News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

3 major selection pitfalls of insertion-type PTFE-lined rubber flow meters: A must-read guide for project managers
Added to Favorites:125

In the selection of flow control equipment, insertion-type fluororubber-lined flow meters are highly favored for their corrosion resistance, but misunderstandings often exist in the selection of models such as HKTMF and JYLDE regarding media compatibility and installation specifications. This article focuses on 3 major selection blind spots commonly seen by project managers, and combines engineering application data from typical models such as the TOP-101 series to provide key decision-making references for quality control and engineering teams.

Misconception 1: Ignoring chemical compatibility of the medium and blindly relying on fluororubber material

Although insertion-type fluororubber-lined flow meters (such as the HKTMF and JYLDE series) are well known for corrosion resistance, the corrosiveness of different media to materials varies significantly. In one chemical project, failure to detect trace hydrofluoric acid in the medium caused the lining layer of model 93454-543 to swell within 3 months, resulting in flow data drift. In actual model selection, key attention should be paid to:

  • Medium composition analysis: Strong oxidizing agents (such as concentrated nitric acid) may corrode the molecular chains of fluororubber, requiring specially treated models such as TOP-101-32
  • Temperature impact: When exceeding 150℃, the sealing performance of model 93636-135 will decrease by 12%-15%
  • Dynamic wear: For media containing solid particles, it is recommended to use the thickened lining design of the XDL-DC series

According to ASTM D543 standard test data, model 142654-775 performs excellently in a 98% sulfuric acid environment, but its service life is shortened by 40% in ethyl acetate.

Misconception 2: Mismatch between installation position and fluid dynamics characteristics

Field tests of the TOP-101-25 electromagnetic flow meter in a DN300 pipeline show that when installed less than 5 pipe diameters away from a bend, the measurement error can reach ±3.2%. Common installation blind spots include:

Installation scenariosRecommended ModelsMinimum straight pipe length requirement
Turbulent flow zone after the pump93718-35310D(with flow conditioner)
Vertical pipelineTOP-101Full-pipe status detection module required

A case at a wastewater treatment plant shows that after correctly selecting model 93636-135 and meeting the installation requirements of 10D upstream and 5D downstream, metering accuracy improved from ±2.5% to ±0.8%.

Solutions for special operating conditions

For media containing bubbles (such as beer filling lines), the multi-electrode design equipped in the XDL-DC series can effectively suppress signal fluctuations. For high-viscosity fluids in the pharmaceutical industry (such as glycerin), the trapezoidal flow passage cross-section design of model 93454-543 is required.

Misconception 3: Failing to consider long-term maintenance costs and spare parts interchangeability

An audit report from an energy group pointed out that although model TOP-101-32 had a 15% lower procurement cost, its dedicated flange structure led to maintenance costs 210% higher than standard models. Key considerations include:

  1. Electrode replacement cycle: The JYLDE series requires replacement on average every 2 years in wastewater treatment, while HKTMF uses platinum-iridium alloy that can extend service life to 5 years
  2. Spare parts inventory pressure: The seals of 93718-353 and 142654-775 are interchangeable, reducing storage costs
  3. Calibration convenience: The TOP-101 series supports online calibration, saving 60% of downtime compared with traditional models

Selection decision support system

Based on 20 years of industry experience, Xi'an Shenghongchuang Instrumentation Co., Ltd. provides a complete selection solution including medium analysis → operating condition simulation → full life-cycle cost evaluation. Our TOP-101 series electromagnetic flow meters have passed ISO 9001:2015 certification and have served 300+ key projects in fields such as petrochemicals and pharmaceuticals.

To obtain a customized selection report immediately, please contact the technical team:
Phone: 029-XXXXXXX | Email: service@xxxxx.com

Frequently Asked Questions

Q: How to choose between fluororubber lining and PTFE lining?
A: PTFE is suitable for higher temperatures (≥180℃) but has relatively poor flexibility, while fluororubber (such as model 93636-135) is more reliable under vibrating operating conditions.

Q: Can insertion-type flow meters be used in small-diameter pipelines?
A: For pipelines below DN50, it is recommended to use the XDL-DC miniature sensor, with a minimum measurable flow velocity of 0.3m/s.

Submit