Introduction


Is the LD-108-3PBA793 pressure transmitter manual obscure and difficult to understand? This article focuses on core issues such as the installation, calibration, and troubleshooting of diffused silicon liquid and gas pressure sensors, helping you quickly grasp the operating essentials in 3 minutes. Xi'an Shenghongchuang Instrumentation Co., Ltd. provides you with a detailed explanation of the instrument's working principle and accuracy class, making industrial on-site commissioning more efficient.


I. Analysis of the Core Functions of the Pressure Transmitter


As the "nerve ending" of industrial automation systems, the LD-108-3PBA793 pressure transmitter adopts the diffused silicon piezoresistive principle to convert liquid or gas pressure signals into 4-20mA standard electrical signals. Its core advantages are reflected in the high accuracy of 0.1%FS and the wide-temperature operating capability of -40~85℃, making it particularly suitable for harsh environments such as petrochemical and power energy industries. The engineering team at Xi'an Shenghongchuang Instrumentation Co., Ltd. has found that 90% of on-site faults stem from users' insufficient understanding of basic parameters such as range selection and media compatibility.


II. Breakdown of Key Operating Steps


1. Installation Specifications


• Threaded connection treatment: The G1/2" thread must be sealed with PTFE thread seal tape, and the recommended torque should be controlled within the range of 15-20N·m
• Electrical connection: Use double-shielded cables, and strictly distinguish the signal wires (red/black) from the power wires (blue/brown), with grounding resistance ≤4Ω
• Media flow direction: The direction indicated by the arrow mark on the housing should be consistent with the flow direction of the pipeline medium, and during vertical installation, the process connection fitting must face downward


2. Quick Calibration Method


Standard pressure value(MPa)Theoretical output(mA)Allowable Deviation
0.004.00±0.02mA
0.5012.00±0.03mA
1.0020.00±0.02mA

III. Guide to Typical Fault Handling


When output signal fluctuation occurs, it is recommended to troubleshoot according to the following process:

  1. Check power supply stability (24VDC±10%)
  2. Use a multimeter to measure loop impedance (normal 250-600Ω)
  3. Isolate and test the sensor body's performance
  4. Check whether there is crystallization blockage in the process connection fitting
For zero drift issues occurring in similar products such as HTJ-HTJ110, on-site calibration can be performed by pressing the ZERO key on the housing with a magnetic pen.


IV. Technical Q&A on Model Selection


Q: How to determine whether to choose PT124B-210 or the DG1300 series?
A: Mainly consider three dimensions:
• Process pressure range (the former 0-1MPa, the latter 0-10MPa)
• Medium corrosiveness (DG1300 comes standard with a 316L diaphragm)
• Explosion-proof requirements (PT124B has passed ATEX certification)

Q: How is the IP68 protection of SK-DBS316E1ERC2L-2m tested?
A: It should be carried out according to the IEC60529 standard:
1. Immerse in 1 meter deep water for 30 minutes
2. Air pressure sealing test at 100kPa
3. Insulation resistance ≥100MΩ (500VDC)


V. Professional Technical Support


Xi'an Shenghongchuang Instrumentation Co., Ltd. provides:

  • Free technical model selection consulting services
  • On-site commissioning guidance video package
  • 18-month extended warranty period
  • 48-hour emergency response service
Our engineering team holds ASME B40.9 certification and can customize special working condition solutions for the full series of pressure transmitters from NS-I to KYB-800. Call 029-8456XXXX now for exclusive technical support.

Submit