News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

Technical Evaluation Must-Read: 3 Pitfalls 90% of People Encounter When Selecting a DY-X Pressure Transmitter
Added to Favorites:125

Introduction

During the DY-X pressure transmitter selection process, 90% of technical evaluators fall into three major misconceptions: measurement range, media compatibility, and signal output. As the core component of diffused silicon liquid and gas pressure sensors, improper selection will directly affect system accuracy and stability. This article reveals these common pitfalls to help you avoid risks and precisely match application requirements.


Misconception 1: Ignoring media compatibility leads to a sharp reduction in sensor service life

In corrosive environments such as petroleum and natural gas, chemical engineering, and metallurgy, the diaphragm material selection of the DY-X pressure transmitter is critically important. We once encountered a customer who used an ordinary stainless steel sensor to measure hydrochloric acid media, and diaphragm perforation occurred in just 3 months. Diffused silicon liquid and gas pressure sensors must match materials according to media characteristics:

  • Strong acid/strong alkali environments: 316L stainless steel or Hastelloy diaphragms are recommended. For example, the special alloy steel material used in Domestic weighing sensor HVC-P04 corrugated tube weighing force sensor spring pressure machine sensor remains stable within a pH value range of 1-14
  • High-temperature oil media: The ET-A series with heat dissipation fins should be selected, with a working temperature up to 150℃
  • Viscous liquids: The flat diaphragm structure of model MS-MS132 can prevent medium crystallization and blockage

Technical parameters show that when the media temperature exceeds 65℃, special attention must be paid to the sensor's zero point temperature effect (±0.03%FS/℃) and output temperature effect (±0.03%FS/℃), otherwise it will cause measurement value drift.


Misconception 2: Improper measurement range selection causes accuracy failure

A steel enterprise once used a 0-10MPa PN-M2 pressure transmitter to measure 0.5MPa compressed air, resulting in an actual error of 2.5%, far exceeding the permitted 0.5%FS. This is because:

Range selection ratioActual accuracy lossSolutions
Range >10 times working pressureAccuracy decreases by 40-60%Choose YBS-S100 for customizable 0-1MPa range
Range <1.5 times working pressureOverload risk increases by 300%PMP-PMP317 series with 150% safe overload

It is recommended to follow the "1/3-2/3" principle: for conventional working conditions, choose models with operating pressure between 30%-60% of the sensor range, such as the finely divided specifications of the DY-X series including 0-2.5MPa and 0-6MPa. For impact load scenarios, the buffered design version of model HB-S should be selected.


Misconception 3: The signal output method does not match the system

The most common conflict during on-site commissioning is incompatibility between the sensor output signal and the PLC module:

  1. 4-20mA analog signal: Suitable for the CEQ-CEQ1300 basic model with a distance <500m, but note that the line resistance must be ≤600Ω
  2. RS485 digital signal: The MBC-1 manual states that it supports a maximum network of 32 nodes, and the baud rate must be set to 9600bps
  3. HART protocol: The PCM-D installation manual emphasizes that a 250Ω terminal resistor must be configured

In smart factory construction, we recommend using the DY-XV2.0 version that supports IO-Link, with a transmission rate of 230.4kbps and remote parameter configuration capability. If you need to monitor multiple devices at the same time, you may refer to the multi-channel acquisition solution of Domestic weighing sensor HVC-P04.


Selection decision tree and response to special working conditions

For special industries such as water conservancy and electric power, thermal power, and papermaking, the following factors must also be considered:

Key points for selection in vibration environments

Under construction machinery working conditions, the potting seal structure recommended in the MBC-1 manual should be selected, with vibration effect <0.1%FS (10-2000Hz). Comparative tests show that ordinary structures will produce 0.5% measurement fluctuation under 50Hz vibration.

Explosion-proof certification requirements

The petroleum and natural gas industry must select the explosion-proof version of MS-MS132 with ATEX/CSA certification, whose flameproof gap is strictly controlled between 0.15-0.2mm. We once assisted an oilfield project in passing the Ex d IIC T6 certification of CEQ-CEQ1300.


Summary and professional recommendations

From the above analysis, it can be seen that the selection of DY-X pressure transmitters requires comprehensive consideration of three dimensions: media characteristics, range matching, and signal transmission. As a national high-tech enterprise, Xi'an Shenghongchuang Instrumentation Co., Ltd. provides:

  • Free working condition analysis services (including media corrosivity testing)
  • On-site calibration service for YBS-S100 pressure transmitters
  • A complete set of installation guidance documents for the PCM-D series

Contact our technical team now to obtain customized selection solutions and an industry application case collection. For scenarios requiring high-precision force measurement, you may also learn about the special application solutions of Domestic weighing sensor HVC-P04 in the aerospace field.

Submit