News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

PQ50-GB10CG12M4B Pressure Transmitter Operation Guide: 5-Step Quick Installation Method for Diffused Silicon Sensor
Added to Favorites:125

Introduction

As a professional supplier in the field of flow control equipment, Xi'an Shenghongchuang Instrumentation Co., Ltd. brings you a 5-step quick installation guide for the PQ50-GB10CG12M4B pressure transmitter diffused silicon sensor. This operation manual will introduce in detail this liquid and gas pressure sensor using original genuine diffused silicon technology, helping contract executors quickly master the installation essentials of supporting equipment such as KYB11G01M1PXC1-I, and ensuring the precise matched use of the MSZ-MSZ11 pressure transmitter with models such as EDYBT-4.


Product Overview of PQ50-GB10CG12M4B Pressure Transmitter

The PQ50-GB10CG12M4B pressure transmitter adopts advanced diffused silicon sensing technology and is specially designed for liquid and gas pressure measurement. This product features high accuracy of 0.1%FS, a working temperature range of -40℃~125℃, and a protection rating of IP67, enabling it to adapt to various harsh industrial environments. Its core component uses the TY-TY211 original genuine diffused silicon sensor chip to ensure long-term stability and measurement accuracy.

This model can be seamlessly connected with the MSWD-MSWD11 display instrument and outputs a standard 4-20mA signal. The product has passed CE certification and complies with the GB/T 17614.3-2013 national standard, making it particularly suitable for process control systems in industries such as petrochemicals and power energy.


Detailed Explanation of the 5-Step Quick Installation Method

Step 1: Preparation Before Installation

1. Check the integrity of the packaging and confirm that the received pressure transmitter is the original 2200BGH-UA genuine product
2. Prepare the matching MS-MS501 mounting bracket and sealing gasket
3. Ensure that the installation environment meets the technical specification requirements of AST-L0250
4. Prepare a dedicated installation tool kit (torque wrench, sealant, etc.)

Step 2: Mechanical Installation

1. Use the dedicated KYB11G01M1PXC1-I installation fixture to secure the transmitter body
2. Connect the process interface according to the thread specification (usually G1/2 or NPT1/2)
3. Apply an installation torque of 25-30N·m to avoid sensor damage caused by over-tightening
4. Check the airtightness of all connection points

Step 3: Electrical Connection

1. Refer to the wiring diagram of the matching MSZ-MSZ11 instrument for connection
2. Use shielded cable (recommended cross-sectional area ≥0.75mm²)
3. Pay attention to the power supply polarity (usually the brown wire connects to the positive terminal and the blue wire connects to the negative terminal)
4. Ensure proper grounding treatment, and the grounding resistance should be less than 4Ω

Step 4: Parameter Setting

1. Connect the configuration software through the EDYBT-4 communication interface
2. Set the measuring range (default 0-10MPa adjustable)
3. Calibrate the zero point (under normal atmospheric pressure)
4. Set the output signal damping time (usually adjustable from 0.1-10s)

Step 5: Functional Verification

1. Gradually apply pressure to test the calibrated accuracy indicators of HB-31C
2. Check the linearity error over the full range (should be ≤±0.2%FS)
3. Conduct a 24-hour stability test
4. Record the initial performance parameters as baseline data


Common Problem Solutions

Problem SymptomsPossible CauseSolutions
Unstable output signal2. 机械振动
3. 密封失效>1. Power supply interference
2. Mechanical vibration
3. Seal failure
2. 加装减震装置
3. 更换密封件>1. Check the power filter
2. Install vibration damping devices
3. Replace the seal
Zero drift2. 过载损坏
3. 老化>1. Temperature effect
2. Overload damage
3. Aging
2. 检查是否超压
3. 联系厂家校准>1. Perform temperature compensation
2. Check whether there is overpressure
3. Contact the manufacturer for calibration
Communication fault2. 协议不匹配
3. 硬件损坏>1. Wiring error
2. Protocol mismatch
3. Hardware damage
2. 确认通信协议
3. 返厂检测>1. Check the wiring
2. Confirm the communication protocol
3. Return to the factory for inspection

Maintenance Recommendations

To ensure that the PQ50-GB10CG12M4B pressure transmitter reaches its design service life (usually 8-10 years), it is recommended to:

  1. Perform an accuracy calibration every 6 months
  2. Replace the sealing components once a year
  3. Avoid medium crystallization or solidification on the sensor diaphragm
  4. Regularly check the integrity of the cable protective sleeve
  5. Establish complete equipment maintenance records

Summary and Technical Support

This guide details the standardized installation process of the PQ50-GB10CG12M4B diffused silicon pressure transmitter. As a professional sensor manufacturer, Xi'an Shenghongchuang Instrumentation Co., Ltd. has all products certified under the ISO9001 quality management system and provides a 36-month quality warranty. If you need to learn more technical details about the MSWD-MSWD11 matching instrument or the EDYBT-4 communication module, our engineering team is always ready to provide you with professional support.

Contact our technical consultants now:
Tel: 029-8888XXXX
Email: service@shic-tech.com
Website: www.shic-tech.com

Submit