News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

PH-PH210 Pressure Transmitter Price Revealed: A Must-Read Guide to Diffused Silicon Sensor Procurement
Added to Favorites:125

Analysis of Core Purchasing Indicators for Diffused Silicon Pressure Transmitters


As key equipment in the field of industrial automation, the price and performance of the PH-PH210 pressure transmitter directly affect project costs and operational stability. This article provides an in-depth analysis of the procurement priorities for diffused silicon sensors, covering calibration methods, specification parameters, and troubleshooting solutions for mainstream models such as OT-1 and OC-1, helping contract executors accurately control the entire procurement process.


In industrial process control systems, the price range of diffused silicon pressure transmitters is usually influenced by three major factors: sensor accuracy, material grade, and measurement range. Taking the PH-PH210 model as an example, it adopts the piezoresistive effect principle of single-crystal silicon, with measurement accuracy up to ±0.1%FS. Its stainless steel 316L diaphragm structure enables it to maintain stable output even in corrosive media, and the market quotation for this type of high-performance configuration usually fluctuates within the range of 2000-4500 yuan.


Comparison of Technical Parameters of Mainstream Models


ModelMeasuring RangeOutput SignalAccuracy ClassReference price(yuan)
PH-PH2100-10MPa4-20mA/RS485Class 0.13200-4500
OT-10-2.5MPa0-10VClass 0.251800-2600
OC-10-60MPa4-20mA/HARTClass 0.23800-5500

Calibration Procedures and Fault Diagnosis


For the calibration of diffused silicon sensors such as the OC-1 pressure transmitter, the IEC 60770 standard process must be followed: first apply pressure at 25%, 50%, 75%, and 100% range points through a standard pressure source, while recording the output current values. If the nonlinearity error exceeds ±0.2%, zero shift and full-scale adjustment are required. Common faults, such as display abnormalities in the DLT-DLT200 model, are mostly caused by power fluctuations or diaphragm damage. These can be checked by using a multimeter to test the supply voltage (normal range 18-30VDC) or by using the Domestic displacement sensor LVDT-800MM differential drawbar linear displacement sensor spring-return inductive sensor to assist in checking the mechanical connection status.


Key Factors in Selection Decision-Making


When evaluating models such as CHSP-210 and PM-PM200, contract executors should focus on the following dimensions:


  • Media compatibility: Fluororubber seals are suitable for most oil-based media, while PTFE material can handle strong acid and alkali working conditions
  • Environmental adaptability: The IP67 protection rating of the SPB-SPB101 model can meet outdoor dustproof and waterproof requirements
  • Signal matching: The 0-5V output of the A-10 pressure transmitter is better suited to PLC analog input modules
  • Certification requirements: For explosive environments, choose the FDS-S series with ATEX or SIL certification

In-Depth Interpretation of Technical Documentation


Key parameters in the 501 pressure transmitter manual are often overlooked: preheating time directly affects initial measurement accuracy, and high-quality diffused silicon sensors can usually achieve nominal accuracy after being powered on for 5 minutes. Important hidden information in the specification model table includes:


  1. Temperature compensation range (-20℃~120℃ is the industrial standard)
  2. Long-term stability indicator (annual drift <0.1%FS is considered qualified)
  3. Vibration impact (output change <0.05% under 2g vibration)

Procurement Strategies and Cost Optimization


When purchasing PH-PH210 pressure transmitters in bulk, it is recommended to adopt a tiered quotation strategy: orders of 50 units or more can strive for a price discount of 8%-12%. At the same time, attention should be paid to:


  • Include calibration services in the contract terms and require the supplier to provide third-party test reports
  • Reserve 5%-10% of the spare parts budget to deal with unexpected failures
  • Require the provision of a complete specification model list (including derivative models such as DLT-DLT200) for subsequent expansion

Recommended Industry Solutions


For compound working conditions requiring simultaneous monitoring of displacement and pressure, the PH-PH210 transmitter can be used in combination with the Domestic displacement sensor LVDT-800MM differential drawbar linear displacement sensor spring-return inductive sensor. This solution is particularly suitable for scenarios such as synchronous control of hydraulic cylinders and monitoring of compressor piston stroke. The μ-level resolution of the differential transformer type displacement sensor and the rapid response of the pressure transmitter can form complementary advantages.


Summary and Professional Recommendations


When selecting a diffused silicon pressure transmitter, contract executors should establish a multidimensional evaluation system: from the cost-performance trade-off of the OT-1 basic model, to the calibration complexity of the OC-1 high-pressure model, and then to the stability verification of the SPB-SPB101 high-precision model, every link directly affects the total life-cycle cost of the project. As a national high-tech enterprise, Xi'an Shenghongchuang Instrumentation Co., Ltd. can provide a full range of pressure measurement solutions including the PH-PH210, and supports customized calibration and fault diagnosis services.


Contact our technical team now to obtain an exclusive model selection report and the optimal quotation plan, and our professional technical engineers will provide you with full-process support from specification confirmation to installation and commissioning.

Submit