 verification regulation, the nonlinearity error of load cells such as XL-G2 should be ≤0.05%FS. If the test result exceeds this range, it indicates that the sensor needs calibration or replacement.
Based on Xi'an Shenghongchuang's 15 years of industry experience, the typical failures of column-type force sensors are summarized as follows:
To ensure the long-term stable operation of sensors such as LK-1016 and XL-G2, it is recommended to:
As a national high-tech enterprise, Xi'an Shenghongchuang provides technical support, calibration services, and spare parts supply for the full range of sensors such as CHLET-1. Our technical team has 20 years of industry experience and can provide customized solutions according to your specific working conditions.
Through the 3-step diagnosis method introduced in this article, you can quickly identify the causes of failures in column-type force sensors such as ET-2, CKY-118, and EX302B. Remember:
If you encounter complex failures in sensors such as BLR-ZSA and YY-L103, or need professional technical support for the CHLET-1 sensor, please contact Xi'an Shenghongchuang Instrument Co., Ltd. immediately. Call our service hotline 400-XXX-XXXX, or visit our official website www.xxxxxx.com for more solutions.