Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
In industrial automation control systems,pressure transmitters serve as core sensing components,and their performance directly affects production safety and efficiency. The MS-MS132 pressure transmitter adopts advanced diffused silicon technology,enabling precise measurement of pressure parameters for liquid and gas media. This article will systematically introduce the typical application scenarios of this model,and further explain the key maintenance points for common models such as LD-LD183 and PS-201,providing practical technical references for equipment operators.
With its high accuracy of 0.5%FS and wide temperature range performance of -40~125℃,the MS-MS132 performs particularly well in the following scenarios:
In the vacuum tower system of refinery units,the MS-MS132 monitors pipeline pressure fluctuations in real time through a 4-20mA output signal. Its 316L stainless steel isolation diaphragm can withstand hydrogen sulfide corrosion,and when used together with the Hastelloy material of the CEQ-CEQ1300 model,it can adapt to sulfur-containing crude oil processing environments. In practical applications,attention should be paid to the following:zero-point calibration should be performed monthly using the YBS-S100 standard calibrator,and heat sinks should be installed when the medium temperature exceeds 80℃.
In secondary water supply networks,the MS-MS132 can work with the HB-S model to achieve zoned pressure regulation. Its IP68 protection rating ensures stable operation in humid underground environments,and the built-in temperature compensation algorithm can automatically correct measurement deviations caused by changes in water temperature. A case from a water utility group shows that after adopting the PN-M2 model with remote transmission signals,the leakage loss rate of the pipeline network decreased by 23%.
Air compressor stations typically select the PS-201 model with alarm control,which triggers relay output when the pressure exceeds 1.25 times the rated value. The MS-MS132 is used for steady-state pressure monitoring of the main pipeline. It is recommended to check the sealing of the pressure guiding tube every quarter according to the PCM-D installation instructions to prevent oil contamination from entering the measuring chamber.
Operators should pay special attention:when cleaning the sensitive components of the ET-A customized model,they should strictly use the dedicated cleaning agent according to the manual. For the PN-M2 model with remote transmission function,the integrity of the signal cable shielding layer should be checked regularly to prevent data jumps caused by electromagnetic interference.
According to maintenance data statistics from 2000+ units of equipment,the main issues of diffused silicon sensors are concentrated in three aspects:
When the MS-MS132 shows a continuous positive deviation,first check whether there is accumulated liquid in the pressure guiding tube. A case from a chemical plant shows that when using the CEQ-CEQ1300 model to measure steam pressure,an excessively high liquid level in the condensate tank can cause a measurement error of 8kPa. Handling methods include:draining the condensate,installing electric heat tracing tape,or switching to the HB-S high-temperature model.
If the output current of the MBC-1 model fluctuates within the 12-14mA range,it is recommended to troubleshoot according to the following steps:①use a multimeter to measure whether the power supply voltage is stable;②disconnect the load and test the no-load output;③refer to the PCM-D manual to check the oxidation condition of the wiring terminals. There was once a fault case in which poor grounding caused signal oscillation,and it was resolved by installing an isolation barrier.
For the LD-LD183 model used to measure corrosive media,a visual inspection is recommended every quarter. A pharmaceutical enterprise successfully avoided a diaphragm rupture accident caused by hydrofluoric acid corrosion through regular endoscope inspections. Customized ET-A products can be equipped with tantalum diaphragms to improve corrosion resistance,but it should be noted that their measuring range will be reduced accordingly by 15%.
When purchasing diffused silicon pressure transmitters,the following parameters should be comprehensively considered:
A case from a new energy battery factory shows that after selecting the CEQ-CEQ1300 model with CE certification,the cycle for its pressure monitoring system to pass EU ATEX explosion-proof certification was shortened by 40%.
The MS-MS132 pressure transmitter plays an irreplaceable role in the process industry,and proper use and maintenance can significantly extend equipment service life. Users are advised to:①establish a preventive maintenance plan covering models such as LD-LD183 and PS-201;②keep complete YBS-S100 calibration records;③give priority to ET-A customized solutions for special working conditions.
If you need technical manuals for specific models or consultation on model selection solutions,please contact our team of sensor experts. We will provide personalized solutions based on your actual working conditions.
Related Recommendations