LDN-LDN210 Pressure Transmitter Dimensional Drawing Download: 5 Space Clearance Recommendations You Must Read Before Installation
Added to Favorites:125

Before installing the LDN-LDN210 pressure transmitter, proper space reservation is critically important. This article provides 5 professional recommendations to help you correctly reserve installation space and ensure stable equipment performance. As an expert in the field of diffused silicon liquid and gas pressure sensors, Xi'an Shenghongchuang Instrumentation Co., Ltd. will provide you with a detailed explanation of the LDN-LDN210 dimensional drawing download and installation key points to help you efficiently complete project execution.


I. Space Reservation Recommendations for the LDN-LDN210 Pressure Transmitter


In industrial automation control systems, the reserved installation space for a pressure transmitter is directly related to the normal operation of the equipment and the convenience of maintenance. The following are 5 key space reservation recommendations applicable to the installation of the LDN-LDN210 pressure transmitter:


  • 1. Ensure sufficient operating space:The LDN-LDN210 pressure transmitter requires at least 50cm of operating space to facilitate installation, commissioning, and maintenance by technical personnel.
  • 2. Consider the junction box position:Additional space is required for the electrical connection part of the transmitter, and it is recommended to reserve a 15-20cm area for the junction box.
  • 3. Leave disassembly space:To facilitate later maintenance, disassembly space equivalent to 1.5 times the length of the equipment should be reserved around the transmitter.
  • 4. Avoid dense installation:Maintain a distance of at least 30cm from adjacent equipment to prevent heat accumulation from affecting measurement accuracy.
  • 5. Consider pipeline vibration:In environments with significant vibration, additional space should be reserved for vibration damping devices.

II. Technical Performance Analysis of Diffused Silicon Pressure Sensors


The LDN-LDN210 adopts advanced diffused silicon sensing technology and delivers excellent performance. Compared with traditional strain gauge sensors, diffused silicon sensors have higher sensitivity and lower temperature drift. Its core advantages are reflected in:


Performance ParametersLDN-LDN210Conventional strain gauge sensor
Measurement Accuracy±0.25%FS±0.5%FS
Temperature Effect±0.05%FS/℃±0.1%FS/℃
Long-Term Stability±0.1%FS/year±0.3%FS/year
Response Time≤5ms≤20ms

As a professional high-tech enterprise, Xi'an Shenghongchuang Instrumentation Co., Ltd. ensures that every LDN series pressure transmitter it manufactures meets industry standards through strict factory testing.


III. Common Installation Misunderstandings and FAQ for Pressure Transmitters


During actual project execution, contract executors often encounter the following issues:


  1. Misunderstanding 1: Ignoring the influence of medium temperature - Although the LDN-LDN210 can operate at a medium temperature of -30~+85℃, it is recommended to additionally consider heat dissipation space in high-temperature environments.
  2. Misunderstanding 2: Installing directly near the vibration source - Even if the transmitter itself has a vibration-resistant design, it should still avoid being installed directly near pumps or compressors.
  3. FAQ: How to confirm the installation orientation? - During vertical installation, the electrical junction box should face downward to prevent condensate accumulation.
  4. FAQ: What should be noted for threaded connections? - Use appropriate sealing materials and do not overtighten, so as not to damage the sensor diaphragm.

IV. Pressure Transmitter Selection and Alternative Solutions


For special operating condition requirements, such as high-temperature and high-pressure environments, you may consider domestic general-purpose pressure transmitter SPB101 high-temperature absolute pressure sensor, which is made of 316 stainless steel and has a measurement range of up to 0~250MPa, making it particularly suitable for harsh operating conditions in industries such as petrochemicals and electric power.


When selecting alternative solutions, contract executors need to comprehensively consider the following factors:


  • Medium characteristics (corrosiveness, viscosity, etc.)
  • Pressure range and overload requirements
  • Ambient temperature and protection rating
  • Output signal type and power supply method
  • Installation space limitations

V. Why Choose Xi'an Shenghongchuang Instrumentation


As a high-tech enterprise in a national-level new district, we provide:


  • A professional technical support team, providing full-process guidance from model selection to installation
  • A strict quality control system, ensuring that every piece of equipment leaving the factory achieves the promised performance
  • A comprehensive after-sales service system, providing warranty periods ranging from 1-3 years
  • Customized solutions to meet special operating condition requirements

If you need to obtain the detailed dimensional drawing or technical consultation for the LDN-LDN210 pressure transmitter, please feel free to contact our engineering team at any time, and we will wholeheartedly provide you with professional services.

Submit