Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
As the core component of the YM-115 pressure transmitter, the stability of the diffused silicon sensor directly affects the accuracy of industrial flow control. This article focuses on 5 common types of diffused silicon sensor faults in YM-115 pressure transmitters, including calibration abnormalities in the YSZK-01G-C model and display faults in the DMK331-250-4000, providing professional solutions to help technical evaluators quickly diagnose issues and restore optimal equipment performance.
During use, the YSZK-01G-C pressure transmitter may experience calibration abnormalities, mainly manifested as output signals that do not match the actual pressure value. These problems are usually caused by the following reasons:
Solution: First, check whether the power supply is stable, and it is recommended to use a regulated power supply. Second, perform zero calibration and full-scale calibration according to the manual. If the problem still exists, the sensor chip may need to be replaced.
Common display faults in the DMK331-250-4000 pressure transmitter include no display, fluctuating display values, or display error codes. These problems may be caused by:
Solution: First, check whether the wiring of the display module is loose or oxidized. Second, measure whether the sensor output signal is normal. If the display module is damaged, it is recommended to replace it with a new one.
Calibration of the YMP-YMP489 pressure transmitter is a key step in ensuring measurement accuracy. The correct calibration procedure includes:
It should be noted that the ambient temperature for calibration should be maintained at 20±5℃, and the humidity should not exceed 85%RH. After calibration is completed, it is recommended to conduct at least 3 repeatability tests to ensure the reliability of the calibration results.
According to different measuring media, YM-1KGR pressure transmitters are mainly divided into the following types:
Choosing the appropriate model is crucial for ensuring measurement accuracy and equipment service life. It is recommended to select a suitable model based on actual operating conditions.
Display abnormalities in the MBS-G3131 pressure transmitter may be manifested in the following situations:
Diagnostic steps: First, check whether the power supply voltage is within the rated range; second, check whether the sensor connection is good; finally, check whether the sensor itself is damaged. Handling solutions include recalibration, replacing the connection wire, or replacing the sensor.
This article подробно introduces common faults and solutions of diffused silicon sensors in YM-115 pressure transmitters. As a professional product of Xi'an Shenghongchuang Instrumentation Co., Ltd., our pressure transmitters use high-quality diffused silicon sensors to ensure measurement accuracy and stability. If you would like to learn more technical details or obtain professional support, please feel free to contact our technical team at any time.
Contact us now: 400-xxx-xxxx, or visit our official website for more product information and technical support.