SMP131-TLD-L105GS-D1-F-53-4G15 Pressure Transmitter Wiring Diagram Explained, 3 Steps to Solve Installation Difficulties
Added to Favorites:125

Is the wiring diagram of the SMP131-TLD-L105GS-D1-F-53-4G15压力 transmitter troubling many operators? This article will break down the installation challenges of diffused silicon liquid and gas pressure sensors in 3 steps, helping you quickly master the wiring essentials and troubleshooting techniques for models such as KYB-800 and HTJ-HTJ110.


I. Core Principles and Definition of Pressure Transmitter Wiring Diagrams


Diffused silicon liquid and gas pressure transmitters (such as models SMP131-TLD-L105GS-D1-F-53-4G15 and KYB-800) convert pressure signals through the piezoresistive effect of silicon crystals. Their wiring diagrams are essentially electrical isolation designs for the sensor, power supply, and signal output in accordance with the IEC 61508 standard, ensuring stable transmission of 4-20mA or 0-10V standard signals. Taking HTJ-HTJ100 as an example, its working principle relies on a Wheatstone bridge structure, and wiring errors may result in accuracy loss (such as dropping from 0.5% to 1.5%) or directly damage sensitive components.


II. 3-Step Standardized Wiring Operation Guide


Step 1: Identify the Interface Type


Compare the interface differences between models such as PT124B-210-1MPa-G1/2 and DG1300-BZ-B-2-10-CJ-AE:


ModelPower InterfaceSignal outputProtection Rating
SMP131-TLD-L105GS-D1-F-53-4G1524VDC±10%Two-wire 4-20mAIP67
KYB-80012-36VDCThree-wire 0-5VIP65

Step 2: Implement Anti-Interference Wiring


According to the requirements of the LD-108-3PBA793 manual, the following must be observed:

  • The distance between signal lines and power lines must be ≥30cm
  • RS485 communication requires twisted pair shielded cable (such as the standard SK-DBS316E1ERC2L-2m cable)
  • Grounding resistance <4Ω (in compliance with the GB/T 15479-2015 standard)

III. Typical Fault Diagnosis and Accuracy Calibration


When HTJ-HTJ110 experiences zero drift, you may follow the NS-I pressure transmitter calibration procedure:

  1. Disconnect the load and measure whether the power supply terminal voltage is within the 18-30VDC range
  2. Apply 50% of full-scale pressure using a standard pressure source, and compare the difference between the displayed value and the standard instrument
  3. Adjust the zero-point parameters through the HART protocol (applicable to intelligent models such as DG1300-BZ-B-2-0.8-CJ-AE)

IV. Why Choose Xi'an Shenghongchuang Instrumentation


As a national high-tech enterprise in Xixian New Area, we provide:

  • The full product range has passed CE/ROHS certification, with an accuracy grade of up to 0.2%FS
  • 72-hour technical response, providing on-site calibration services for models such as HTJ-HTJ100
  • 15 years of industry experience, serving 300+ customers such as PetroChina and Shaangu Power

Get a customized wiring solution for the SMP131-TLD-L105GS-D1-F-53-4G15 pressure transmitter now: 029-8456XXXX | sales@shic-group.com

Submit