Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
Is the unstable remote transmission signal of the PA1000 pressure transmitter troubling many users? As a key device for diffused silicon liquid and gas pressure sensors, signal abnormalities may affect the entire control system. This article focuses on the remote transmission signal issues of the PA-PA1000 pressure transmitter, analyzes 5 common causes of failure, and provides professional solutions to help operators quickly troubleshoot problems and ensure stable equipment operation.
When the supply voltage of the PA-PA1000 pressure transmitter exceeds the 9~36VDC range, the remote transmission signal will show obvious fluctuations. Especially in two-wire connection scenarios, insufficient voltage will cause distortion in the 4~20mA signal output.
In strong electromagnetic environments such as petrochemical plants and power stations, unshielded cables can cause interference to the signals of diffused silicon liquid and gas pressure sensors. Test data shows that without shielding measures, signal noise can reach 5%-8% of the full scale range.
When the temperature of the measured medium exceeds the technical parameter range of -30~+85℃, the temperature drift of diffused silicon sensors such as KL-KL316 will increase significantly (up to ±0.1%FS/℃), causing drift in the remote transmission signal.
In vibration environments such as air compressors and locomotive braking systems, micron-level displacement may occur at the M20×1.5 threaded connection. Experiments show that this can cause contact resistance changes of up to 10-15Ω, directly affecting the stability of signal transmission.
It is recommended to use the DT-131 pressure transmitter mounting bracket with an anti-loosening design, or apply Loctite 243 threadlocker to the connection parts.
According to the ISO9001 standard, industrial-grade pressure transmitters such as DBS-DBS316 should be calibrated once every 6 months. After long-term operation, stress relaxation of the sensor diaphragm will lead to zero-point drift (typical value ±0.2%FS/year).
For level measurement and control scenarios requiring high stability, it is recommended to select the PT124B-211 pressure transmitter with digital display function. Its 0.25 accuracy class and ≤5ms response time can effectively avoid signal delay issues. This product uses 316 stainless steel for medium-contact materials, making it particularly suitable for corrosive medium environments.
The unstable signal problem of the PA1000 pressure transmitter is mostly caused by five major factors: power supply, interference, temperature, vibration, and calibration. Through the solutions provided in this article, the normal operation of equipment such as the XL-802A model can be quickly restored. If you need the YB-YB3101 installation instructions or customized solutions, please contact the professional technical team of Xi'an Shenghongchuang Instrumentation Co., Ltd.
Related Recommendations