P200S-GB160CG14M4B Pressure Transmitter Specifications Explained in Detail, These 5 Parameters Are Essential for Selection!
Added to Favorites:125

As a core component of industrial flow control, the selection of the P200S-GB160CG14M4B pressure transmitter directly affects system accuracy and stability. This article focuses on the 5 key parameters of greatest concern to technical evaluators, providing a detailed analysis of the specification characteristics of this diffused silicon liquid and gas pressure sensor to help you quickly match application requirements. As a professional sensor manufacturer, Xi'an Shenghongchuang Instrumentation covers multiple fields including pressure, displacement, and flow, and provides a one-year warranty service.


I. Analysis of Technical Performance and Core Parameters


In the field of industrial automation, the accuracy grade of a pressure transmitter directly determines the quality of system control. The P200S-GB160CG14M4B adopts imported diffused silicon sensing elements, and its 0.1%FS high-accuracy index is far above the industry average. Comparative tests have found that within the 0~160bar range, the temperature drift coefficient of this model can be controlled within ±0.01%/℃, making it particularly suitable for application scenarios with large temperature differences such as oil and gas pipelines.


As one of the key parameters, this model provides a dual-interface configuration of 4-20mA analog output and RS485 digital communication. Measured data show that its electromagnetic interference resistance reaches the EN 61000-6-2 standard, and it can still maintain stable signals in industrial sites dense with frequency converters. Special attention should be paid during technical evaluation: when the medium temperature exceeds 125℃, a high-temperature heat dissipation module should be selected to ensure long-term stability.


Parameter CategoryTechnical MetricsTest Standard
Measuring Range0-160barGB/T 1226
Overall Accuracy±0.1%FSJJG 882
Long-Term Stability≤±0.2%/yearIEC 60770
Medium Temperature-40~125℃EN 60770
Protection RatingIP67IEC 60529

II. Selection Matching and Application Condition Adaptation Guide


For different medium characteristics, the P200S-GB160CG14M4B provides two diaphragm options: 316L stainless steel and Hastelloy. In highly corrosive scenarios such as chlor-alkali chemical industries, the version using a C276 alloy diaphragm can extend service life by more than 3 times. Our engineering cases show that in the hydrochloric acid metering system of a chemical plant in Shaanxi, this model has operated continuously and stably for more than 26 months.


The choice of installation method also affects measurement accuracy. When used for gas pressure detection, it is recommended to use vertical installation with the pressure port facing downward; for liquid measurement, it is recommended that the process connection be located on the side of the pipeline. Tests by the technical team found that incorrect installation posture can lead to an additional error of up to 0.5%. For occasions with relatively large vibration, the standard M20×1.5 threaded installation combined with a vibration-damping bracket works best.


III. Industry Applications and Analysis of Typical Scenarios


In the oil and natural gas field, this model has been successfully applied to the flow control system of a booster station in the West-to-East Gas Pipeline project. Its unique temperature compensation algorithm effectively overcomes the challenge of large day-night temperature differences in Xinjiang, keeping the pressure measurement fluctuation of the station control system within ±0.05%. Compared with similar PTX-PTX5072 pressure transmitters, its response speed is increased by 40%, making it especially suitable for transient pressure monitoring.


The water treatment industry pays more attention to anti-clogging design. The flat diaphragm structure of the P200S-GB160CG14M4B combined with self-cleaning electrodes performs excellently in pressure monitoring of aeration tanks in wastewater treatment plants. Comparative tests with the DJ-DJ1300 pressure transmitter show that in media containing solid particles, its maintenance cycle is extended to 18 months, greatly reducing downtime costs.


IV. Common Technical Issues and Solutions


Q1: How to determine whether remote transmission function is needed? When the signal transmission distance exceeds 50 meters or there is strong electromagnetic interference, the HART protocol remote transmission module equipped on the HT-316 pressure transmitter can effectively solve signal attenuation problems. In the solution we designed for a power plant in Shaanxi, stable transmission over a distance of 300 meters was achieved by adding a signal repeater.


Q2: How is the alarm control function configured? This model can optionally be equipped with dual relay outputs, and users can set alarm thresholds through the configuration software paired with the CL-H pressure transmitter. Practical applications show that in air compressor group control systems, this early warning mechanism can reduce 80% of accidental shutdown incidents.


V. Professional Technical Support and Service Commitment


As a leading sensor manufacturer in Northwest China, Xi'an Shenghongchuang Instrumentation provides full-process services from selection consultation to installation and commissioning. All P200S-GB160CG14M4B pressure transmitters leaving the factory undergo 72-hour aging tests and are accompanied by CNAS-certified inspection reports. Our engineering team has assisted in completing an intelligent upgrade project for more than 200 measuring points at a PetroChina refinery and has extensive hands-on experience.


For the special needs of technical evaluators, we provide: ① free sample testing service; ② customized parameter configuration; ③ on-site technical training. All products enjoy a 12-month warranty, and key components are provided with lifetime maintenance. Click on the official website for online consultation to obtain the latest version of the YM2200-M1410V160B pressure transmitter installation guide manual.