Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
As a key sensor in the field of industrial automation,the P200S-GB160CG14M4B pressure transmitter uses diffused silicon technology to accurately measure liquid and gas pressure。This article will comprehensively analyze the specifications,installation methods,and selection key points of this model,helping operators quickly master the technical characteristics of similar products such as DG1300-PJ-1-2-10/AAZN and KE-240X-250BG5B,and solve selection challenges in practical applications。
The P200S-GB160CG14M4B adopts diffused silicon sensing technology,offering excellent media compatibility and long-term stability。Its core parameters include:
Particularly noteworthy are its G1/4" process connection and 316L stainless steel diaphragm design。Compared with the PTX-PTX5072 model,it is more suitable for measuring corrosive media。Its zero-point temperature effect is only ±0.02%/10K,better than the general industry level。
The diffused silicon technology used in models such as KE-240X-250BG5B forms a Wheatstone bridge by diffusion on a silicon wafer。When pressure is applied,the silicon diaphragm deforms,causing resistance changes,and a standard signal is output through the signal conditioning circuit。The P200S-GB160CG14M4B innovatively adopts a temperature compensation algorithm,allowing it to maintain temperature drift accuracy of ±0.1% within the operating range of -20℃~+65℃(comparable to the temperature adaptation range of the domestic load cell BLR-SQE tension and compression S-type stainless steel load cell)。
Compared with traditional products such as MBC-STK333,its advantages include:
For common installation issues of models such as YM2200-M1410V160B and DJ-DJ1300,the P200S-GB160CG14M4B provides the following solutions:
• Use a 17mm open-end wrench to tighten the process connection,do not apply force to the housing
• In vibration applications,a shock-absorbing bracket should be installed,and the location should avoid pipe bends
• Vertical installation is recommended when measuring gases,and the pressure port should be kept facing downward when measuring liquids
• Use shielded twisted-pair cable(cross-sectional area ≥0.5mm²)
• Grounding resistance <4Ω,avoid sharing a power supply with frequency converters
• Explosion-proof applications must comply with GB3836.1-2010 standard
In the petrochemical field,the P200S-GB160CG14M4B has successfully replaced the DG1300-PJ-1-2-10/AAZN model,with advantages including:
Daily maintenance requires attention to the following:check the condition of seals every 6 months;when the medium crystallizes,a diaphragm flushing port should be selected;keep the storage environment dry(relative humidity <60%)。Similar to the domestic load cell BLR-SQE tension and compression S-type stainless steel load cell,regular calibration can ensure measurement accuracy。
With its outstanding specifications and stable performance,the P200S-GB160CG14M4B has become a benchmark product in the field of diffused silicon pressure transmitters。Whether compared with KE-240X-250BG5B in technical performance or with PTX-PTX5072 in dimensional adaptability,it demonstrates clear advantages。
If you need complete dimensional drawings,installation videos,or customized solutions,please contact our technical team。We provide full-process services from selection guidance to on-site commissioning,ensuring that your pressure measurement system always remains in optimal condition。
Consult Now:Professional technical engineers will provide you with comparative analysis reports for the full range of products such as DG1300-PJ-1-2-10/AAZN and YM2200-M1410V160B。
Related Recommendations