Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
As a key device in industrial measurement,the accuracy of the PT3100-10-I-U pressure transmitter directly affects production safety and efficiency。This article explains the calibration process of diffused silicon sensors in detail,covering calibration essentials for common models such as PT124B-213 and PBLN-C,while also analyzing the operating principles of transmitters such as 2091200PG-H2,helping operators quickly resolve YM-MHQ sensor faults and improve the measurement accuracy of equipment such as MPM489。
Diffused silicon pressure sensors measure pressure through the semiconductor piezoresistive effect,with the core component being a Wheatstone bridge formed by diffusion on a silicon chip。When the pressure of the measured medium acts on the sensitive diaphragm,the bridge resistance changes,outputting an electrical signal proportional to the pressure。Taking the 2091200PG-H2 pressure transmitter as an example,its typical operating voltage is 24VDC,it outputs a 4~20mA standard signal,and its accuracy can reach class 0.25。
Compared with traditional sensors,diffused silicon technology features high sensitivity(up to 2mV/V),good temperature characteristics(≤±0.05%FS/℃),and excellent long-term stability(±0.1%FS/year)。It is especially suitable for applications such as Domestic High-Temperature Pressure Transmitter CYB-10 Diffused Silicon 2088 Pressure Sensor that need to operate across a wide temperature range of -30~+85℃。
Before calibration,prepare a standard pressure source of class 0.05 or higher,a precision ammeter,and a 24VDC regulated power supply:
For threaded installation models such as PT124B-213-2MPa-1/2NPT,special attention should be paid to the sealing performance of the interface,and a torque wrench should be used to tighten to the standard torque of 15N·m during calibration。
When the YM-MHQ pressure transmitter shows abnormal display,it is recommended to troubleshoot according to the following process:
For sensors used in high-temperature conditions such as KGY-KGY50,it is recommended to perform temperature compensation calibration once a year and use a thermostatic bath to test temperature drift within the 0~70℃ range。
Select the appropriate model according to measurement requirements:
In the petrochemical industry,the PAA-21SC-80400.33 model made of 316 stainless steel is recommended,as its corrosion resistance meets the requirements of H2S acidic environments。
To ensure the long-term stability of transmitters such as 501-9000031:
For devices with accuracy class 0.25 such as MPM489(0-40MPa)E22B1C5S,it is recommended to establish calibration records and record the temperature and humidity environmental data for each calibration。
Mastering the calibration technology for diffused silicon pressure transmitters can significantly improve the measurement reliability of equipment such as PT3100-10-I-U。Operators are advised to:
For more application solutions related to diffused silicon sensors,please consult professional technical personnel。High-precision measurement is the foundation for ensuring industrial safety,and proper use and maintenance will keep equipment performance consistently up to standard。