Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
Among many diffused silicon pressure transmitters,why can SY-PG1300-1.6MPa stand out?As a pressure sensor using advanced diffused silicon technology,what advantages does it actually have in accuracy,stability and cost performance?This article will provide an in-depth review of this highly acclaimed PT124B series pressure transmitter,and analyze the key purchasing points and usage tips of diffused silicon sensors for you。
Diffused silicon pressure sensors achieve pressure measurement through the piezoresistive effect of semiconductor silicon materials。SY-PG1300-1.6MPa uses a monocrystalline silicon chip as the sensing element,with a piezoresistive coefficient more than 50 times that of ordinary metal strain gauges,and sensitivity up to 2.0mV/V。Compared with models such as PT124B-210-100MPa-NPT1/4,its unique Wheatstone bridge design can control nonlinearity error within ±0.1%FS。
In actual testing,within the operating temperature range of -20℃~+65℃,the zero-point temperature effect of this transmitter is only ±0.02%FS/℃。This stability enables it to maintain reliable output even under extreme operating conditions such as chemical metallurgy,oil and natural gas。It is especially worth noting that its fully welded stainless steel housing structure effectively solves the medium permeation problem commonly seen in HG-S3 pressure transmitters。
We selected mainstream market models for horizontal comparative testing:
Test data shows that SY-PG1300-1.6MPa is clearly superior to the PT-PT300 pressure transmitter in terms of accuracy and stability,while its price is only about 15% lower than FST800-501。The temperature compensation algorithm it uses can automatically correct temperature drift of -0.02~+0.03%FS/℃,which is a technical advantage not available in models such as DG1300-BZ-A-2-1。
1. Installation Specifications:SY-PG1300-1.6MPa uses an NPT1/4 threaded interface,and lateral force should be avoided during installation。For high-pressure models such as HM13-10-250,it is recommended to add a pulse snubber。
2. Medium Compatibility:The housing material of this model is 316L stainless steel,which can measure media such as water and hydraulic oil。However,when measuring corrosive media suitable for the BFY-1103 pressure transmitter,a Hastelloy diaphragm needs to be selected。
3. Electrical Connection:Standard two-wire 4-20mA output,and attention should be paid to the grounding treatment of the shielded cable during wiring。Unlike three-wire models such as DG1300-PJ-1-2-40/CJ/GK/GZ,it does not require a separate power supply wire。
For scenarios requiring miniaturized solutions,you may consider Domestic Load Cell NS-TH17 Miniature Load Cell Load Pressure Button-Type Pressure Sensor,whose 5kg~20t measuring range is especially suitable for installation environments with limited space。
1. Accuracy Class:Industrial-grade models such as PT124B-212-5MPa-ZG1/2 are usually class 0.5,while SY-PG1300-1.6MPa reaches class 0.1,making it suitable for precision control applications。
2. Medium Characteristics:When measuring viscous media,the PT124B series with a flush diaphragm structure should be selected;for gas measurement suitable for DG1300 pressure transmitters,attention should be paid to the minimum operating pressure。
3. Certification Requirements:For hazardous areas,models with ATEX or IECEx certification should be selected,and the SY-PG1300-1.6MPa-GB version has passed GB3836 explosion-proof certification。
1. Regular Calibration:It is recommended to perform zero-point calibration every 6 months and use a standard pressure source to check the linearity of SY-PG1300-1.6MPa。
2. Common Faults:When the output signal is abnormal,the cable insulation resistance(≥5000MΩ)and power supply voltage stability(10VDC±5%)should be checked。
3. Protective Measures:In outdoor scenarios such as water conservancy and electric power,lightning protection modules should be installed for models such as FST800-501。
Overall,with its class 0.1 accuracy,±0.05%/year long-term stability,and 150% safe overload capacity,SY-PG1300-1.6MPa has become a cost-effective choice among diffused silicon pressure transmitters。Whether compared with PT124B-210-100MPa-NPT1/4 in structural strength,or with HM13-10-250 in temperature characteristics,it demonstrates clear technical advantages。
For applications requiring higher integration,Domestic Load Cell NS-TH17 Miniature Load Cell Load Pressure Button-Type Pressure Sensor provides a compact solution。Its alloy steel material and 2.0±0.1mV/V sensitivity make it especially suitable for force measurement scenarios such as electronic scales and truck scales。
If you need detailed technical information or a customized solution for SY-PG1300-1.6MPa,please contact our engineering team for professional support。
Related Recommendations