In the field of industrial flow measurement, the ZC-TUF-2 wall-mounted ultrasonic flow sensor stands out with its outstanding performance. As a flagship product of Xi'an Shenghongchuang Instrument Co., Ltd., it precisely addresses the three core pain points in pipeline flow detection: signal stability, media adaptability, and data accuracy, making it an ideal upgrade choice for series such as TDS-100P and FR-500H.
In industrial environments, electromagnetic interference and mechanical vibration often cause data drift in traditional flowmeters. The ZC-TUF-2 adopts the following innovative designs to ensure signal stability:
Measured data shows that in a steel plant circulating water system, the data fluctuation amplitude of the ZC-TUF-2 during 30 consecutive days of operation is only ±0.2%, significantly better than the ±0.5% of the comparable FR-500H model.
From corrosive chemical liquids to sewage containing bubbles, different media characteristics place differentiated requirements on ultrasonic measurement. The ZC-TUF-2 solution includes:
Three probe options are available: standard type, anti-corrosion type (PTFE coating), and high-temperature type (-40℃~200℃), covering 95% of industrial fluid scenarios. Compared with the single-probe design of FUGI-1881X, media compatibility is improved by 3 times.
The built-in sound velocity database can automatically match parameters for 800+ common media. When special solvents such as DMSO are detected in chemical pipelines, the system dynamically adjusts the emission frequency (1MHz~5MHz) to ensure signal penetration.
Through the following technical matrix, the ZC-TUF-2 achieves class 0.5 accuracy (ISO 4064 standard):
In municipal water supply pipeline network verification, parallel testing with the SC-TUF-2000H shows that when the flow rate is 300m³/h, the indication error of the ZC-TUF-2 is only 0.3m³/h, meeting the highest accuracy requirements of GB/T 18604-2014.
As an upgraded replacement solution for DX-TUF-2000H, the ZC-TUF-2 has established benchmark cases in multiple fields:
Xi'an Shenghongchuang Instrument Co., Ltd. has been deeply engaged in the field of flow control equipment for 15 years. The ZC-TUF-2 wall-mounted ultrasonic flow sensor integrates the technical accumulation and field experience of the JY-TUFH series, providing technical evaluators with:
If you need comparative parameters for models such as TDS-100P and FR-500H, or an OEM solution for the ZC-TUF-2, please contact our engineering technical team immediately.