News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

How to Identify the Authenticity of Original Genuine PT124B-210-25MPa-R1/4 Pressure Transmitter
Added to Favorites:125

I、Core Factors for Identifying Original Genuine Products


In industrial automation systems,the measurement accuracy of the PT124B-210-25MPa-R1/4 pressure transmitter directly affects the quality of process control。Technical evaluation personnel should focus on the following identification factors:First,check the laser-engraved markings on the product housing。An original genuine product will clearly indicate the model,range(such as 25MPa),interface specification(R1/4)and explosion-proof certification code;Second,verify the production batch through the QR code traceability system provided by the manufacturer。The packaging process of the diffused silicon sensor chip should show no burrs or traces of glue overflow。It is worth noting that,for high-precision instruments such as domestic ultrasonic flowmeter HQTDS-100H clamp-on ultrasonic flowmeter pipeline water flowmeter,their core components also require strict factory inspection reports as supporting evidence。


1.1 Technical Parameter Verification Standards


Genuine PT124B series pressure transmitters must comply with the IEC 60770-1 standard。Key parameters include:zero output signal 4.00±0.02mA(corresponding to 0MPa state),full-scale output 20.00±0.03mA(25MPa state),temperature drift coefficient ≤±0.5%FS/10℃。When comparing with similar products such as M514X-C2484E-250BG,special attention should be paid to media compatibility parameters——the resistance of original diffused silicon sensors to corrosive gases is usually better than that of ordinary silicon diaphragm structures。Technical evaluation personnel can use a standard pressure source for three-point calibration(0%,50%,100% range),and the linearity error of genuine products should be controlled within ±0.1%FS。


II、Manufacturer Qualification Verification System


Regular pressure transmitter manufacturers must hold ISO 9001 quality management system certification,ATEX explosion-proof certification(if used in hazardous areas)and SIL safety integrity level certificates。Taking the DG1300-PJ-1-CJ/GK/GZ model as an example,its technical documentation should include a complete CE certification number and test reports from third-party testing organizations(such as TÜV)。During evaluation,it is necessary to log in to the official website of the certification body to verify the validity of the certificate,with particular attention to whether the product model range covered by the certificate includes the specific procurement batch。


2.1 Supply Chain Traceability Mechanism


Original genuine products usually use a three-level packaging system:anti-static bag(with desiccant),shock-resistant foam inner box,and sealed outer carton printed with the manufacturer LOGO。Each device should have an independent stamped serial number,corresponding one-to-one with the production records and inspection data in the quality traceability system。The technical team may request the supplier to provide purchase certificates for the diffused silicon chips,and verify whether they are original wafers from well-known brands such as Honeywell and Sensata。This is similar to the field of high-precision flowmeters,for example,the ultrasonic transducer of the HQTDS-100H model must provide original acoustic performance test data。


III、Analysis of Typical Counterfeiting Characteristics


Common counterfeiting methods in the market include:using ordinary strain gauges to imitate diffused silicon sensors,tampering with range labels(such as recalibrating a 10MPa product as 25MPa),copying housing molds of other brands,etc。During technical evaluation,attention should be paid to the following:the pressure connection of genuine PT124B is integrally machined from 316L stainless steel,while imitation products often show welding marks;the surface-mounted components on the original circuit board are arranged neatly,the solder joints are full and glossy,and key chips(such as ADuC847)have laser-etched batch codes on their surfaces。


3.1 Performance Comparison Test Method


It is recommended to build a standard test platform for comparative verification:in an environment of 25℃±1℃,use a Fluke 725 pressure calibrator to apply step pressure(0MPa→5MPa→10MPa→15MPa→20MPa→25MPa),and record the output signal at each point。The hysteresis error of a genuine transmitter should be ≤0.05%FS,while imitation products usually exceed 0.2%FS。At the same time,conduct a 48-hour continuous pressure test。The zero drift value of a genuine product should be <0.1%FS,which is equivalent to the stability requirements of micro-pressure transmitters such as MPM489(0-6mH2O)E22B2C1G。


IV、Industry Procurement Recommendations


For pressure monitoring at critical process points,it is recommended to give priority to manufacturers that provide complete technical support。High-quality suppliers are equipped with professional technical service teams,and can recommend suitable sealing materials and diaphragm materials according to specific media characteristics(such as corrosive gases,high-temperature liquids,etc)。At the same time,attention should be paid to product maintainability——original genuine products usually adopt modular design,for example,the sensor module and signal processing board of the PS6000-BZ-A1-A-40/CD10/D model can be quickly replaced,greatly reducing later maintenance costs。


4.1 Key Points for Alternative Solution Evaluation


When the budget is limited,the technical team may consider high-quality domestic brands with comparable performance,but should focus on verifying:whether original imported diffused silicon chips are used(such as products from Germany's First Sensor),whether certification from the National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation(NEPSI)has been obtained,and whether a 5-year warranty commitment equivalent to DMP331-130-4003-1-9-999 is provided。When evaluating alternative solutions,it is recommended to refer to the selection logic of similar products such as domestic ultrasonic flowmeter HQTDS-100H,that is,core parameters(such as accuracy and stability)must meet the standards,while non-critical features(such as housing material)can be appropriately compromised。


V、Professional Technical Support Services


We provide pressure transmitter users with a three-level technical support system:1)free calibration reports compliant with ISO 17025 standards;2)on-site installation guidance services(including special mounting bracket configuration solutions for the BP-H model);3)lifetime free technical consultation。For complex operating conditions such as CR-YM2,our engineers can assist in designing overall solutions for vibration resistance and electromagnetic interference resistance。All products come with dedicated debugging software,which can monitor the temperature compensation curves and operating status records of models such as MPM489E22B1C2G in real time。

Submit