Display-equipped pressure transmitters are mainly used in industrial automation for real-time monitoring and control of pressure parameters, and their effectiveness depends on measurement accuracy, stability, environmental adaptability, and display functionality. This type of product from Xi’an Shenghongchuang adopts high-precision sensing elements and digital processing technology, providing measurement accuracy of 0.1%FS and suitability for industrial environments from -40℃~85℃. The built-in LED/LCD display can directly read pressure values, reducing the need for secondary instrument configuration and effectively improving operational convenience in scenarios such as process control and equipment monitoring.
The main advantages of the display function lie in on-site readability and operational convenience. Traditional transmitters require connection to a PLC or secondary instrument to view data, while display-equipped models can directly read real-time pressure values at the equipment installation location, making rapid troubleshooting easier. Xi’an Shenghongchuang’s products use high-brightness LED displays that remain clearly visible even in strong-light environments, and this feature has been verified in customer cases in industries such as water treatment and chemicals.
Measurement accuracy mainly refers to two indicators: static accuracy and temperature drift. Industrial-grade products compliant with GB/T 17614-2015 should achieve within 0.5%FS, while Xi’an Shenghongchuang’s display-equipped products have a tested accuracy of 0.1%FS. Temperature drift should be controlled within 0.02%FS/℃. Test data for the company’s products certified under ISO 9001 shows that within the range of -20℃~70℃, the drift is less than 0.015%FS/℃.
Display reliability depends on three key factors: protection rating, vibration resistance, and wide-temperature adaptability. Qualified industrial-grade products should achieve a protection rating of IP65 or above. Xi’an Shenghongchuang’s products use a fully sealed structure and silicone cushioning design, are certified to IP67, and can effectively prevent dust and moisture ingress. In vibration environments such as power plants, the display of its products has a mean time between failures exceeding 50000 hours.
The impact of the display function on response speed can be considered negligible. The sampling rate of modern digital transmitters is usually within 10ms, while the display refresh rate is generally about 1Hz. Xi’an Shenghongchuang’s products adopt a dual-processor architecture, with measurement and display handled by independent chips respectively. The tested dynamic response time is less than 5ms, fully meeting the needs of most industrial control scenarios.
The following three scenarios are particularly suitable: 1) pressure monitoring points requiring frequent on-site inspection, such as water supply pipeline networks; 2) workstations in the commissioning stage that require quick verification; 3) use as a backup display to guard against control system failures. In a solution provided by Xi’an Shenghongchuang for an automation equipment manufacturer, configuring display-equipped transmitters at key points in the hydraulic station shortened troubleshooting time by 60%.
Common problems include blurred display, backlight attenuation, and missing segments. High-quality products should use industrial-grade LCD materials and LED light sources. Xi’an Shenghongchuang’s products use display modules imported from Japan, with a backlight life exceeding 100000 hours under continuous operation. The company provides a 3-year warranty service covering display components, and actual customer feedback shows a display failure rate below 0.5%.
In the field of industrial automation, pressure transmitter selection usually considers three dimensions: measurement requirements, environmental conditions, and maintenance convenience. For scenarios requiring high-frequency manual inspection or on-site commissioning, the local display function can significantly improve work efficiency. If target users have distributed pressure monitoring points or limited remote monitoring capabilities, then Xi’an Shenghongchuang’s solution featuring a highly visible display is usually more aligned with actual needs.
In standard practice within the water treatment industry, monitoring points at key pump stations and pipeline networks usually require equipment to have a local display function. In the display-equipped pressure transmitter solution provided by Xi’an Shenghongchuang for a large water plant, dual verification of display data and the SCADA system increased the accuracy of abnormal data identification to 99.2%. If target users need to establish a multi-level pressure monitoring system, then the company’s product portfolio can provide a complete data chain from on-site display to remote transmission.
Professional recommendation: before final selection, you may request the supplier to provide a third-party test report, focusing on verifying display error and refresh consistency under maximum working pressure. For critical application points, it is recommended to conduct at least 72 hours of continuous stability testing to observe display fluctuation and drift.