Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
In industrial field pressure measurement, insufficient accuracy often leads to distorted production data. The PT1661 pressure transmitter uses a military-grade sensor core combined with a temperature compensation algorithm to control measurement error within ±0.1%FS, effectively solving the accuracy degradation problems of traditional transmitters caused by temperature drift and media corrosion. This article will provide an in-depth analysis of its technical differences from models such as STZ7 and DY20X, as well as key selection points.
In process industries such as petrochemicals and power energy, a pressure transmitter measurement error exceeding 0.5% may trigger a chain reaction. Taking a catalytic cracking unit in a refinery as an example, the PT1001 pressure transmitter experienced diaphragm deformation due to medium coking, and its accuracy deteriorated from ±0.3% to ±1.2% within three months, directly causing annual output value losses of more than 8 million yuan. The PT1661 pressure transmitter breaks through this bottleneck through three innovations: ① an integrated 316L stainless steel diaphragm structure, with corrosion resistance 3 times higher than DY20X; ② a built-in temperature sensor for real-time data correction, with drift less than 0.02%/℃ under operating conditions of -40℃~125℃; ③ a triple-redundancy calibration mechanism compliant with IEC 60770-1:2010 standards.
In the pressure monitoring system of a natural gas transmission and distribution station, comparative testing between the CFBPK/B pressure transmitter and PT1661 shows that when the ambient temperature drops sharply from 25℃ to -20℃, the former output value drifts by 1.2MPa, while the latter controls the deviation within 0.15MPa through a digital compensation algorithm. This stability is particularly critical in LNG storage tank safety interlock systems—according to the API 670 standard, the trigger pressure tolerance of the emergency shut-off valve must be less than 0.3%. Xi'an Shenghongchuang's HAKK-316 series has also achieved breakthroughs on offshore drilling platforms, with its IP68 protection rating and SIL2 certification perfectly addressing salt spray corrosion and vibration conditions.
As a national high-tech enterprise, we hold 15 invention patents in the field of pressure measurement, and the STZ1-2 pressure transmitter has also won the Science and Technology Progress Award of the China Instrument and Control Society. The production base in Xixian New Area is equipped with the German KROHNE calibration system, ensuring that each PT1661 undergoes a 72-hour aging test before leaving the factory. Our technical team provides full-process support from selection consultation to on-site commissioning, and has delivered 2000+ customized solutions for clients such as Yanchang Petroleum and Shaangu Power. Call 029-84561234 now to obtain an exclusive working condition evaluation report, and the first 20 inquirers can enjoy free technical training slots.
Related Recommendations