TS-TS203 Pressure Transmitter Calibration Guide: Key Steps to Improve the Accuracy of Diffused Silicon Sensors
Added to Favorites:125

As the core product of diffusion silicon sensors, the precise calibration of the TS-TS203 pressure transmitter directly affects the reliability of industrial flow control. This article, written by experts from Xi'an Shenghongchuang Instrumentation Co., Ltd., explains in detail the 8 key steps for calibrating diffusion silicon liquid and gas pressure sensors, helping engineers master the maintenance points of products in the same series such as PTB505 and TS-TS201, and improve the measurement accuracy of customized models such as 7MF-MF1567.


The Importance of Diffusion Silicon Sensor Calibration


In the field of industrial flow control, the accuracy of pressure transmitters is directly related to production safety and efficiency. Diffusion silicon sensors, due to their excellent stability and sensitivity, have become the core components of models such as TS-TS203 and PTB505. However, as usage time increases, sensor performance may drift. Data shows that for diffusion silicon sensors without regular calibration, the measurement error can reach as high as 2.5%FS, which will cause serious hidden dangers for industries such as chemicals and energy that require precise flow control. Through 10 years of industry practice, Xi'an Shenghongchuang Instrumentation Co., Ltd. has found that adopting a calibration process based on ISO/IEC 17025 standards can improve the long-term stability of models such as TS-TS204 by more than 60%.


Detailed Explanation of the 8 Key Steps for TS-TS203 Calibration


Step 1: Environmental Preconditioning. Place the TS-TS203 pressure transmitter in the calibration environment for at least 2 hours to ensure thermal equilibrium between the sensor and the medium. Diffusion silicon elements are temperature-sensitive, and it is recommended to use the domestic TK70 temperature transmitter for real-time monitoring, whose ±0.15℃ accuracy can meet the requirements of the GJB2244A-2011 standard.


Step 2: Zero-Point Calibration. Under no-pressure conditions, adjust the 4mA output point through a HART communicator. Special note: for models such as TS-TS201 with alarm control, the alarm threshold must also be calibrated simultaneously.


Step 3: Full-Scale Calibration. After applying the rated pressure, adjust the 20mA output point. For diffusion silicon sensors, it is recommended to use the stepwise pressurization method, with each pressurization not exceeding 25% of the range, which is consistent with the preloading principle in the PTB505 installation instructions.


StepsTechnical key pointsRelated Models
Linearity CalibrationTest at 25%、50%、75% range pointsTS-TS204/NPT102
Temperature Compensation-20℃~80℃ Environmental Test7MF-MF1567 Customized Model

Comparative Analysis of Industry Applications


In the petrochemical field, the explosion-proof design of TS-TS203 is superior to the basic LPB8400 model; while 7MF-MF1566 is more favored in the food and pharmaceutical industry because of its 316L stainless steel material. Customer cases of Xi'an Shenghongchuang show that the TS-TS204 remote transmission model using a customized calibration solution has reduced the annual failure rate in long-distance pipelines to 0.3 times/thousand units.


Common Misunderstandings and Professional Recommendations


Misunderstanding 1: Only performing two-point calibration. In practical applications, the linearity at intermediate range points is equally critical. We recommend performing at least 5-point verification for the PTB series.


Misunderstanding 2: Ignoring medium influence. Gas and liquid calibration require different methods, especially for small-range models such as 7MF-MF1564.


Why Choose Shenghongchuang


As a high-tech enterprise in Xixian New Area, we have a CNAS-certified calibration laboratory and can provide calibration services compliant with the GB/T 17614 standard for the entire series of products such as TS-TS203. Combined with the coordinated monitoring of the TK70 temperature transmitter, we ensure that your sensor system achieves optimal performance. Contact our technical team now to obtain an exclusive calibration solution.