Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
As a key piece of industrial automation equipment, the accuracy of the M5256-000002-010BG pressure transmitter directly affects production safety and efficiency. This article provides an in-depth analysis of the 5 core performance indicators of diffused silicon liquid and gas pressure sensors for corporate procurement decision-makers, helping you accurately select genuine original-factory products and avoid technical risks.
In the field of flow control equipment, the core advantage of the M5256-000002-010BG pressure transmitter lies in its use of diffused silicon sensing technology, with an accuracy class of up to ±0.1%FS, far superior to traditional strain gauge sensors. This model is certified by Germany's PTB and has a working temperature range of -40℃~125℃, making it particularly suitable for harsh operating conditions such as petrochemicals and electric power energy. Compared with similar products such as DG1300-BZ-A-2-16, its unique temperature compensation algorithm can reduce drift error by 60%, ensuring long-term stability.
During corporate procurement, two indicators need special attention: first, the basic accuracy (usually marked as ±%FS), and M5256-000002-010BG maintains Class 0.1 accuracy at full scale; second, the non-linearity error (tested by the End Point method). Our laboratory test data show that this model has a non-linearity error of ≤±0.05% within the 0-10MPa range, outperforming competing products such as KE-240X-250BG5B. It should be specifically noted that actual accuracy is affected by the medium characteristics; for corrosive fluids, it is recommended to use it with the dedicated 2091Z-H2 isolation diaphragm.
According to the requirements of the ISO 9001:2015 quality management system, we conducted a 12-month aging test on the M5256 series, with annual drift controlled within ±0.2%. In terms of temperature coefficient, within the range of -20℃~80℃, the output deviation caused by each degree Celsius change is <±0.015%/℃. If your application scenario involves severe temperature fluctuations (such as LABO-RT-INS operating conditions), it is recommended to select the version equipped with dual PT100 temperature compensation.
In the field of natural gas transmission, the monitoring system composed of the M5256-000002-010BG and the matching 691-9300271 equipment can achieve millisecond-level response to pipeline pressure. After a provincial pipeline network project adopted this solution, leak detection accuracy increased to 99.7%. In the pharmaceutical industry, the DG1300-PJ-1-2-10/AAXN model, by virtue of its FDA-certified materials, has become the preferred choice for aseptic filling lines. We recommend that customers select diaphragm materials according to specific medium characteristics (such as viscosity and corrosiveness); for hydrogen energy applications, special attention should be paid to the hydrogen embrittlement protection performance of model 506.932A-A03101.
As a national high-tech enterprise in Xixian New Area, we have a CNAS-certified laboratory and 12 patented pressure sensor technologies. All ex-factory products undergo a 72-hour aging test and come with an ultra-long 3-year warranty. For urgent needs, we can provide 48-hour expedited delivery service for the DG1300 series. Contact our engineering team now to obtain customized solutions and on-site installation guidance for the M5256-000002-010BG pressure transmitter.
Related Recommendations