News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

PT-A Pressure Transmitter Matching Instrument Selection Guide: Diffused Silicon Sensor Compatibility Test Report
Added to Favorites:125

PT-A Pressure Transmitter Matching Instrument Selection Guide: Diffused Silicon Sensor Compatibility Test Report

In industrial automation control systems, the matching selection of PT-A pressure transmitters and diffused silicon sensors directly affects measurement accuracy and stability. This article conducts systematic compatibility testing for pressure transmitter series such as S-10 and PM-PM320, covering key parameters including wiring methods, measurement range, and service life, providing operators with a selection guide and technical verification report for diffused silicon liquid and gas pressure sensors.


Core Characteristics and Selection Points of Diffused Silicon Sensors

Diffused silicon pressure sensors are well known for their high accuracy and long-term stability, and are particularly suitable for pressure measurement of liquid and gas media. The following parameters should be重点 considered during selection:

  • Measurement Range: For example, the PD-PD50 pressure transmitter is suitable for a 0-100MPa range, and should be selected according to actual working conditions
  • Accuracy Grade: The YSJ-B1 series can reach ±0.1%FS, meeting precision control requirements
  • Media Compatibility: The 316L stainless steel diaphragm can withstand corrosive media
  • Temperature Characteristics: Built-in temperature compensation ensures stability within the -20℃~85℃ range

Test data shows that the combination of the VP-VP451 pressure transmitter and diffused silicon sensor can still maintain 0.2% full-scale accuracy under 60℃ working conditions.


Compatibility Verification of Pressure Transmitters and Sensors

We conducted systematic testing for mainstream models:

Product ModelWiring MethodRange Matching DegreeService Life Test (10,000 cycles)
S-10 Pressure TransmitterFour-wire100%≥50
PM-PM320 Pressure TransmitterTwo-wire95%≥30
CX-203 Pressure TransmitterThree-wire98%≥45

It is particularly worth noting that the PT-A pressure transmitter matching instrument adopts patented sealing technology, and can still maintain the IP67 protection rating under oil-gas mixed working conditions.


Key Technical Points for Installation and Commissioning

The correct installation method directly affects measurement accuracy:

  1. Refer to the PM-PM320 pressure transmitter wiring diagram for standardized wiring to avoid electromagnetic interference
  2. The installation position should avoid vibration sources, and shock-absorbing brackets should be added when necessary
  3. Zero-point calibration is required for first use, and it is recommended to use ZP-801 dedicated accessories
  4. Regularly check the condition of the sealing parts of VP-VP431 matching equipment

In petrochemical industry cases, the annual average failure rate of correctly installed YXP-YXP5000 original sensor assemblies was reduced to 0.3%.


Maintenance and Service Life Extension Strategies

Based on the measured data of the CX-203 pressure transmitter, we recommend:

  • Check zero drift every 6 months
  • In humid environments, check insulation resistance every quarter(≥5000MΩ)
  • Use dedicated cleaning tools to maintain the diaphragm surface
  • Establish preventive maintenance records to document key parameters

After adopting this solution, a certain water treatment plant increased the average service life of sensors from 3 years to 5.8 years.


Industry Application Solutions

According to the characteristics of different industries, we have developed customized solutions:

  • Petrochemical: Explosion-proof VP series + special Teflon isolation diaphragm
  • Power and Energy: High-temperature PD series(resistant to 150℃)
  • Food and Pharmaceutical: Hygienic-grade YSJ-B1 + 3A-certified structure

In the field of flow control, Domestic weighing sensor LCS-H3 high box-type parallel beam tension sensor combined with a pressure transmitter has achieved ±0.05% ultra-high accuracy in oil pipeline flow metering.


Technical Summary and Purchasing Recommendations

Verified through 2000 hours of continuous testing:

  1. The stability of original matching instruments(such as the PT-A series)is 38% better than third-party combinations
  2. Sensors using diffused silicon technology improve response speed by 20ms in dynamic pressure measurement
  3. It is recommended to prioritize models with temperature compensation, such as the VP-VP451 pressure transmitter

As a national high-tech enterprise, Xi'an Shenghongchuang Instrument Co., Ltd. has all products certified by ISO9001 and provides an ultra-long 36-month warranty. If you need to obtain the complete test report or professional technical consultation, please contact our engineering team immediately.